5P explosion-proof air conditioner, 5-pile cabinet explosion-proof air conditioner, 3-horsepower fixed frequency explosion-proof air conditioner, Luoping explosion-proof air conditioner
5P explosion-proof air conditioner, 5-pile cabinet explosion-proof air conditioner, 3-horsepower fixed frequency explosion-proof air conditioner, Luoping explosion-proof air conditioner

5P explosion-proof air conditioner, 5-pile cabinet explosion-proof air conditioner, 3-horsepower fixed frequency explosion-proof air conditioner, Luoping explosion-proof air conditioner

Category:

Electrical Engineering/Air conditioning unit/Explosion proof air conditioning

Model:

BKR

Brand:

Luoping Explosion proof

brand:

Luoping Explosion proof

model:

BKR

type:

Split type cabinet

Temperature range:

10-40

Processing & Customization:

yes

Is it imported:

No

Place of Origin:

Zhejiang

Retail Price

3,003.00USD


重量

kg

  • Product Description
  • brand

    Luoping Explosion proof

    model

    BKR

    type

    Split type cabinet

    Temperature range

    10-40

    Processing & Customization

    yes

    Is it imported

    No

    Place of Origin

    Zhejiang

    Description :

      Explosion proof air conditioner 5P cabinet type heating and cooling explosion-proof air conditioner 12kW cooling capacity 12000W explosion-proof vertical air conditioner

      Whether in winter or summer, air conditioning seems to have become an indispensable necessity in daily life. The office, various large and small shopping malls, shops, etc. have air conditioning running day and night. So, what about the workshop? The workshop is an important place for production activities, and installing air conditioning is of utmost importance.

      So why can explosion-proof air conditioning play an explosion-proof role?

      Explosion proof air conditioning is mainly due to the placement of aluminum alloy explosion suppression materials in it, and the mesh in this material layer will form a honeycomb structure, thereby dividing the container cavity into many "small compartments". These "small compartments" can effectively contain the spread of flames, thus playing a good role in insulation and ensuring safety to a certain extent. At the same time, this honeycomb structure has high surface efficiency per unit volume, thus having good thermal conductivity. It can quickly absorb most of the heat released from combustion, greatly reducing the final temperature Tf after combustion reaction, greatly reducing the expansion degree of reaction gas, and not increasing the pressure value of the container.

      The main locations for the use of explosion-proof air conditioning are

      1. In flammable and explosive environments such as PetroChina, chemical and pharmaceutical industries, and warehousing, IIA and IIB explosion-proof air conditioners can be used;

      2. In environments with flammable and explosive gases such as hydrogen and acetylene, Type IIC explosion-proof air conditioning can be used;

      3. Explosion proof air conditioning must also be used in other special environments such as mining.

      4. Explosion proof air conditioning is occasionally required in shopping malls, shops, and offices

      Explosion proof air conditioning also has requirements for the site in different usage environments

      1. With the rapid development of electronic technology, the functions of electronic devices are becoming stronger and the operating speed is also getting faster, while the cabinet volume of explosion-proof air conditioning design is becoming smaller and smaller. Therefore, the arrangement of electronic components inside the cabinet is becoming increasingly dense, and the heat dissipation per unit volume of the cabinet is increasing. If these heat are discharged in a timely manner, it will cause the temperature of the electronic components themselves and the surrounding environment to gradually increase, thereby shortening the service life of the explosion-proof air conditioner. When the temperature around the components exceeds 65 ℃, the equipment is likely to malfunction. So, try not to use explosion-proof air conditioning at excessively high temperatures. 2. Explosion proof air conditioning not only requires temperature, but also has certain requirements for humidity. If the relative humidity is too low, strong static electricity will be generated in the computer room, which can cause the operation failure of explosion-proof air conditioning. Therefore, the humidity inside the explosion-proof air conditioning room should be controlled between 45% and 65%. Precautions for installation and maintenance of explosion-proof air conditioning

