Ankerui DTSD series rail energy meter
Category:
Electrical Engineering/Complete electrical and electrical equipment/Other electrical and electrical equipment
Model:
DTSD1352-C
Brand:
Acrel
Retail Price
616.00USD
重量
kg
- Product Description
-
Description :
Ankerui DTSD series rail energy meter Ankerui has maintained stable growth since its listing in 2012. The company will adhere to the concept of "unity and integrity", insist on stable operation and continuous innovation, and provide more solutions, products and services for power system users and microgrids.
Rail mounted electric energy meter
Related product recommendation: Three phase integrated current transformer
1 Product Introduction
Function:
This series of products adopts a DIN35mm guide rail installation structure, with a compact size, capable of measuring electrical energy and other electrical parameters, and can set parameters such as clock and rate periods. It has high accuracy, good reliability, and performance indicators that meet the technical requirements of national standards GB/T17215-2002, GB/T17883-1999, and power industry standard DL/T614-2007 for electric energy meters. It also has the function of outputting electric energy pulses; RS485 communication interface can be used to exchange data with the upper computer.
Application scope:
Suitable for sub metering of electricity in government agencies and large public buildings, and can also be used for energy management assessment in enterprises and institutions.
Ordering Example:
Specific model: DDSD1352
Technical requirements: Input voltage single-phase AC220V; Input current 10 (60) A; Direct access; Accuracy level 1.0
Communication protocol: None
Auxiliary power supply: none
2 Technical parameters

3 Product Selection
DDS1352、DDSD1352

DTSD1352

4 External dimensions


technical standard
Single phase AC input
1) Input frequency: power frequency, 45-65Hz;
2) Voltage range: 220V; suitable for 220V single-phase distribution systems
3) Current range: 5A, 32A, 50A, etc. are optional; Voltage and current are directly connected through terminals
4) Control type current range is 32A, non control type current range defaults to 50A
5) Signal processing: using measurement chips and 24 bit AD sampling;
6) Data update cycle: configurable from 0.05S to 1.00S;
7) Overload capacity: 1.2 times the range is sustainable; Instantaneous (<10 cycles) current 5 times, voltage 1.3 times the range without damage;
8) Input impedance: voltage channel>1 k Ω/V; current channel ≤ 100m Ω;
Ankerui DTSD series rail energy meter
AfterSalesService :
Key words:- DTSD series rail energy meter