Microwave digestion analyzer manufacturer Qingdao Lubo
Category:
Instrumentation/Environmental testing instruments/Other environmental testing instruments
Model:
LB-XJ02
Brand:
Qingdao Road Expo
model:
LB-XJ02
measurement object:
Sample digestion
measurement range:
0-40°C
measurement accuracy:
:±0.1℃
Processing & Customization:
yes
weight:
About 35
Place of Origin:
Qingdao
manufacturer:
Qingdao Road Expo
Retail Price
718,599.00USD
重量
kg
- Product Description
-
model LB-XJ02
measurement object Sample digestion
measurement range 0-40°C
measurement accuracy :±0.1℃
Processing & Customization yes
weight About 35
Place of Origin Qingdao
manufacturer Qingdao Road Expo
Description :
microwave digestion ceremony
one working conditions
1.1 Power Supply: AC 220V+/-10%, 50/60Hz
Environmental temperature: 0-40 ° C
Environmental humidity:<85%
two Technical Requirements
2.1 Microwave System
2.1.1 Microwave power 0-1200W, automatically continuously adjustable; By using a magnetron, the microwave inside the furnace cavity can be ensured to be uniform, and the instrument can work stably for a long time;
2.1.2 Microwave input power ≥ 1600W; Microwave output power ≥ 1200W
2.1.3 Microwave frequency: 2450MHz
*2.1.4 Uniformity: The unidirectional 360 ° coaxial and uniform rotation of the turntable makes the sample more evenly heated in a microwave environment, greatly increasing the precision of the instrument, the consistency of sample digestion and detection, and reducing the impact on the turntable motor, thereby extending its service life.;
2.2 Furnace cavity system
*2.2.1 The large volume resonant cavity is made of austenitic non-magnetic stainless steel material, laser full welding, no leakage, no ignition, and the cavity volume is ≥45L,Surface treated with 5 layers of Teflon spray coating,Has good corrosion resistance and microwave reflection performance; Multi flux sample processing, simultaneously processing up tosixSamples can also be processed separately-sixA sampleIn the later stage, it can be upgraded to8 or 10 digits;
2.2.2 Specially designed dual protection safety furnace door, multi-layer composite integrated high-strength anti radiation leakage furnace door, explosion-proof, shock wave resistant, microwave leakage prevention and other safety performance;
2.3 Temperature and pressure control system
*2.3.1 Adopting high-precision PTone000Contact temperature sensor, detection frequency: 150-200 data/second;Rate of warming:Reach the target temperature at a constant speed within the set time. Temperature sensor range: 0-300 ℃; Temperature measurement accuracy: ± 0.1 ℃; Temperature control accuracy ± 1 ℃;
*2.3.2 High precision contact pressure sensors are used to measure the actual pressure of the reactants, rather than calculated values such as water line pressure measurement, and to avoid the influence of errors caused by piezoelectric crystal pressure measurement methods and internal tank shape changes;Pressure sensor range: 0-10MPa; Pressure control range: 0~tenMPa; Measurement accuracy ≤ ± 0.01Mpa; The precision of pressure control is ≤± 0.05Mpa.
two point four Multi flux digestion rotor:
*2.4.1 The pressure resistant jacket is made of fully imported high-strength aerospace composite material PEEK, which is die cast as a whole and can withstand high temperature and high pressure; Operating Temperature≥2five0℃Work pressure≥fiveMpa;
*2.4.2 The tank rack adopts a petal shaped frame structure, which is injection molded from composite materials and has strong pressure bearing capacity; Equipped with 10 digestion rotors for easy loading and unloading; The digestion process does not require any consumables;
2.4.3 The inner tank is made of molded modified polytetrafluoroethylene material, which has good density and good safety performance without micropores; Good mechanical properties and creep resistance, the sample can be directly weighed on a balance without the need for transfer steps;
2.4.4 Explosion proof design: Vertical directional blasting design of the tank body to avoid lateral impact;
two point fiveCooling system:
2.5.1 Cooling method: Forced rapid air cooling inside the furnace chamber, using corrosion-resistant, high air volume centrifugal fans with an exhaust volume of ≥ 4M3/min. After the reaction is complete, the microwave stops emitting, and the turntable and fan continue to work. After the temperature inside the tank cools to 40 ℃, the instrument automatically beeps to remind;
2.6 Software Control System
*2.6.1Equipped with AndroidoperationsystemfiveInch color LCD capacitive touch screen, quad core 1.2GHz processor,oneGB of running memory,eightG memory, USB interface, real-time display of temperature, time, microwave power, pressure values and curve graphs in the reaction system. The instrument can be set up in 20 reaction stages step by step, and there is no limit to storing reaction data sets;
*2.6.2Randomly equipped with upper computer software for replaying experimental data, it can be connected to the PC upper computer in real time through a local area network (WiFi), remotely viewing real-time experimental parameters such as temperature, pressure, microwave power, etc., for easy analysis of experimental results. The software will also alarm for abnormal situations and remotely shut down the instrument. equipped withDevice, inofflineRemote stop of response in emergency situations;
three Requirements for accessories (attachments)
name
quantity
name
quantity
host
1 (unit)
Pressure measuring tube assembly
2 sets
High precision platinum plated temperature sensor PT1000
1 (piece)
250V/10A tube
2 sets
6-digit turntable
1 (set)
Electric torque wrench
1 (Deputy)
Cup style outer tank (including one set of main tank)
6 sets
Pressure sensor assembly
1 (piece)
Dissolve inner tank (including one set of main tank)
6 sets
1 (piece)
100ml digestion tank rack
6 sets
Peek gasket
6 (pieces)
set screw
6 (pieces)
User Guide
1 (Ben)
Certificate of Conformity
1 (sheet)
AfterSalesService :