Ankerui DTSD1352 Rail Energy Meter
Category:
Electrical Engineering/Complete electrical and electrical equipment/Other electrical and electrical equipment
Model:
DTSD1352-C
Brand:
Acrel
Retail Price
616.00USD
重量
kg
- Product Description
-
Description :
Ankerui DTSD1352 Rail Energy Meter Ankerui has maintained stable growth since its listing in 2012. The company will adhere to the concept of "unity and integrity", insist on stable operation and continuous innovation, and provide more solutions, products, and services for power system users and microgrids.
Rail mounted electric energy meter
Related product recommendation: Three phase integrated current transformer
1 Product Introduction
Function:
This series of products adopts a DIN35mm guide rail installation structure, with a compact size, capable of measuring electrical energy and other electrical parameters, and can set parameters such as clock and rate periods. It has high accuracy, good reliability, and performance indicators that meet the technical requirements of national standards GB/T17215-2002, GB/T17883-1999, and power industry standard DL/T614-2007 for electric energy meters. It also has the function of outputting electric energy pulses; RS485 communication interface can be used to exchange data with the upper computer.
Application scope:
Suitable for sub metering of electricity in government agencies and large public buildings, and can also be used for energy management assessment in enterprises and institutions.
Ordering Example:
Specific model: DDSD1352
Technical requirements: Input voltage single-phase AC220V; Input current 10 (60) A; Direct access; Accuracy level 1.0
Communication protocol: None
Auxiliary power supply: none
2 Technical parameters

3 Product Selection
DDS1352、DDSD1352

DTSD1352

4 External dimensions


technical standard
Accuracy level active 1.0
Reference voltage 220V
Rated frequency 50HZ
Starting current active 0.004Ib (0.1)
Submersible with anti creep logic design
Dimensions 75mm * 83mm * 73mm
Normal operating voltage 0.9Un~1.1Un
Extreme working voltage 0.7Un~1.2Un
Voltage line power consumption ≤ 2W and 5VA
Current line power consumption<1VA
Clock battery voltage 3.6VDC
Clock accuracy (daily error) ≤ 0.5S (23 ℃)
Battery capacity ≥ 1000mAh
Data retention time after power outage ≥ 10 years (using new batteries)
Normal operating temperature -20 ℃~+55 ℃
Extreme working temperature -20 ℃~+70 ℃
Storage and transportation temperature -25 ℃~+70 ℃
Storage and working humidity ≤ 85%
Rate number 4
Number of time periods 5
Display LCD display
Communication baud rate 0~999999.99 kWh
Ankerui DTSD1352 Rail Energy Meter
AfterSalesService :
Key words:- DTSD1352 Rail Energy Meter