Underground fire pump station anti floating buried box pump integrated manufacturer produces buried booster pump station
Underground fire pump station anti floating buried box pump integrated manufacturer produces buried booster pump station

Underground fire pump station anti floating buried box pump integrated manufacturer produces buried booster pump station

Category:

Environmental Protection/Sewage treatment equipment/Buried sewage treatment equipment

Model:

JZFBZ-700-150-50-1

Brand:

Yancheng Jinze Water Supply Equipment Co., Ltd

model:

JZFBZ-700-150-50-1

purpose:

Fire water supply

Processing & Customization:

yes

Wastewater treatment capacity:

one hundred and sixty

category:

Underground fire pump station

Decontamination rate:

ninety-nine

pump power:

eighteen

Overall dimensions:

700x150x50

Flow meter specifications:

one hundred and sixty

Diameter of water outlet pipe:

four hundred

Inlet pipe diameter:

seven hundred

Specifications:

7X1.5X0.5m

Is it a cross-border source of goods:

No

manufacturer:

Yancheng Jinze

Retail Price

28,000.00USD


重量

kg

  • Product Description
  • model

    JZFBZ-700-150-50-1

    purpose

    Fire water supply

    Processing & Customization

    yes

    Wastewater treatment capacity

    one hundred and sixty

    category

    Underground fire pump station

    Decontamination rate

    ninety-nine

    pump power

    eighteen

    Overall dimensions

    700x150x50

    Flow meter specifications

    one hundred and sixty

    Diameter of water outlet pipe

    four hundred

    Inlet pipe diameter

    seven hundred

    Specifications

    7X1.5X0.5m

    Is it a cross-border source of goods

    No

    manufacturer

    Yancheng Jinze

    Description :

    Underground fire pump stationComposition: 1. The composite BDF module uses hot-dip galvanized steel plates of 3mm and 0.4mm 304/2B food grade stainless steel plates, which are pressed and combined by equipment to achieve a tight fit, thus meeting the requirements of steel plate material strength and stainless steel corrosion resistance.

      2. After compression molding, punching molding is carried out through equipment to meet the assembly requirements of standard modules.

      3. On site assembly and selection of 10 # national standard hot-dip treatment for foundation channel steel, combined with a spacing of 1 meter between each beam, and so on

      4. Assemble according to the atlas and technical requirements, and assemble with Φ 10 * 30 hot-dip galvanized screws and environmental protection, water resistance and anti-aging adhesive strips. After the water tank is assembled and formed, install the tie bars and top columns. The reinforcement is made of hot-dip galvanized steel with a diameter of 48, and is installed horizontally and vertically at a distance of 1 meter. The top pillar is sealed with 4 hot-dip galvanized pipes of diameter 48 evenly distributed per square meter.

      5. According to the installation of the pump room and the screws on the surface of the pump room, inspect and accept them after installation to ensure that they are all sturdy and without any omissions.

      6. Clean up all remaining accessories and garbage in the water tank

      Why does the integrated anti floating buried box pump have no bottom plate

      1. The internal pipeline of the water pump unit is composed of hot-dip galvanized steel pipes, and the inlet of the water pump suction pipe should be located in the suction tank inside the water tank or use a swirl preventer.

      2. Each system pump group should be equipped with manual inspection, automatic low-frequency inspection, flow detection pipelines, and water testing pipelines, in addition to being controlled by a control cabinet for start and stop, to form an intelligent buried box pump integration.

      3. Mechanical ventilation facilities should be installed in the pump room, and the ventilation frequency should not be lower than the requirements of relevant specifications. The ventilation openings at the top of the pump room should be equipped with insect proof nets and rain proof louvers.

      4. For the underground installation of pump units in the BDF anti floating fire integrated pumping station, industrial dehumidification equipment should be installed in the pump room, and the dehumidification equipment model should meet the dehumidification effect inside the pump room. At the same time, the condensed water on the wall inside the pump room can flow into the collection pit through the guide groove set at the bottom of the wall.

    AfterSalesService :

    Key words:
    • Underground fire pump station