Ankerui City Catering Oil Fume Online Monitoring Manufacturer
Ankerui City Catering Oil Fume Online Monitoring Manufacturer

Ankerui City Catering Oil Fume Online Monitoring Manufacturer

Category:

Electrical Engineering/Complete electrical and electrical equipment/Other electrical and electrical equipment

Model:

AcrelCloud-3500

Brand:

Acrel

Retail Price

90,000.00USD


重量

kg

  • Product Description
  • Description :

      Shortcomings in the Treatment of Organic Waste Gas from Kitchen Fumes in the Catering Industry

      Most restaurants do not have pre embedded smoke exhaust systems and safety passages

      Some restaurants located in the old city area have relatively outdated machinery and equipment, and their overall planning and layout are not in accordance with the design scheme. There are many unscientific areas, and the unscientific and reasonable layout leads to an increase in the cost of installing oil fume purifier machinery and equipment. Moreover, the vast majority of restaurants operating in street facing rooms do not have a safe smoke exhaust system, resulting in the immediate discharge of kitchen fumes into the air, which poses a threat to environmental air quality.

      Increase the publicity and planning scope of kitchen smoke exhaust pollution control

      Relying on the energy of various news media, we will make every effort to promote and plan, and raise everyone's awareness of protection. The progress of environmental pollution control and the improvement rate of air quality index in China, in a sense, lies in the development rate of public protection awareness and the enhancement of protection awareness among all staff. Whether it's PM2.5 or kitchen fume control, they are all democratically negotiated.

      Ankerui City Catering Oil Fume Online Monitoring Manufacturer I. Introduction to Catering Oil Fume Monitoring Cloud Platform

      1. Function

      Cooking fumes are one of the main sources of volatile organic compounds (VOCs) and PM10 in the atmosphere. In recent years, with the strengthening of environmental protection governance, various levels have continuously strengthened the full coverage installation of oil fume purifiers by catering operators, but there are still some problems and loopholes in supervision.

      (1) Poor proactive environmental awareness: Most small and medium-sized catering owners believe that holding certificates from the industry and commerce, food and medicine departments is enough to operate legally, ignoring environmental impact assessment approval, resulting in the installation of kitchen fume purification facilities without standardized requirements;

      (2) Due to the direct impact of the power of oil fume purification facilities on the purchase and installation cost and oil fume purification effect, despite the installation of purification equipment, complaints about poor purification effect and oil fume disturbance to residents still occur from time to time;

      (3) Difficulty in self-regulation of businesses: During the inspection process, although catering owners installed oil fume purification equipment, they did not consciously maintain and use it, and the effect of regular cleaning was not significant;

      (4) Difficulty in supervision: There are a huge number of catering enterprises, and it is impossible to achieve full coverage through human supervision. Some monitoring projects require multiple sampling by testing companies and equipment, and require a long time for analysis. The cost and difficulty of supervision are high.

      In order to make up for the loopholes in the existing catering industry's e-liquid monitoring and facilitate the supervision of regulatory authorities, the Ankerui oil fume monitoring cloud platform has emerged. The oil fume monitoring module communicates and exchanges data with the cloud platform through 2G/4G, and the system can monitor the startup and operation status of enterprise catering equipment; Implement functions such as startup rate monitoring, purification efficiency monitoring, facility shutdown alarm, pending cleaning alarm, abnormal alarm, etc; Perform statistical analysis, ranking, and other statistical functions on collected data; Compared to traditional electrostatic monitoring methods, it is safer and more effective.

      2. Application location

      2、 Structure of Catering Oil Fume Monitoring Cloud Platform

      The platform collects data on the operating status of catering fume treatment equipment and the concentration of fume emissions, automatically alerts and warns enterprises with excessive emissions and abnormal situations. Regulatory authorities can quickly handle the situation, urge catering enterprises to rectify their equipment, and regularly clean and maintain them to achieve emission reduction, environmental protection, and non disturbance to the public.

      Install monitoring terminals on site to monitor the working status of the oil fume purifier in real time, including the current of equipment operation. At the same time, compare and analyze the particulate matter concentration at the exhaust outlet. Once the emissions exceed the standard, the system will issue abnormal signals.

      Oil fume monitoring equipment is used to monitor data such as oil fume, particulate matter, NmHc, etc

      Purifier and fan work together to purify oil fumes, while monitoring the current of the purification equipment

      The device uploads the collected data to a remote cloud server via 4G network

      Structure diagram of oil fume monitoring cloud platform

      3、 Hardware parameters of catering fume monitoring cloud platform

      4、 Main functions of the catering fume monitoring cloud platform

      online monitoring

      Monitoring of oil fume emission data, including the collection and monitoring of oil fume emission concentration, particulate matter, NmHc and other numerical values; Simultaneously monitor the start stop status and operational data of the monitoring fan and purifier.

      Alarm data monitoring

      The system generates corresponding emission exceeding alarms based on the collected oil fume values; Analyze the operation data of the purifier and upload the corresponding alarm events such as operation, shutdown, and malfunction of the purification equipment.

      data analysis

      Run time analysis, offline analysis; Alarm proportion and ranking analysis; Historical data statistics, enterprise analysis reports, etc.

      hidden danger management

      The system analyzes the collected alarm data, generates corresponding hazard records, distributes and handles hazards, promptly handles alarms, and forms a closed loop.

      Basic data maintenance

      Personal information, permission maintenance, enterprise information entry, corresponding measurement point information entry, etc.

      data service

      Data collection, SMS reminders, data storage and parsing.

      Equipment cleaning and maintenance

      Develop a maintenance plan for cleaning/replacing the filter element of the oil fume monitoring equipment. After the set deadline is exceeded, the system will generate corresponding alarms to remind users to replace or clean the collection filter element.

