The online water quality sampler manufacturer has complete direct supply certificates
The online water quality sampler manufacturer has complete direct supply certificates

The online water quality sampler manufacturer has complete direct supply certificates

Category:

Environmental Protection/Analytical instruments/water sampler

Model:

LB-8000K

Brand:

Qingdao Lubo Jianye Environmental Protection Techn

model:

LB-8000K

type:

water sampler

Sampling flow range:

( 2~9999) min

weight:

sixty

material:

See details

Pipe diameter and material thickness:

See details

Processing & Customization:

No

display mode:

See details

Continuous working hours:

See details

power supply voltage:

two hundred and twenty

ambient temperature:

See details

ambient humidity:

See details

Is it waterproof:

No

noise:

See details

Overall dimensions:

See details

Place of Origin:

Qingdao

manufacturer:

Qingdao Road Expo

Retail Price

88.00USD


重量

kg

  • Product Description
  • model

    LB-8000K

    type

    water sampler

    Sampling flow range

    ( 2~9999) min

    weight

    sixty

    material

    See details

    Pipe diameter and material thickness

    See details

    Processing & Customization

    No

    display mode

    See details

    Continuous working hours

    See details

    power supply voltage

    two hundred and twenty

    ambient temperature

    See details

    ambient humidity

    See details

    Is it waterproof

    No

    noise

    See details

    Overall dimensions

    See details

    Place of Origin

    Qingdao

    manufacturer

    Qingdao Road Expo

    Description :

      LB-8000K online water quality AB bucket automatic sampler

      Sampling bottle

      

      1000ml x 24 bottles

      

      Single sampling quantity

      

      (5~1000)ml

      

      sampling interval

      

      (2~9999)min

      

      Sampling record

      

      1000 items

      

      Sampling quantity error

      

      ±7%

      

      Proportional sampling error

      

      ±8%

      

      System clock time control error

      

      Δ1≤0.1% Δ12≤30s

      

      temperature control accuracy

      

      1.5℃

      

      Sampling vertical height

      

      ≥8m

      

      Horizontal sampling distance

      

      ≥80m

      

      communication interface

      

      RS-232/RS-485

      

      simulated interface

      

      4mA~20mA

      

      Digital input interface

      

      discrete signal

      

      Sampling precautions 2:

      ① When packaging samples, they must be rinsed three times with water samples before sampling. The water sample used for washing should be discarded. To eliminate potential contamination. But the container for oil extraction cannot be flushed.

      ② The water sample used for measuring turbidity, suspended solids, etc. should be released from the sampler as soon as possible after collection. The sampler should be shaken while bottling to prevent suspended solids from settling inside the sampler. Non representative impurities such as leaves, rods, etc. should be removed from the sample.

      ③ During sampling, measures should be taken to prevent pollution caused by dust falling in the atmosphere at the sampling site. During sampling, vigorous agitation of the water body should be avoided, and agitation of the sediment should be avoided at all times. When manually collecting surface water samples using plastic buckets or sample bottles, the mouth of the sampling container should face the direction of the water flow.

      ④ When the capacity of the water sampler is limited and cannot complete sampling in one go, multiple samplings can be carried out. The collected water samples from each collection can be collected in a clean large container (glass bottle or polyethylene bucket with a capacity greater than 5L). The sample should be shaken thoroughly during packaging. Attention: Mixed samples are not suitable for measuring biochemical oxygen demand, oils, bacteriological indicators, sulfides, and other items with special requirements.

      ⑤ The water sample for measuring biochemical oxygen demand, pH value and other items must be filled with sample bottles during sampling to avoid interference from residual air on the measured items. Sample bottles for measuring other items should be filled with at least 10% of the container volume of water sample (or after sampling), and can generally be placed at the shoulder of the bottle to ensure sufficient shaking of the sample before analysis.

      ⑥ When packaging samples and adding preservatives, precautions should be taken to prevent possible contamination of the samples by the operating environment, especially for samples used to measure microbial substances. Special attention should be paid to prevent contamination of the sample bottle stopper (or cap). ⑦ All items that require on-site testing should be tested on-site.

    AfterSalesService :

    Key words: