Underground fire pump station, integrated buried box pump, non floating pump station, remote intelligent operation
Underground fire pump station, integrated buried box pump, non floating pump station, remote intelligent operation

Underground fire pump station, integrated buried box pump, non floating pump station, remote intelligent operation

Category:

Environmental Protection/Sewage treatment equipment/Buried sewage treatment equipment

Model:

JZFBZ-800-200-60-1

Brand:

Yancheng Jinze Water Supply Equipment Co., Ltd

model:

JZFBZ-800-200-60-1

purpose:

Fire water supply

Processing & Customization:

yes

Wastewater treatment capacity:

two hundred

category:

Underground fire pump station

Decontamination rate:

ninety-nine

pump power:

twenty-two

Overall dimensions:

800x200x60

Flow meter specifications:

two hundred

Diameter of water outlet pipe:

six hundred

Inlet pipe diameter:

eight hundred

Specifications:

8x2x0.6m

Is it a cross-border source of goods:

No

manufacturer:

Yancheng Jinze

Retail Price

32,000.00USD


重量

kg

  • Product Description
  • model

    JZFBZ-800-200-60-1

    purpose

    Fire water supply

    Processing & Customization

    yes

    Wastewater treatment capacity

    two hundred

    category

    Underground fire pump station

    Decontamination rate

    ninety-nine

    pump power

    twenty-two

    Overall dimensions

    800x200x60

    Flow meter specifications

    two hundred

    Diameter of water outlet pipe

    six hundred

    Inlet pipe diameter

    eight hundred

    Specifications

    8x2x0.6m

    Is it a cross-border source of goods

    No

    manufacturer

    Yancheng Jinze

    Description :

    Underground fire pump stationFeatures of the integrated box pump pump station without floating: 1. No need to build a pump room, saving space. 2. Adopting a silent type of fire pump set, it operates without noise and is energy-saving and environmentally friendly. 3. Installing all fire pump sets in the water tank, it has the function of silencing and antifreeze. 4. During equipment maintenance, there is no need to discharge fire water from the water tank, saving energy. 5. It has the functions of water tank shortage alarm, fault alarm automatic switching, and fire linkage

      The fire water tank of the integrated non floating pump station with buried box pump is calculated based on the fire design flow rate and fire duration of each individual fire water supply system in the engineering project to determine the required fire extinguishing water volume for each individual fire water supply system. When a construction project consists of multiple fire water supply systems, the total amount of water used for extinguishing a single fire is the sum of the water used for extinguishing each individual system. From this, the effective volume of the fire water tank is determined, and the size of the fire water tank can be determined based on the tank volume and the actual situation on site.

      Characteristics of the integrated non floating pump station product for buried box pumps: 1. No welding required - all templates, steel structure frames, and accessories are connected by hot-dip galvanized bolts, thus avoiding the disadvantages of difficult anti-corrosion treatment and easy rusting after welding;

      2. Long service life - all load-bearing components are made of hot-dip galvanized and SUS304-2B stainless steel materials, and all are assembled without welding. The sealing material is EPDM (ethylene propylene diene monomer) rubber. The exterior of the pool is coated with epoxy coal tar for corrosion prevention. The interior and exterior of the pool are protected against corrosion with a double-layer coating (asphalt layer+outer hot-dip galvanized layer+inner hot-dip galvanized layer+stainless steel layer). If the galvanized layer is damaged during transportation or installation, epoxy rich zinc+epoxy glass flakes are used for severe corrosion protection, resulting in a long service life;

      3. Short installation cycle - large capacity water tanks are installed in 30-50 days;

      4. No leakage - EPDM (ethylene propylene diene monomer) rubber sealing material is used for the gaps between templates;

      5. Competitive price - comparable to the cost of reinforced concrete water tanks, even saving 30%;

      6. High strength - The product structure design is designed by steel structure engineers from the design institute, and the top pressure and lateral pressure are calculated at 100kN/㎡ and without water; The top pressure and lateral pressure are transmitted to the box body and then to the steel structure skeleton inside the box body;

      7. Energy saving and environmental protection - this product can be reused and regenerated, meeting the current national environmental protection standards and regulations;

      8. Convenient - holes can be opened on site according to the construction unit, and the connecting pipes can be made without welding.

    AfterSalesService :

    Key words:
    • Underground fire pump station