Total Nickel Online Analyzer Cabinet style Water Quality Heavy Metal Online Real time Monitoring Nickel Ion Concentration Detection
Total Nickel Online Analyzer Cabinet style Water Quality Heavy Metal Online Real time Monitoring Nickel Ion Concentration Detection

Total Nickel Online Analyzer Cabinet style Water Quality Heavy Metal Online Real time Monitoring Nickel Ion Concentration Detection

Category:

Environmental Protection/Analytical instruments/Water quality online monitoring system

Model:

SZ-Ni

Brand:

Jingcheng Instrument

model:

SZ-Ni

Working Voltage:

AC230±10%

measurement accuracy:

± 5% or ± 0.1mg/L (whichever is greater)

structural style :

cabinet-type

Temperature control range:

Suggested temperature: 15-25 ℃

Product Type:

Online instruments

Processing & Customization:

No

weight:

fifty

Scope of Application:

0—15mg/L 1—20mg/L

Place of Origin:

Qingdao

manufacturer:

Qingdao Jingcheng

Retail Price

22,000.00USD


重量

kg

  • Product Description
  • model

    SZ-Ni

    Working Voltage

    AC230±10%

    measurement accuracy

    ± 5% or ± 0.1mg/L (whichever is greater)

    structural style

    cabinet-type

    Temperature control range

    Suggested temperature: 15-25 ℃

    Product Type

    Online instruments

    Processing & Customization

    No

    weight

    fifty

    Scope of Application

    0—15mg/L 1—20mg/L

    Place of Origin

    Qingdao

    manufacturer

    Qingdao Jingcheng

    Description :

      Total Nickel Online Analyzer

      Heavy metal detector

      1、 Product Overview of Total Nickel Online Analyzer:

      Nickel is a silver white metal, a hard and brittle metal that is stable in the air at room temperature and is an inactive element. Nickel is prone to interact with liusuan and may be present in dilute wastewater from chemical, ceramic, and glass industries.

      This analyzer is capable of long-term automatic continuous operation according to on-site settings, and is widely applicable to industrial pollution source discharge wastewater, industrial process wastewater, industrial wastewater treatment plant wastewater, municipal wastewater treatment plant wastewater, and other occasions. According to the complexity of the on-site testing conditions, corresponding preprocessing systems can be selected to ensure the reliability of the testing process, accurate testing results, and fully meet the on-site requirements of different occasions.

      Total nickel detector

      2、 Product principle of total nickel online analyzer:

      This product is measured using spectrophotometry. After mixing the water sample and buffer, nickel is converted into its high valence state ions in the presence of a strong oxidant. In the presence of a buffer solution and indicator, the high valence state ions react with the indicator to form a colored complex. The analyzer detects the color change and converts it into a nickel value output. The amount of colored complex generated is equivalent to the nickel content. This product is a single factor parameter testing and analysis instrument. This method is applicable to wastewater containing nickel in the range of 0-20mg/L.

      Online total nickel monitoring device

      3、 Technical parameters of total nickel online analyzer:

      Specification Name

      

      Technical specifications and parameters

      

      measurement range

      (switchable)

      

      0—15mg/L

      

      1—20mg/L

      

      measurement method

      

      Dimethylglyoxime spectrophotometric method

      

      detection limit

      

      0.001mg/L

      

      resolution

      

      zero point zero zero one

      

      accuracy

      

      ± 5% or ± 0.1mg/L (whichever is greater)

      

      repetitiveness

      

      ± 5% or ± 0.1mg/L (whichever is greater)

      

      zero drift

      

      ±5%

      

      Span Drift

      

      ±10%

      

      measurement period

      

      The small measurement cycle is 20 minutes, and the digestion time can be set between 5-60 minutes

      

      sampling period

      

      Interval, hourly, and trigger modes can be adjusted

      

      calibration cycle

      

      Automatic calibration 1-99 days adjustable

      

      maintenance cycle

      

      Over 1 month, approximately 1 hour per session

      

      Human machine operation

      

      Touch screen display and command input

      

      Self checking protection

      

      Abnormal or power outage data not lost

      

      After abnormal reset or power outage, residual liquid will be automatically eliminated and work will resume

      

      data storage

      

      1 year of data storage

      

      output interface

      

      1 RS232 channel; Route 1 4-20mA

      

      working environment

      

      Suggested temperature: 15-25 ℃

      

      Operating Humidity

      

      ≤ 90% (non condensing)

      

      Power Supply and Power

      

      AC230±10%V;50—60Hz,5A

      

      size

      

      1500*550*450mm

      

      Water Quality Analyzer

    AfterSalesService :

    Key words:
    • Total Nickel Online Analyzer