Integrated above ground box pump, roof fire box pump, integrated pump station, fire stabilizing water supply pump station manufacturer
Integrated above ground box pump, roof fire box pump, integrated pump station, fire stabilizing water supply pump station manufacturer

Integrated above ground box pump, roof fire box pump, integrated pump station, fire stabilizing water supply pump station manufacturer

Category:

Security/Firefighting equipment/Fire water supply equipment

Model:

JZFBZ-800-200-60/1

Brand:

Yancheng Jinze

brand:

Yancheng Jinze

model:

JZFBZ-800-200-60/1

type:

Fire water supply

material:

stainless steel

Specifications:

8*2*0.6m

Processing & Customization:

yes

Is it imported:

No

Retail Price

26,000.00USD


重量

kg

  • Product Description
  • brand

    Yancheng Jinze

    model

    JZFBZ-800-200-60/1

    type

    Fire water supply

    material

    stainless steel

    Specifications

    8*2*0.6m

    Processing & Customization

    yes

    Is it imported

    No

    Description :

    on the groundIntegrated Box Pump SystemThe use and characteristics of fire water supply equipment:

      1. The integration of fire box and pump does not affect the municipal water supply network. The complete set of integrated equipment for box and pump is directly connected to the incoming water pipe network. The pressure inside the pipe is fed back to the frequency converter through a pressure sensor, and the frequency converter controls the start stop and frequency conversion of the water pump unit according to the set ideal pressure and safety value. Therefore, the use of non negative pressure frequency conversion water supply equipment will not affect surrounding users.

      2. The integrated fire box pump and water-saving water tank pump complete set of equipment are all sealed structures, completely eliminating the phenomenon of pipeline running, emitting, dripping, and leaking; The equipment does not have a pool or water tank, saving water for cleaning the pool or water tank.

      3. The integrated energy-saving equipment for fire box pumps is connected in series with municipal pipelines, which can fully utilize the pressure of municipal tap water. To improve the water pump, only the differential pressure needs to be supplemented. The equipment has low power and low operating costs.

      4. The integrated complete set of equipment for saving investment in tank pumps can utilize the pressure of the pipeline network, and the selection of water pumps is relatively small, saving equipment investment; No need to set up a pool or water tank, which can reduce corresponding costs; The operation of the equipment does not generate secondary pollution and does not require water treatment investment.

      5. The integrated fire box pump prevents secondary pollution. The complete set of integrated equipment for fire box pump supplies tap water directly to users after being pressurized, and the equipment is completely sealed to prevent impurities from entering and causing pollution.

      6. The integrated installation of fire box pumps is simple and occupies a small area. The complete set of equipment for integrated box pumps does not have a water tank or pool, so it occupies a small area. It is shipped as a complete set and only needs to connect the inlet and outlet pipes during installation, which is convenient, fast, and has a short construction period.

    Integrated ground tank pump Fire stabilizing water supply equipment

      1. The pressure stabilizing pump adopts mechanical seal for sealing, which has the characteristics of reliable sealing and no leakage. Diaphragm tank can be inflated once for long-term use, which can prevent water pollution. The equipment occupies a small area, saves investment, and operates automatically. Fault protection, automatic fault switching.

      2. The equipment is linked with the fire control center, automatically entering the fire protection state in case of a fire alarm, and equipped with a linkage feedback interface. The start of the fire pump can be controlled by direct power frequency start, self coupling voltage reduction start, star delta voltage reduction start, etc., to meet different usage requirements.

      3. Fire control has fault alarm and protection functions such as overvoltage, undervoltage, overcurrent, short circuit, phase loss, and water shortage. The main and backup pumps of fire control have mutual backup functions, and the main pump has mutual backup functions. When the main pump fails, the backup pump will automatically start working.

    AfterSalesService :

    Key words:
    • Integrated ground tank pump