LH-S900 surfactant online analyzer
Category:
Environmental Protection/Analytical instruments/Water quality online monitoring system
Model:
TN 2131
Brand:
Qingdao Lingheng
model:
TN 2131
Working Voltage:
AC230±10%V,50±10%Hz,5A
measurement accuracy:
Exceeding ± 3% FS
structural style :
cabinet-type
Temperature control range:
+5~28℃
Product Type:
Water Quality Online
Processing & Customization:
yes
power:
two hundred and twenty
weight:
fifty-five
Scope of Application:
Online monitoring of sewage
Place of Origin:
Qingdao
manufacturer:
Qingdao Xinye
Retail Price
19,800.00USD
重量
kg
- Product Description
-
model TN 2131
Working Voltage AC230±10%V,50±10%Hz,5A
measurement accuracy Exceeding ± 3% FS
structural style cabinet-type
Temperature control range +5~28℃
Product Type Water Quality Online
Processing & Customization yes
power two hundred and twenty
weight fifty-five
Scope of Application Online monitoring of sewage
Place of Origin Qingdao
manufacturer Qingdao Xinye
Description :





Qingdao Xinye Environmental Protection Technology Co., Ltd
We are a comprehensive on-site manufacturer that integrates environmental research, design, production, maintenance, and sales.
Qingdao Lingheng Environmental Technology Co., Ltd
Belonging to Jiangsu Lingheng Environmental Technology Co., Ltd. Qingdao Branch, the main business scope is sales and services of online water quality monitoring instruments.
Service commitment:
Putting customer needs first, "today's quality, tomorrow's market, and service forever" is our guiding principle for serving customers at Xinye Environmental Protection Company, and it runs through all aspects of research and development, production, installation, sales, and after-sales service.
The company solemnly promises:
Improve communication and coordination mechanisms:By strengthening communication and exchange, improving the timeliness and accuracy of information transmission, going deep into the market, listening to user voices, and understanding customer instrument and equipment needs.
Our company promises:Complete the production tasks of the supplied products with quality, quantity, and on time, and transport the products to the customer's demand site in a timely manner to ensure normal operation.
Whole process monitoring:Customers only need one phone call, and the after-sales service department adopts a one-stop mode, comprehensive responsibility system, full monitoring and implementation, and tracking of processing results to ensure customer satisfaction.

Product documentation
Measurement method:
The total content of various surfactants in surface water and industrial wastewater was measured by online extraction enrichment and colorimetric analysis, and the measurement results met the Chinese national standards
Measurement range:
(0–0.1/0.5/1/2/5)mg/L, Can cover online monitoring of surface active agents in sewage or surface water discharged from any domestic sewage discharge outlet.
Measurement accuracy:
Accuracy:<10%, far superior to general monitoring instruments, due to the use of our company's calibration technology, which can achieve high accuracy in sampling volume through this algorithm.
Repeatability:<10%, high repeatability is due to the use of unique optical quantification algorithms.
zero drift
± 0.01mg/L
Span Drift
± 10%
MTBF (Time Between Failures)
≥ 720 hours per session
Comparison of actual water samples
±10%
Measuring principle
Online extraction technology enriches colorimetric determination, greatly reducing the detection limit through this technology. The detection limit of conventional methods is 0.2ppm, while the detection limit is reduced to 0.002ppm through online extraction technology
Measurement method:
Multiple options can be implemented, and timed measurement can be used to start the instrument for measurement at any time the user wants to monitor every day; Equal time measurement can automatically start the instrument every few hours at fixed intervals every day for measurement; Continuous measurement can achieve automatic sample measurement one after another, which can be used for product acceptance and related technical certification; Manual measurement can enable users to start measurement at any time on site, and can be used for on-site experimental comparison and equipment installation and debugging.
Measurement time:
It can be set arbitrarily, usually 15 minutes. This technique is used because the time for measuring a sample using the national standard method is fixed, in order to ensure that any water sample can be accurately measured. By setting the reaction time arbitrarily, it ensures that any water sample can obtain accurate monitoring results.
Correction method:
Automatic timed calibration or manual calibration, where the calibration standard solution can be configured and set according to the nearest principle based on the actual surfactant content range of the user's water sample, because the water sample that the user wants to monitor is generally limited to a certain range. By configuring a standard solution that is close to the actual water sample content of the user based on the nearest principle, the instrument can greatly improve the accuracy of measurement.
Reagent consumption:
During each measurement process, only 1mL of each reagent is consumed, and after the measurement is completed, the reagents are discharged into a large capacity recycling container, greatly extending the overall reagent replacement time.
Internal sampling of the instrument:
By using an injection pump, the characteristic of the injection pump compared to a peristaltic pump is that it has a long service life and does not have aging components such as pump tubes. The service life of the injection pump can accompany the instrument for a lifetime, and only the syringe needs to be replaced once a year.
External sampling of instruments:
Two methods are provided: submersible pump and self-priming pump. Generally, submersible pump is used for situations where the drop between the water sample point and the ground is too large (usually more than 2 meters), while self-priming pump is used for situations where the drop between the water sample point and the ground is less than 2 meters.
Maintenance cycle:
If 12 samples are measured daily, the reagents should be replaced every three months; Clean the filter screen of the external sampling pump every three months based on the actual water sample situation; Clean the quantitative tube every six months or choose to replace it.
Preprocessing device:
The preprocessing device will automatically perform flushing and maintenance after each measurement, and it also has a separate control box for manual cleaning and maintenance.
Secondary pollution:
All chemical reagents used are fully recovered and there is no direct discharge to the outside world.
Data transmission:
It can provide multiple data transmission interfaces such as 4-20mA and RS232 simultaneously, and the measurement results can be transmitted to the data acquisition instrument or confidence control center through this interface.
Ambient temperature
+From 5 ° C to+40 ° C, users are required to ensure that the water sample does not freeze at the instrument installation point. In outdoor engineering installations, water pipe insulation should be considered to prevent freezing and blockage of the water pipe in winter.
Mechanical dimensions:
500 mm x 780 mm x 320 mm, During installation, it can be stacked on top of the pre-treatment device on the ground or hung separately on the wall.
Weight:
About 30 kg
Power Supply:
(220±20) VAC /(50±0.5) Hz
power waste:
About 100 W
AfterSalesService :
Key words:- Surface active agent online analyzer