Manufacturer of opaque smoke meter Qingdao Lubo
Category:
auto parts/Automobile and motorcycle testing equipment/Exhaust gas/exhaust gas analyzer
Model:
Handset Smoke
Brand:
Qingdao Lubo Jianye Environmental Protection Techn
model:
Handset Smoke
display mode:
LCD (Liquid Crystal Display)
measurement object:
See details
measurement range:
See details
precision:
See details
resolution:
See details
response time:
See details
output interface:
See details
power:
Maximum 65W
power supply:
two hundred and twenty
Processing & Customization:
yes
weight:
&5kg (excluding battery)? 7kg (including battery)
Place of Origin:
Qingdao
manufacturer:
Qingdao Road Expo
Retail Price
666.00USD
重量
kg
- Product Description
-
model Handset Smoke
display mode LCD (Liquid Crystal Display)
measurement object See details
measurement range See details
precision See details
resolution See details
response time See details
output interface See details
power Maximum 65W
power supply two hundred and twenty
Processing & Customization yes
weight &5kg (excluding battery)? 7kg (including battery)
Place of Origin Qingdao
manufacturer Qingdao Road Expo
Description :
Direct supply from Qingdao Lubo manufacturer, with years of research and development and excellent technology. Welcome to inquire by phone, contact Fu Yajian
Principle of opaque smoke meter detection: China has always used filter paper smoke meters to measure the smoke level of diesel vehicles at full load and free acceleration. In order to align emission standards with international standards, the emission standards implemented since 2000 introduced the concept of opaque smoke, which measures the amount of visible pollutants using the light absorption coefficient. It is stipulated that during full load stable speed tests and free acceleration tests, opaque smoke meters are used to measure visible pollutants in the exhaust of compression ignition engines and vehicles equipped with compression ignition engines.
Handset Smoke Opaque Smoke Meter


Technical Specifications:
Measure the effective length of the gas chamber
215mm±0.05cm
measurement range
N value of opacity
0-100%
0.01%
Extinction coefficient K value
0-16.00m-1
0.01m-1
Engine RPM (optional)
400 -9,999
10rpm
Oil Temperature (optional)
-13-+150℃
1℃
warm-up time
3-6 minutes (depending on ambient temperature)
Zero point calibration and calibration before use
Equipped with 50% electronic filter automatic calibration function
General working environment temperature range
+5 ℃ -+40 ℃ (customizable for special weather conditions)
humidity
30% - 90%.
Storage temperature
-32℃- +55℃
Temperature of the tested gas
0-256℃
Physical response time
When T10% -90% sample gas flow rate is 75L/minute, less than 0.2 seconds
Electrical response time
0.9 seconds
power consumption
65W
host weight
&5kg (excluding battery)? 7kg (including battery)
AfterSalesService :
Key words:- Opaque smoke meter