Quick installation fully insulated scaffolding.10.5-meter construction fully insulated scaffolding.insulated quick installation scaffolding
Quick installation fully insulated scaffolding.10.5-meter construction fully insulated scaffolding.insulated quick installation scaffolding

Quick installation fully insulated scaffolding.10.5-meter construction fully insulated scaffolding.insulated quick installation scaffolding

Category:

building materials/Geosynthetic materials/Scaffolding and its accessories

Model:

KLD-10.5 meters

Brand:

Kelida Electric Appliances

Retail Price

3,200.00USD


重量

kg

  • Product Description
  • Description :

      The Kolida brand insulation quick installation maintenance rack is developed based on on-site requirements using domestic and foreign production technologies; The material is made of light and high-strength glass fiber tube, which has no metal structure as a whole. It has the characteristics of corrosion resistance, aging resistance, easy use, high safety, strong insulation performance, etc. It is mainly suitable for the special use of transformer maintenance operations below 500KV, and is also an ideal alternative to the insulated lift table.

      Compared with general structures, the working conditions of quick installation fully insulated scaffolding have the following characteristics:

      1. The variability of the load is significant;

      2. The fastener connection node belongs to semi-rigid, and the rigidity of the node is related to the quality of the fastener and installation, resulting in significant variation in node performance;

      3. The scaffold structure and components have initial defects, such as initial bending and rusting of the members, significant errors in installation dimensions, and eccentric loading;

      4. The connection point with the wall has a significant variation in the constraint of the scaffolding. The research on the above issues lacks systematic accumulation and statistical data, and does not have the conditions for independent probability analysis. Therefore, the adjustment factor of multiplying the structural resistance by less than 1 is determined through calibration with the safety factor used in the past. Therefore, the design method adopted in this specification is essentially semi probabilistic and semi empirical. The basic condition for design calculation is that the scaffolding meets the structural requirements specified in this specification.

    AfterSalesService :

    Key words:
    • Quick installation fully insulated scaffold