JH-3011A portable CO analyzer non dispersive infrared CO analyzer
Category:
Instrumentation/Gas analyzer/Carbon monoxide detector
Model:
JH-3010/3011AE
Brand:
Jingcheng Instrument
model:
JH-3010/3011AE
measurement range:
0.001-50
measurement object:
carbon monoxide
measurement accuracy:
zero point zero zero one
resolution:
zero point zero zero one
power supply:
two hundred and twenty
voltage:
two hundred and twenty
Shell material:
one
Protection level:
one
Explosion-proof rating:
one
Processing & Customization:
yes
weight:
three
manufacturer:
Qingdao Jingcheng
Retail Price
16,500.00USD
重量
kg
- Product Description
-
model JH-3010/3011AE
measurement range 0.001-50
measurement object carbon monoxide
measurement accuracy zero point zero zero one
resolution zero point zero zero one
power supply two hundred and twenty
voltage two hundred and twenty
Shell material one
Protection level one
Explosion-proof rating one
Processing & Customization yes
weight three
manufacturer Qingdao Jingcheng
Description :
1、 Overview of JH-3011A Portable Infrared CO Analyzer:
This instrument complies with the national standards of GB/T18204.2-2014 "Methods for hygiene inspection in public places" and GB/T9801-88 "Determination of air quality - Non dispersive infrared method"; Complies with the metrological verification regulations of JJG635-2011 "Carbon Dioxide Infrared Gas Analyzer".
The main technical indicators of this instrument meet the technical requirements of China's secondary instruments
This instrument has a built-in zero adjustment filter and a six way valve for switching between zero adjustment and measurement, making it easy and flexible to operate.
This instrument can customize the measurement range.
2、 Main technical specifications of JH-3011A portable infrared CO analyzer:
Measurement principle: Non dispersive infrared analysis method/Non dispersive infrared method (NDIR);
Sampling method: built-in pump suction;
Measurement range: 0-50.0 × 10-6 or 0-200.0 × 10-6;
Resolution: 0.1 × 10-6;
Repeatability: ≤ 1% F · S;
Zero drift: ≤± 2% F · S/h;
Span drift: ≤± 2% F · S/3h;
Linear deviation: ≤± 2% F · S;
Response time: t0~t90 ≤ 45S;
Preheating time: ≤ 30 minutes;
Flow range: (0.5-2.0) L/min;
Standard configuration: host, sampler, rechargeable battery, charger, technical documents, portable case;
Power supply: AC/DC dual-use, 220C (± 10%) or built-in rechargeable battery;
Dimensions: 245 × 190 × 85 (mm);
Weight: ≤ 3kg.
AfterSalesService :
Key words:- CO analyzer
More Products