D1 class high-energy data lightning arrester bus surge protector line lightning arrester safety lightning protection equipment
D1 class high-energy data lightning arrester bus surge protector line lightning arrester safety lightning protection equipment

D1 class high-energy data lightning arrester bus surge protector line lightning arrester safety lightning protection equipment

Category:

mechanical equipment/High voltage electrical appliances/Lightning protection and lightning protection products

Model:

AS24Y-D1

Brand:

Anxin Lightning Protection

model:

AS24Y-D1

type:

Varistor/gas discharge combination lightning arrester

voltage level:

high pressure

Protective nature:

Switch type

Installation type:

parallel connection

Processing & Customization:

yes

Product Certification:

Type test report that meets national standards

Place of Origin:

Shenzhen

manufacturer:

Guangdong Anxin Lightning Protection Technology Co., Ltd

Retail Price

880.00USD


重量

kg

  • Product Description
  • model

    AS24Y-D1

    type

    Varistor/gas discharge combination lightning arrester

    voltage level

    high pressure

    Protective nature

    Switch type

    Installation type

    parallel connection

    Processing & Customization

    yes

    Product Certification

    Type test report that meets national standards

    Place of Origin

    Shenzhen

    manufacturer

    Guangdong Anxin Lightning Protection Technology Co., Ltd

    Description :

      D1 surge protector, d1 high-energy test type spd

    D1类电涌保护器,d1类高能量试验类型的spd

      Installation and wiring:

      ·The D1 type surge protector is installed on a 35mm standard rail;

      ·The wiring method for D1 type surge protectors is series connection; Either end of the PE terminal at both ends of the lightning arrester is grounded;

      ·The output terminal (OUT) of Class D1 surge protector should be connected to the protected equipment as close as possible, and should not be connected in reverse;

      ·During installation, the two ends of the circuit must be laid separately and cannot be tied together to prevent secondary induction;

      ·Connect the grounding wire of the D1 type surge protector reliably to the grounding busbar of the lightning protection system. The grounding wire should be as short, thick, and straight as possible to shorten the lightning current path as much as possible;

      ·After completing the installation and wiring, check that the wiring is correct and secure, and then connect the power to put it into use.

      Detailed parameters:

      

    AfterSalesService :

    Key words:
    • Data lightning arrester