10 meter pole climbing tool, pole climbing foot buckle, electrician pole climbing tool, foot buckle specification and model
Category:
building materials/Safety protection equipment/Foot buckle
Model:
KLD-10 meters
Brand:
Kelida Electric Appliances
Retail Price
80.00USD
重量
kg
- Product Description
-
Description :
The KLD pole mount buckle produced by Hebei Kelida Electric Appliance Manufacturing Co., Ltd. is available in nine models: 8 meters, 10 meters, 12 meters, 15 meters, 18 meters, 21 meters, 25 meters, 28 meters, and 32 meters.









Precautions for using KLD-10 meter high-altitude foot buckle of KOLIDA brand:
Before installing the pole, check if the pole root is secure. Climbing of newly erected poles is strictly prohibited until the pole foundation is fully secured. In case of erosion, soil erosion, or uplift of electrical poles, soil reinforcement should be carried out first, and the poles should be supported or temporary ropes should be tied before installation. Any electrical pole with loose wires or cables should first check the root of the pole, and install temporary cables or support poles before installing the pole.
Before climbing the pole, check whether the climbing tools, such as foot buckles, pedals, seat belts, ladders, etc., are complete and secure.
When working on electric poles, safety belts and helmets must be worn. The seat belt should be fastened to the pole and sturdy components, and should not be fastened to the cross arm or the top of the pole to prevent the cross arm from being loose, broken, and the seat belt from coming off the top of the pole. After fastening the seat belt, it is necessary to check whether the buckle is securely fastened. When working on the pole, do not lose the safety belt protection. When someone is working on the pole, it is not allowed to adjust or remove the cable.
When using a ladder, someone should support or tie it securely.
When installing the cross arm, it should be checked whether it is firm and in good condition. During inspection, the seat belt should be fastened to the main pole.
On site personnel should wear safety helmets. Personnel on the pole should prevent falling objects, and the tools and materials used should be transmitted with ropes and not thrown around. Pedestrians are strictly prohibited from lingering under the pole.
When encountering heavy fog, thunderstorms, or winds above level 5, it is strictly prohibited to work on electric poles.
AfterSalesService :
Key words:- Electrician pole climbing tool