      ① Explosion proof air conditioning installation is not qualified and maintenance is not timely. The installation of the air conditioner does not comply with regulations, which may result in accidents. The metal casing of electrical equipment such as air conditioners does not have a grounding device. Although there is a grounding device, the resistance is too high or the grounding wire and terminal block do not need to be securely connected or welded together; Randomly changing power cords, wiring or insulation wires with broken skin, exposing live parts of air conditioners; Using unqualified electrical products (such as connecting wires and sockets) for installation; The installation personnel are not electricians or lack electrical safety knowledge.

      Not understanding the technical requirements of electrical installation can lead to poor installation quality, poor maintenance and repair, and cause hidden dangers or dangers. Electric shock accidents may occur Electrical equipment, including circuits, air conditioners, switches, sockets, etc., can experience insulation aging, switch failure, and even component damage over time. If not repaired or replaced in a timely manner, continued use can often lead to accidents.

      ② Lack of safety awareness in work. Some electricians are careless and lack a strong sense of responsibility in their work, and do not strictly follow safety operating procedures, resulting in electric shock. For example, when working on equipment such as circuits or air conditioners, starting repairs without conducting electrical checks; Or when repairing an air conditioner, if the power light on the air conditioner does not light up, it may be assumed that the power has been cut off, and if the repair is carried out by pressing the power-off operation, an electric shock accident may occur

      The explosion-proof air conditioning series models can be used in flammable and explosive mixed gas environments such as petroleum, chemical, pharmaceutical, and scientific hazardous warehouses. In terms of structure, composite explosion-proof technologies such as explosion-proof, intrinsic safety, and sealing are adopted. The control end is fully controlled by intrinsic safety, which does not generate any electric sparks and is convenient and safe to use. A multi fin heat exchanger is used, and the contact between the cold coal and the air is more complete when passing through, which can greatly improve the cooling and heating effect of the air conditioner. There are two types of manual control. Explosion proof air conditioners cannot be produced or sold without obtaining an explosion-proof certificate. Explosion proof air conditioning is processed through special explosion-proof technology and widely used in hazardous areas such as national defense, scientific research, petroleum, chemical, pharmaceutical, processing and manufacturing, and biology where flammable gases, vapors, and air from T1 to T4 groups are easily generated. It is a special temperature control air conditioning equipment designed for places with temperature control requirements.

      The execution standards for this series of products are as follows:

      All series products have passed the inspection of the National Explosion proof Electrical Product Quality Supervision and Testing Center and obtained the National Explosion proof Electrical Equipment Explosion proof Certificate: Explosion proof Air Conditioner; Its appearance is beautiful, the design is reasonable, and it has the characteristics of easy installation and maintenance. The entire series of explosion-proof products adopts compressors, microcomputer control, and digital display inside, which have the advantages of low noise, stable performance, and easy operation. Highly favored by customers in various industries, and partially listed in the designated procurement directory of the industry.

      The explosion-proof air conditioning series models produced by our company are processed through special explosion-proof technology and widely used in hazardous areas such as national defense, scientific research, petroleum, chemical, medical, processing and manufacturing, laboratories, substations, warehouses, etc. where flammable gases, vapors, and air are mixed with T1-T4 groups, which can easily cause explosions. They are special temperature control air conditioning equipment designed for places with temperature control requirements.

      Strive for perfection in service

      Zhejiang Luoping Explosion proof Factory can quickly respond and dispatch staff to provide on-site services; Establishing a strong service system to provide customers with thoughtful and fast services has always been the direction that Luoping has been striving for.

      Zhejiang Luoping Explosion proof Manufacturer will continue to produce high-quality products, continuously innovate technology, optimize and improve service systems, and strive to become a benchmark in the field of explosion prevention, temperature control, and humidity control.

    AfterSalesService :

    Key words:
    • 5P explosion-proof air conditioner