Total Manganese Online Analyzer, Water Quality, Heavy Metal Online Monitoring, Wastewater, Manganese Ion Online Real time Detection
Total Manganese Online Analyzer, Water Quality, Heavy Metal Online Monitoring, Wastewater, Manganese Ion Online Real time Detection

Total Manganese Online Analyzer, Water Quality, Heavy Metal Online Monitoring, Wastewater, Manganese Ion Online Real time Detection

Category:

Environmental Protection/Analytical instruments/Water quality online monitoring system

Model:

SZ-Mn

Brand:

Jingcheng Instrument

model:

SZ-Mn

Working Voltage:

AC230±10%V

measurement accuracy:

± 5% or ± 0.1mg/L (whichever is greater)

structural style :

cabinet-type

Temperature control range:

Suggested temperature: 15-25 ℃

Product Type:

Online instruments

Processing & Customization:

No

weight:

fifty

Scope of Application:

0—15mg/L

Place of Origin:

Qingdao

manufacturer:

Qingdao Jingcheng

Retail Price

20,000.00USD


重量

kg

  • Product Description
  • model

    SZ-Mn

    Working Voltage

    AC230±10%V

    measurement accuracy

    ± 5% or ± 0.1mg/L (whichever is greater)

    structural style

    cabinet-type

    Temperature control range

    Suggested temperature: 15-25 ℃

    Product Type

    Online instruments

    Processing & Customization

    No

    weight

    fifty

    Scope of Application

    0—15mg/L

    Place of Origin

    Qingdao

    manufacturer

    Qingdao Jingcheng

    Description :

      Total Manganese Online Analyzer

      Manganese ion detection

      1、 Product Overview of Total Manganese Online Analyzer:

      Manganese is a gray white, hard, brittle, and glossy metal that is widely present in nature. Soil contains 0.25% manganese, and tea, wheat, and hard shelled fruits contain more manganese. Used in the metallurgical industry to manufacture special steel; Manganese titanium alloy is used as a desulfurizer and deoxidizer in steel production. Manganese is one of the essential trace elements for a normal body, and it constitutes several enzymes with important physiological functions in the body. The normal daily intake of manganese from food is 3-9 milligrams, which is necessary for normal bone structure. Occupational chronic manganese poisoning is a disease mainly caused by neurological changes due to long-term exposure to manganese dust. Early manifestations include neurasthenia syndrome and autonomic nervous system dysfunction. The more obvious poisoning is the occurrence of extravertebral system damage, which may be accompanied by psychological symptoms. In severe cases, it can manifest as Parkinson's syndrome and toxic psychosis.

      24-hour real-time monitoring

      2、 Product principle of total manganese online analyzer:

      This product is measured using spectrophotometry. After mixing the water sample and buffer, manganese is converted into its high valence state ions in the presence of a strong oxidant. In the presence of a buffer solution and indicator, the high valence ions react with the indicator to form a colored complex. The analyzer detects this color change and converts it into manganese value output. The amount of colored complex generated is equivalent to the manganese content. This product is a single factor parameter testing and analysis instrument. This method is applicable to wastewater containing manganese in the range of 0-30mg/L.

      Heavy metal analysis

      3、 Technical parameters of total manganese online analyzer:

      Specification Name

      

      Technical specifications and parameters

      

      measurement range

      

      0—15mg/L

      

      measurement method

      

      Potassium periodate oxidation spectrophotometric method

      

      detection limit

      

      0.05mg/L

      

      resolution

      

      zero point zero zero one

      

      accuracy

      

      ± 5% or ± 0.1mg/L (whichever is greater)

      

      repetitiveness

      

      ± 5% or ± 0.1mg/L (whichever is greater)

      

      zero drift

      

      ±1mg/L

      

      Span Drift

      

      ±10%

      

      measurement period

      

      The small measurement cycle is 20 minutes, and the digestion time can be set between 5-60 minutes

      

      sampling period

      

      Interval, hourly, and trigger modes can be adjusted

      

      calibration cycle

      

      Automatic calibration 1-99 days adjustable

      

      maintenance cycle

      

      Over 1 month, approximately 1 hour per session

      

      Human machine operation

      

      Touch screen display and command input

      

      Self checking protection

      

      Abnormal or power outage data not lost

      

      After abnormal reset or power outage, residual liquid will be automatically eliminated and work will resume

      

      data storage

      

      1 year of data storage

      

      input interface

      

      discrete signal

      

      output interface

      

      1 RS232 channel; Route 1 4-20mA

      

      working environment

      

      Suggested temperature: 15-25 ℃

      

      Operating Humidity

      

      ≤ 90% (non condensing)

      

      Power Supply and Power

      

      AC230±10%V;50—60Hz,5A

      

      size

      

      1500*550*450mm

      Water Quality Monitor

      

    AfterSalesService :

    Key words:
    • Total Manganese Online Analyzer