Integrated ground box pump and roof box pump integrated fire stabilizing equipment
Category:
Security/Firefighting equipment/Fire water supply equipment
Model:
JZFBZ-800-200-60/1
Brand:
Yancheng Jinze
brand:
Yancheng Jinze
model:
JZFBZ-800-200-60/1
type:
Fire water supply
material:
stainless steel
Specifications:
8*2*0.6m
Processing & Customization:
yes
Is it imported:
No
Retail Price
26,000.00USD
重量
kg
- Product Description
-
brand Yancheng Jinze
model JZFBZ-800-200-60/1
type Fire water supply
material stainless steel
Specifications 8*2*0.6m
Processing & Customization yes
Is it imported No
Description :
Integrated ground tank pumpProduction of fire stabilizing equipment: (1) Alkali free glass fiber with an alkali metal oxide content of less than 1%, which is equivalent to E-glass fiber. It has excellent chemical stability, electrical insulation, and mechanical properties. (2) The metal oxide content of medium alkali glass fiber is 8% -12%. This type of glass fiber is equivalent to C glass fiber. Due to its high alkali content, its water resistance is poor. The characteristic is chemical resistance, especially acid resistance, which is better than alkali free glass, but the electrical function is poor and the mechanical strength is lower than that of alkali free glass fiber (3). The alkali metal oxide content of high alkali glass fiber is 14% to 15%. This type of glass fiber is equivalent to A glass, and its mechanical strength, chemical stability, and electrical insulation function are all poor. Mainly used for insulation, waterproofing, and moisture resistance, (4) glass fiber is endowed with various special functions due to the addition of special oxides in the formula. Functional products may not necessarily be expensive, but they are definitely suitable. A suitable product is the ultimate goal chosen by users.
Manufacturer of integrated fire pressure stabilizing equipment for roof box pumps
The integrated fire and pressure stabilizing equipment of the box pump does not occupy space. It is strictly prohibited to place debris in the integrated distribution cabinet of the box pump; The use of integrated fire box and pump equipment is becoming increasingly widespread, but in reality, box and pump integration is still quite delicate. If some precautions are not taken during use or installation, it is easy to cause unnecessary damage or failure to the box and pump integration.
For the maintenance of integrated box and pump, first of all, we need to clean the rubber hose and some other components of the integrated box and pump before use. Rust prevention treatment should be carried out for the integrated equipment of fire box pumps. The areas where the anti rust paint has peeled off should be coated with anti rust paint in a timely manner to prevent the integration of the box and pump from getting damp and rusting, which will reduce the service life. In addition, it is necessary to check whether the connections between the various components of the integrated box pump are tight. Ensure that there is no air leakage between the various connections. When the integrated box pump is idle for a long time, a layer of butter should be applied to each metal component of the integrated box pump to prevent rusting. In addition, the connection of the integrated box pump should be unblocked every one to two months. Fire fighting equipment is available without water. Why is this? Especially for older high-rise buildings, 70% have this problem. In earlier years, the power of technology was not enough, and building designs were not as scientific as they are now. Many high-rise buildings did not have adequate water supply systems. When the height of the high-level fire water tank in many high-rise buildings cannot meet the relevant static pressure requirements of the fire protection system, the fire pump cannot supply water. So, what should we do at this time? The integrated boosting and stabilizing equipment for fire box pumps is a fire water supply device used to maintain stable pressure in the working state of the fire water supply system. The integrated boosting and stabilizing equipment for fire box pumps adopts a combination configuration of fire water pumps that meet the requirements, ensuring the performance of the equipment. The integrated boosting and stabilizing equipment of the fire box pump can always maintain the required fire flow and pressure for unfavorable points in the fire water supply system. Once a fire occurs, the fire hydrant or automatic nozzle will release water, the pressure will drop, and an alarm will be triggered to immediately start the fire main pump. It can also be connected to the signal network of the fire button, water flow indicator, and wet alarm valve. Roof box pump integrated fire stabilizing equipment does not occupy space and welding technology. In order to strictly control the quality of products, the special protection inner tank not only selects suitable materials for the Blue Bo insulated water tank inner tank in sales promotion, but also introduces imported computer welding equipment and adopts automatic gas double-sided maintenance low-temperature welding technology to achieve zero damage to the 304 stainless steel anti-corrosion layer, greatly improving the internal service life. The stainless steel of the stainless steel water tank has the ability to resist atmospheric oxidation - that is, rust resistance, and also has the ability to corrode in media containing acid, alkali, and salt - that is, corrosion resistance. However, the size of the corrosion resistance varies with the chemical composition, interaction state, use conditions, and environmental medium type of the steel itself. If a stainless steel water tank has excellent corrosion resistance in a dry and clean atmosphere, but if it is moved to a coastal area in a sea fog containing a large amount of salty components, the stainless steel will rust. All kinds of stainless steel, under any environmental conditions.