      (1) Home Page

      Access to enterprises;

      Display the number of connected enterprises and the number of monitoring points.

      AQI weather;

      Real time AQI weather conditions.

      Alarm rate, exceedance rate, online rate;

      Display the number of alarm companies, alarm rates, including statistics on exceeding standards and online rates.

      (2) Large screen display

      This page displays all basic information of the cloud platform system on a large screen through a warehouse format, mainly including project overview, enterprise hazard ranking, alarm information list, monitoring points and alarm statistics, monitoring point geographic location, work order task statistics, etc.

      (3) Real time monitoring

      The system can filter monitoring points, click on each monitoring point information, and you can see real-time data and 24-hour data change curves. And you can see the historical alarm information of the monitoring nodes.

      Real time monitoring data includes information on the operating current, oil fume concentration, particulate matter concentration, and NMHC concentration of oil fume purifiers and fans.

      (4) Hazard management

      4.1 The backend generates corresponding alarm information during hazard inspections based on the concentration threshold and threshold time set by the measuring point, and provides bell and voice prompts on the homepage

      4.2 Enterprise users confirm hidden dangers, identify the recipients of work orders, work order deadlines, and work order task descriptions

      4.3 The operation and maintenance personnel confirm the content of the work order and handle the hidden dangers, fill in the details of the handling results, upload on-site pictures and other attachments, or conduct secondary distribution

      4.4 Relevant enterprise users can confirm the processing progress of corresponding hazard information on the "Hazard Record" page, including whether it has been processed and distributed.

      (5) Statistical analysis

      5.1 Analysis of Exceeding Standards

      Perform correlation analysis on the collected data of oil fume, particulate matter, and NMHC, display a pie chart of the types and enterprises that exceed the standard, and rank the alarm enterprises. Based on the ranking, analyze and evaluate the data and operational status of relevant enterprises.

      5.2 User Analysis Report

      The user analysis report module summarizes the current alarms of the enterprise and supports exporting templates in Word. The specific template content can be customized according to customer needs.

      5.3 Analysis of Online Duration

      The enterprise online duration report module summarizes the current online and offline duration of monitoring instruments, as well as the online and offline time of fans and purifiers, and displays them in the form of line charts and radar charts.

      (6) Equipment cleaning and maintenance

      Set up a regular cleaning and replacement plan for enterprise detectors, including the installation time of maintenance monitoring points, the previous cleaning time, the next maintenance cycle, corresponding responsible persons, and other information.

      5、 User experience of catering fume monitoring cloud platform

      mobile app

      The APP includes all the above functions, which can be downloaded by scanning the QR code above. After downloading, enter "acroly 123456" in the three columns to experience it.

      WeChat Mini Program

      The mini program includes some of the above functions, which can be accessed by scanning the QR code above. After downloading, enter "acroly 123456" in the three columns to experience it.

      6、 Configuration of Catering Oil Fume Monitoring Cloud Platform

      7、 Business Model of Catering Oil Fume Monitoring Cloud Platform

      (1) Data hosting method

      Ankrui guides users to complete the installation of oil fume monitoring equipment. Users upload data to Ankrui's oil fume monitoring operation cloud platform, entrust Ankrui to manage it, and charge storage fees according to regulations/agreements.

      (2) User built platform

      The platform is built in the user monitoring room (or location), and hardware customers can purchase or apply for Alibaba Cloud servers according to our recommended equipment configuration standards. Ankrui completes the platform construction and training of the operation management team for clients.

      Improve the daily management methods of technical and mechanical equipment for rectification

      Because there are many distributors of fragrant ash oil fume purifiers in the sales market, the quality of their products varies greatly. Therefore, the quality of cleaning equipment can be ensured through product quality certification, strong departmental recommendations, market access systems, annual audits, etc., to prevent counterfeit goods from entering the sales market. The enterprise has implemented the operation process management of the smoke cleaning machine equipment and is responsible for the operation, maintenance, and upkeep of the smoke cleaning machine equipment to ensure its normal and smooth operation, and the smoke cleaning efficiency meets relevant regulations.

      Overall scheme design of the system

      This system software consists of four layers: data information verification, data processing methods and communication, network servers, and human-computer interaction technology.

      The data information verification control module is placed after the exhaust duct cleaning equipment, and is composed of four key components: gas sensors, temperature and temperature sensors, AD conversion control module, and CAN bus control module. The AD control module is used to convert the analog input detected by the gas sensor into a data quantity, and the CAN bus control module is used to transmit the data quantity to the data communication control module placed in the canteen or restaurant.

      According to the data communication control module of the microcontroller, the data information of the oil fume detection connection point received by the CAN bus is solved, and the data information is instantly submitted to the network server by the GRPS control module through the application serial communication push AT command driver. In addition, the positioning function is presented. Kitchen fumes often contain complex components. There are roughly three types: solid particles with sufficient molecular weight and diameter; The second is solid small particles whose quality and diameter result in a force lower than the buoyancy of gas water; The third is gaseous chemical substances, which are mainly harmful substances such as carbon metal oxides caused by the ignition of flammable materials such as coal. Most of them are nitrogen compounds. Long term exposure to these air pollutants such as macrolides can cause DNA air oxidation damage and lipid peroxidation reactions in the body. The original text is based on a comprehensive consideration and decision to apply the composition of volatile compounds in kitchen fumes according to national industry standards to consider the concentration value of kitchen fumes.

      Ankerui City Catering Oil Fume Online Monitoring Manufacturer

    AfterSalesService :

    Key words:
    • Ankerui oil fume online monitoring