RAD7 Radon Meter from DURRIDGE, USA
RAD7 Radon Meter from DURRIDGE, USA

RAD7 Radon Meter from DURRIDGE, USA

Category:

Instrumentation/Analytical instruments/Gas analyzer

Model:

XY-700

Brand:

Qingdao Xinye Environmental Protection

brand:

Qingdao Xinye Environmental Protection

model:

XY-700

Item Number:

010012

material:

Details

Installation method:

Portable handheld device

display mode:

Digital Display

Coverage frequency:

Air radon: (2-999999) Bq/m3; Soil radon: (300-999999) Bq/m3; Radon in water: (0.002-999.999) Bq/L; Radon release rate: (0.001-33.000) Bq/

level accuracy:

Background count rate: ≤ 0.01cpm

distortion:

Detection sensitivity: 0.2 cpm/pCi/L

sensitivity:

Detection limit: ≤ 2Bq/m3

weight:

one point two

Specifications:

330 × 210 × 170)mm

Processing & Customization:

yes

Is it imported:

yes

Place of Origin:

Shandong

Retail Price

1,680.00USD


重量

kg

  • Product Description
  • brand

    Qingdao Xinye Environmental Protection

    model

    XY-700

    Item Number

    010012

    material

    Details

    Installation method

    Portable handheld device

    display mode

    Digital Display

    Coverage frequency

    Air radon: (2-999999) Bq/m3; Soil radon: (300-999999) Bq/m3; Radon in water: (0.002-999.999) Bq/L; Radon release rate: (0.001-33.000) Bq/

    level accuracy

    Background count rate: ≤ 0.01cpm

    distortion

    Detection sensitivity: 0.2 cpm/pCi/L

    sensitivity

    Detection limit: ≤ 2Bq/m3

    weight

    one point two

    Specifications

    330 × 210 × 170)mm

    Processing & Customization

    yes

    Is it imported

    yes

    Place of Origin

    Shandong

    Description :

      DURRIDGE RAD7 Radon Meter from the United States

      

      the United States DURRIDGE RADseven Radon detector

      The DURRIDGE RAD7 radon meter from the United States can not only measure radon in the air, but can also be equipped with RAD H2O and RAD AQUA radon accessories to measure radon in water. The SOIL PROBE soil probe can be used to measure radon in soil, and the SOIL COVER can be used to measure surface radon. the United States

      The DURRIDGE RAD7 radon detector has obtained the National Type Approval Certificate for Measuring Instruments, with type approval number PA 2006-C262.

      The portable radon detector RAD7 is a handheld radon continuous monitoring device produced by DURRIDGE in the United States. It can not only measure the concentration of radon in the air, but also

      Radon, optional soil and water probes can simultaneously measure radon in water and soil. The following is a detailed introduction, standard configuration list, and optional accessories for radon detectors.

      The RAD7 alpha spectrum radon detector from DURRIDGE Corporation in the United States is a handheld detector with the shortest response and recovery time, sniffing and continuous operation on the market. Easy to operate, follow the prompts of the microcomputer to display the measured radon and thorium gas concentrations in frequency spectrum curves, and output data using an infrared printer. By using a drying device to reduce the humidity of the sampled air, the accuracy of the detection results can be improved. You can set the sound emitted when counting radon and thorium gas to understand high pollution areas. Multiple accessory options are available for measuring radon in the air, soil, and water.

      It only takes one hour to measure the 4pCi/L action level concentration specified by the US EPA.

      According to the Metrology Law and relevant regulations and technical requirements, the RAD7 electronic radon meter from DURRIDGE Company in the United States has been tested

      Qualified identification and obtain the type approval certificate for the measuring instrument. Type approval number PA 2006-C262.

      Features of DURRIDGE RAD7 Radon Meter from the United States

      The electronic radon detector with the fastest response and shortest recovery time is a portable detector that integrates continuous monitoring of radon gas and detection of radon radiation sources

      Easy to operate, follow the prompts of the microcomputer to display the measured radon and thorium in spectral curves, and can output data using an infrared printer. Multiple measurements can be taken, including radon in the air, radon in water, and radon in soil

      Provide fast and highly sensitive readings (0.5cpm/pCi/L)

      Compliant with the 1-hour 4pCi/L operating standard set by the US EPA

      By using a drying device to reduce the humidity of the sampled air, the accuracy of the detection results can be improved

      The test results can be displayed, printed out, and downloaded on a computer

      Lightweight and durable, equipped with a sturdy portable case, built-in sampling pump, RS-232 and USB serial ports, data download and analysis software

      Standard configuration of DURRIDGE RAD7 radon detector in the United States:

      RAD-7 host, power cord, shoulder strap and key, printer, 3 rolls of printing paper, printer adapter, 6 air intake filters, 1 dust filter

      Device, 3 ethylene resin tubes, large drying tube, small drying tube, desiccant, built-in charging battery, PC data software and computer connection cable, Chinese and English user manual.

      Optional accessories:

      RAD AQUA Continuous Water Radon Accessories

      By continuously pumping water samples into the RAD AQUA reaction chamber using a pump, radon gas will be released from the water, and with the help of RAD7, the radon concentration in the water can be continuously monitored. This device has very high sensitivity and low detection limit. By selecting remote accessories, users can even monitor and download readings in real-time from a distance.

