Shandong Qingdao nucleic acid sampling workstation manufacturer
Category:
Instrumentation/Environmental testing instruments/Other environmental testing instruments
Model:
LB-3315
Brand:
Qingdao Lubo Jianye Environmental Protection Techn
model:
LB-3315
measurement object:
See details
measurement range:
See details
measurement accuracy:
See details
Processing & Customization:
yes
Overall dimensions:
2000mm*1300mm*2000mm
weight:
About 350
Place of Origin:
Qingdao
manufacturer:
Qingdao Road Expo
Retail Price
22,222.00USD
重量
kg
- Product Description
-
model LB-3315
measurement object See details
measurement range See details
measurement accuracy See details
Processing & Customization yes
Overall dimensions 2000mm*1300mm*2000mm
weight About 350
Place of Origin Qingdao
manufacturer Qingdao Road Expo
Description :
Manufacturer of nucleic acid sampling workstation
Shandong Qingdao nucleic acid testSampling workstation manufacturer
Shandong Qingdao nucleic acid testSampling workstation manufacturer
1Product Introduction
In order to better protect the safety of sampling personnel and provide a comfortable working environment, our company has designed a movable nucleic acid sampling isolation box, which can provide a safe sampling space for testing personnel.
IIPerformance Characteristics
1) UV antivirus, can be timed.
2) Equipped with primary filtration device and anti-virus high-efficiency air filtration system, the filtration efficiency of 0.3 μ m particles is ≥ 99.995%.
3) Bracket casters, easy to move
4) Positive pressure design of the chamber, with a positive pressure of ≥ 20pa inside the chamber, to prevent external bacteria from flowing into the inner cavity.
5) The internal air supply volume of the warehouse is ≥ 500m3/h
6) Constant temperature control of the chamber, paired with dual air conditioning for both hot and cold.
7) Equipped with a transmission window (UV sterilization, mechanical interlock), the size can be customized.
8) Dual workstation operation, more convenient, fast and user-friendly.

IIITechnical Specifications
Shell size (external)
2100mm*1400mm*2800mm
Shell size (internal)
2000mm*1300mm*2000mm
Shell material
insulation board
Observation window material
Acrylic (organic glass)
Sterilization system
UV lamp sterilization time: 30 minutes to 60 minutes is suitable
air supply system
FLJ power frequency centrifugal blower
filter element
Primary filtration: dustproof sponge pad gaoji filtration: H14 filter
monitor
Internal pressure display (positive pressure 0-30PA), internal temperature display
insulator system
The material of the warehouse body is selected as insulation board
intercom system
Two way window intercom system
lighting system
LED lighting lamp
Split air conditioning system (1 horsepower)
4workflow
1. When sampling, turn on the fan to operate the positive pressure system in the isolation compartment, and adjust the temperature inside the compartment through the air conditioning thermostat;
1. The inspected personnel shall deliver the instrument to the sampling personnel's sleeve according to the instructions;
2. The in cabin sampling personnel use glove operated ports to collect throat swabs from the tested personnel, and after sampling, place the swab swab cotton swab into the sampling tube;
3. The personnel in charge of sample registration and sorting in the cabin shall wipe the surface of the sampling tube passed in by the tested personnel, label and register it, and then put it into the biological sample transfer box;
4. After the sample storage in the biological sample transfer box reaches a certain amount, the personnel in charge of sample registration and sorting inside the container transfer the samples to the personnel in charge of sample transfer outside the container;
5. After the sampling is completed and personnel are evacuated, turn on the ultraviolet lamp and sterilize and disinfect the isolation chamber.
Attention:
1. When using the instrument, try to avoid direct sunlight and avoid using it on rainy days to prevent the normal operation of the instrument from being affected.
2. The normal operating environment temperature of the instrument is -5~30 ℃. If the temperature is too high or too low, it will affect the normal use of the instrument.
After use, please flip the gloves inside the compartment to extend their lifespan.
4. The designed service life of medical gloves in outdoor environments is one month, and the specific time may vary depending on the frequency of glove use and the working environment.
AfterSalesService :
Key words:- Nucleic acid sampling workstation
More Products