Ankerui Catering Oil Fume Online Monitoring System Solution Price
Ankerui Catering Oil Fume Online Monitoring System Solution Price

Ankerui Catering Oil Fume Online Monitoring System Solution Price

Category:

Electrical Engineering/Complete electrical and electrical equipment/Other electrical and electrical equipment

Model:

AcrelCloud-3500

Brand:

Acrel

Retail Price

90,000.00USD


重量

kg

  • Product Description
  • Description :

      The sales market for oil fume purifiers and equipment is not standardized

      During the entire process of kitchen oil fume pollution control, the supervisory agency found that although some restaurants' machinery and equipment contained testing and compliance reports provided by the organization, the model specifications and exhaust air volume on the factory nameplate of the oil fume purifier were mostly inconsistent. Even a large number of factory nameplates for oil fume purifiers have been removed. The catering owner stated that there was no factory nameplate during installation regarding this matter. The reason for such a situation may be that different types of smoke and dust purification machines and equipment that cooperate with each other have the same testing report. All products of the same type are subject to quality inspection reports, resulting in the inability to ensure the quality of smoke and dust purification equipment.

      The TGS2602 model sensor is selected for the inspection of gaseous compounds. This sensor has stable characteristics and many advantages: low functional loss, sensitivity to cooking vapors, low cost, good reliability, and easy use of power circuits. The higher the concentration value of the tested gas, the higher the conductivity of the sensor components. By using the change in conductivity, the corresponding change in gas concentration value can be calculated.

      The total power supply voltage of a part of the power circuit is 9V, and the measurement working voltage of the gas sensor needs to be stable at 2.9V. Therefore, in the design scheme of the article, a constant current source integrated icTL431cdr is applied to reduce the 9V working voltage to a stable 2.9V for the sensor application. When the concentration value of the vapor changes, the resistance value of the measuring resistor also changes accordingly. Because the individual working voltage obtained by the load R7 after the voltage divider circuit is too small to further solve the problem, a voltage follower and operational amplifier are added to increase it by 2 times, and then the working voltage value is transmitted to the microcontroller to solve the problem. In this system, there is a corresponding relationship between the concentration of oil fume gas and the temperature value. The determination of oil fume concentration requires temperature and humidity as references, and the change in temperature and humidity can also be used to observe whether the merchant has used the detection equipment. If the equipment is not enabled, the temperature and humidity values will not change.

      Ankerui Catering Oil Fume Online Monitoring System Solution Price 1. Introduction to Catering Oil Fume Monitoring Cloud Platform

      1. Function

      Cooking fumes are one of the main sources of volatile organic compounds (VOCs) and PM10 in the atmosphere. In recent years, with the strengthening of environmental protection governance, various levels have continuously strengthened the full coverage installation of oil fume purifiers by catering operators, but there are still some problems and loopholes in supervision.

      (1) Poor proactive environmental awareness: Most small and medium-sized catering owners believe that holding certificates from the industry and commerce, food and medicine departments is enough to operate legally, ignoring environmental impact assessment approval, resulting in the installation of kitchen fume purification facilities without standardized requirements;

      (2) Due to the direct impact of the power of oil fume purification facilities on the purchase and installation cost and oil fume purification effect, despite the installation of purification equipment, complaints about poor purification effect and oil fume disturbance to residents still occur from time to time;

      (3) Difficulty in self-regulation of businesses: During the inspection process, although catering owners installed oil fume purification equipment, they did not consciously maintain and use it, and the effect of regular cleaning was not significant;

      (4) Difficulty in supervision: There are a huge number of catering enterprises, and it is impossible to achieve full coverage through human supervision. Some monitoring projects require multiple sampling by testing companies and equipment, and require a long time for analysis. The cost and difficulty of supervision are high.

      In order to make up for the loopholes in the existing catering industry's e-liquid monitoring and facilitate the supervision of regulatory authorities, the Ankerui oil fume monitoring cloud platform has emerged. The oil fume monitoring module communicates and exchanges data with the cloud platform through 2G/4G, and the system can monitor the startup and operation status of enterprise catering equipment; Implement functions such as startup rate monitoring, purification efficiency monitoring, facility shutdown alarm, pending cleaning alarm, abnormal alarm, etc; Perform statistical analysis, ranking, and other statistical functions on collected data; Compared to traditional electrostatic monitoring methods, it is safer and more effective.

      2. Application location

      2、 Structure of Catering Oil Fume Monitoring Cloud Platform

      The platform collects data on the operating status of catering fume treatment equipment and the concentration of fume emissions, automatically alerts and warns enterprises with excessive emissions and abnormal situations. Regulatory authorities can quickly handle the situation, urge catering enterprises to rectify their equipment, and regularly clean and maintain them to achieve emission reduction, environmental protection, and non disturbance to the public.

      Install monitoring terminals on site to monitor the working status of the oil fume purifier in real time, including the current of equipment operation. At the same time, compare and analyze the particulate matter concentration at the exhaust outlet. Once the emissions exceed the standard, the system will issue abnormal signals.

      Oil fume monitoring equipment is used to monitor data such as oil fume, particulate matter, NmHc, etc

      Purifier and fan work together to purify oil fumes, while monitoring the current of the purification equipment

      The device uploads the collected data to a remote cloud server via 4G network

      Structure diagram of oil fume monitoring cloud platform

      3、 Hardware parameters of catering fume monitoring cloud platform

      4、 Main functions of the catering fume monitoring cloud platform

      online monitoring

      Monitoring of oil fume emission data, including the collection and monitoring of oil fume emission concentration, particulate matter, NmHc and other numerical values; Simultaneously monitor the start stop status and operational data of the monitoring fan and purifier.

      Alarm data monitoring

      The system generates corresponding emission exceeding alarms based on the collected oil fume values; Analyze the operation data of the purifier and upload the corresponding alarm events such as operation, shutdown, and malfunction of the purification equipment.

      data analysis

      Run time analysis, offline analysis; Alarm proportion and ranking analysis; Historical data statistics, enterprise analysis reports, etc.

      hidden danger management

      The system analyzes the collected alarm data, generates corresponding hazard records, distributes and handles hazards, promptly handles alarms, and forms a closed loop.

      Basic data maintenance

      Personal information, permission maintenance, enterprise information entry, corresponding measurement point information entry, etc.

      data service

      Data collection, SMS reminders, data storage and parsing.

      Equipment cleaning and maintenance

      Develop a maintenance plan for cleaning/replacing the filter element of the oil fume monitoring equipment. After the set deadline is exceeded, the system will generate corresponding alarms to remind users to replace or clean the collection filter element.

      (1) Home Page

      Access to enterprises;

      Display the number of connected enterprises and the number of monitoring points.

      AQI weather;

      Real time AQI weather conditions.

      Alarm rate, exceedance rate, online rate;

      Display the number of alarm companies, alarm rates, including statistics on exceeding standards and online rates.

      (2) Large screen display

      This page displays all basic information of the cloud platform system on a large screen through a warehouse format, mainly including project overview, enterprise hazard ranking, alarm information list, monitoring points and alarm statistics, monitoring point geographic location, work order task statistics, etc.

      (3) Real time monitoring

      The system can filter monitoring points, click on each monitoring point information, and you can see real-time data and 24-hour data change curves. And you can see the historical alarm information of the monitoring nodes.

      Real time monitoring data includes information on the operating current, oil fume concentration, particulate matter concentration, and NMHC concentration of oil fume purifiers and fans.

      (4) Hazard management

      4.1 The backend generates corresponding alarm information during hazard inspections based on the concentration threshold and threshold time set by the measuring point, and provides bell and voice prompts on the homepage

      4.2 Enterprise users confirm hidden dangers, identify the recipients of work orders, work order deadlines, and work order task descriptions

      4.3 The operation and maintenance personnel confirm the content of the work order and handle the hidden dangers, fill in the details of the handling results, upload on-site pictures and other attachments, or conduct secondary distribution

      4.4 Relevant enterprise users can confirm the processing progress of corresponding hazard information on the "Hazard Record" page, including whether it has been processed and distributed.

      (5) Statistical analysis

      5.1 Analysis of Exceeding Standards

      Perform correlation analysis on the collected data of oil fume, particulate matter, and NMHC, display a pie chart of the types and enterprises that exceed the standard, and rank the alarm enterprises. Based on the ranking, analyze and evaluate the data and operational status of relevant enterprises.

      5.2 User Analysis Report

      The user analysis report module summarizes the current alarms of the enterprise and supports exporting templates in Word. The specific template content can be customized according to customer needs.

      5.3 Analysis of Online Duration

      The enterprise online duration report module summarizes the current online and offline duration of monitoring instruments, as well as the online and offline time of fans and purifiers, and displays them in the form of line charts and radar charts.

      (6) Equipment cleaning and maintenance

      Set up a regular cleaning and replacement plan for enterprise detectors, including the installation time of maintenance monitoring points, the previous cleaning time, the next maintenance cycle, corresponding responsible persons, and other information.

      5、 User experience of catering fume monitoring cloud platform

      mobile app

      The APP includes all the above functions, which can be downloaded by scanning the QR code above. After downloading, enter "acroly 123456" in the three columns to experience it.

      WeChat Mini Program

      The mini program includes some of the above functions, which can be accessed by scanning the QR code above. After downloading, enter "acroly 123456" in the three columns to experience it.

      6、 Configuration of Catering Oil Fume Monitoring Cloud Platform

      7、 Business Model of Catering Oil Fume Monitoring Cloud Platform

      (1) Data hosting method

      Ankrui guides users to complete the installation of oil fume monitoring equipment. Users upload data to Ankrui's oil fume monitoring operation cloud platform, entrust Ankrui to manage it, and charge storage fees according to regulations/agreements.

      (2) User built platform

      The platform is built in the user monitoring room (or location), and hardware customers can purchase or apply for Alibaba Cloud servers according to our recommended equipment configuration standards. Ankrui completes the platform construction and training of the operation management team for clients.

      The promulgation of national industry standards

      In addition to establishing product implementation standards for household oil fume machines, it is proposed to develop consistent sampling and statistical analysis methods for restaurant kitchen oil fume and volatile organic compounds (VOCs), which are pollutants with viscosity, low relative concentration, and non sustained intermittent emissions such as kitchen oil fume, in order to make data monitoring more scientifically researched.

      Wet dust removal and high-pressure electrostatic induction composite oil fume filter

      The technical aspect of the close integration of wet dust removal and electrostatic precipitator is to tightly combine the electrostatic induction oil fume filter and the wet test oil fume filter, filling each other's gaps, removing the shortcomings of the other, and reducing the secondary pollution of the other. The electrostatic induction solution zone can remove large particulate air pollutants from kitchen fumes, making the solved smoke and dust meet international environmental standards. However, it cannot remove small and fine particles and odor molecular structures. Only by charging them can the actual effect of water self spraying be improved. The self spraying solution area flexibly utilizes the positive charge mirror system between free electrons and positive ions and zero potential difference objects to enhance the actual dust removal effect, and carries out relatively clean air pollutants such as smoke and odor; In addition, the use of reactive oxygen species to dissolve water and generate hydrogen peroxide as an oxidant for air oxidation of air pollutants captured by water droplets and fillers reduces the secondary pollution of cooling circulating water, and also reduces the environmental pollution of air caused by reactive oxygen species from electrostatic precipitators.

      One of the key sources of PM2.5 environmental pollution is kitchen fume pollution. According to the detailed information of PM2.5 emissions in China, Shanghai's cleaning, restaurant, and civilian building coatings account for 5% of the total consumption, while Hong Kong's catering industry's PM2.5 emissions account for 1.07% of its total consumption. The key to cooking methods is to use frying and stir frying in areas where kitchen oil fume pollution is significantly higher than in other regions across the country. According to data information, the environmental pollution of PM2.5 in China increased from 10% to 14% from 2012 to 2017. In response to the current serious situation of kitchen oil fume pollution in restaurants, self-supporting kitchen oil fume filters are still the way to solve the problem of oil fume pollution. Single basic principle oil fume purifiers generally have their own disadvantages, such as low cleaning efficiency of centrifugal fans and inability to meet cleaning standards. Overload cleaning is more efficient than centrifugal fans, but it often requires the removal and replacement of filter materials, which is more expensive. Improper treatment of the replaced filter materials can easily cause secondary pollution. The detergent used in the entire wet cleaning process must be carefully collected, otherwise injecting it into the natural environment will cause secondary pollution. The electrostatic induction method increases over time, causing larger oil particles to adhere to the electrical level and reducing corona discharge, which in turn endangers the actual cleaning effect and continues to pose a risk of short circuit faults.

      Ankerui Catering Oil Fume Online Monitoring System Solution Price

    AfterSalesService :

    Key words:
    • Ankerui Oil Fume Online Monitoring System