      RAD H2O water radon gas accessories

      Collect water samples using 40ml or 250ml glass bottles, and use RAD7 to select the appropriate measurement protocol. The instrument will automatically run and obtain detection results. The sensitivity of 40ml and 250ml bottles is 0.008ppm and 0.05cpm per pCi/L, respectively. Suitable for spot check measurement of radon concentration in water

      Water PROBE water radon detection head

      This is an optional accessory designed for RAD7 to monitor radon concentration at specific water depths in wells, ponds, or rivers. The radon detection head in water is composed of a hose with a semi permeable diaphragm installed on a metal support frame. Especially suitable for environments with long-term static conditions and no water collection pump.

      HS25L High Sensitivity Radon Gas Accessories in Water

      Collect water samples using a 2.5L glass bottle, in conjunction with RAD7, select the sniffing mode measurement protocol, and the instrument will automatically run

      And obtain the detection results. The detection sensitivity can be increased to 0.3cpm per pCi/L, which is suitable for measuring a very low concentration radon gas sample in water in a short period of time

      Soil rod SOIL PROBE

      Insert the soil rod into the soil of the testing site and use RAD7. The built-in pump will extract radon gas from the soil through the soil rod, allowing for continuous monitoring of radon concentration in the soil.

      Radioum PROBE radium detection head, DRYSTIK drying tube moisture converter, Addender range extender, SOIL COVER surface radon detection accessories, etc

      Before starting the measurement, place RAD7 in a dry, radon free atmosphere to clean the instrument's gas path for a period of time. During the cleaning process, use a large laboratory drying cylinder. And small drying rods are used for actual measurement. Connect a filter to the intake port of RAD7 first (refer to RAD7 operation manual),

      Then connect the large drying cylinder to the filter. After cleaning the RAD7 air path in clean and dry air for 10 minutes, press[MENU] (Menu) key, then press twice[ENTER] (Enter the status window with the confirm button and press the right arrow key twice to check the relative humidity. If the relative humidity has not decreased to 6%, clean it for a period of time. In order to achieve effective drying, after the next 10 minutes of air path cleaning, connect the outlet of RAD7 to the inlet end of the drying cylinder to form a closed-loop circuit. This can continuously dry RAD7 without introducing fresh air.

      If RAD7 has not been used for a period of time, or if the rubber hose connecting the air inlet and outlet has been disconnected, it will take longer for the air path to dry, at least 30 minutes or more. Once the drying process is completed, the air path cleaning during each measurement process only takes 10 minutes.

      Product specifications of DURRIDGE RAD7 radon detector in the United States:

      detector

      

      Solid state, ion implanted, planar, silicon detector. Not sensitive to vibrations and noise that plague many other detectors. Only very low background values. If there is no radon gas, the RAD7 radon gas window will not count

      

      Target air

      

      Rn-222 (radon gas); Rn-220 (thorium gas)

      

      Power range

      

      0.1 20000 pCi/L (4 750000 Bq/m3). The detection limit can reach 0.1 pCi/L. Because most readings in air detection are below 1.0 pCi/L, it is particularly useful

      

      sensitivity

      

      Sniffing mode: 0.25 CPM/pCi/L

      Normal mode: 0.5 CPM/pCi/L

      

      built-in pump

      

      Microprocessor control, timed or continuous: 1 liter/minute

      

      energy spectrum

      

      Capable of printing energy spectra displaying characteristic peaks of radon gas and thorium radiation gas. Print the radon concentration that changes over time

      

      recover

      

      Recovery from high radon exposure with a half-life of 3.05 minutes; Recovered to less than 10% of peak value within 12 minutes, recovered to 1% of peak value within 30 minutes, and decreased from 20000 pCi/L to 1 pCi/L within 1 hour

      

      Pre set protocol

      

      Sniffing mode, 1 day, 2 days, week, user-defined, capture, Wat-40, Wat-250, and thorium gas injection

      

      Cycle Time

      

      Set the cycle interval as per your request, from 2 minutes to 24 hours

      

      The data shows

      

      Two lines of 16 character LCD display. Multiple windows and extensive menus

      

      data storage

      

      Store 1000 radon gas measurements, including time, date, temperature, humidity, battery voltage, operating mode, radon and thorium emissions, and statistical uncertainty

      

      output

      

      The RS-232 serial port is used for downloading to a computer. Remote control of RAD7 and/or external relay box control can also be performed using RADLINK software

      

      printer

      

      Wireless printer. Infrared connection, no need to connect. Data, bar charts, and energy spectra can be printed during and after testing

      

      power supply

      

      220V AC power supply: continuous monitoring

      6V 2.5Ah rechargeable battery: 72 hours of operation time per charge

      Optional low-voltage AC/DC input allows for operation and internal battery charging using car charging accessory sockets

      

      environment

      

      Working environment: 0 50oC; 0 100% relative humidity, no frost

      Storage temperature: -40 60 oC

      

      size

      

      9.5 "7.5" 10.5 ", approximately 5kg

      Shell: Highly sealed, high-density shell. RAD7 has passed many drop tests

      

    AfterSalesService :

    Key words: