Smart heating management system, intelligent heating network, data collection case for steam supply enterprises
Smart heating management system, intelligent heating network, data collection case for steam supply enterprises

Smart heating management system, intelligent heating network, data collection case for steam supply enterprises

Category:

Instrumentation/Flow meter/flowmeter

Model:

STR/WEB/V2.0

Brand:

Qingdao Zhiyuan Instrument

model:

STR/WEB/V2.0

principle:

ultrasonic flowmeter

purpose:

gas flow meter

Nominal Diameter:

DN15-2000

work pressure:

1.6MPa

Applicable Medium:

Gas, liquid, steam

Operating Temperature:

three hundred

measurement range:

six thousand one hundred and eighty-one

accuracy class:

one

measurement accuracy:

one

Installation type:

flange connection

flow range:

two thousand five hundred and fifty

Processing & Customization:

yes

weight:

seventy-seven

Place of Origin:

Qingdao, China

manufacturer:

Qingdao Zhiyuan Instrument

Retail Price

1,766.00USD


重量

kg

  • Product Description
  • model

    STR/WEB/V2.0

    principle

    ultrasonic flowmeter

    purpose

    gas flow meter

    Nominal Diameter

    DN15-2000

    work pressure

    1.6MPa

    Applicable Medium

    Gas, liquid, steam

    Operating Temperature

    three hundred

    measurement range

    six thousand one hundred and eighty-one

    accuracy class

    one

    measurement accuracy

    one

    Installation type

    flange connection

    flow range

    two thousand five hundred and fifty

    Processing & Customization

    yes

    weight

    seventy-seven

    Place of Origin

    Qingdao, China

    manufacturer

    Qingdao Zhiyuan Instrument

    Description :

    Smart heating management system, intelligent heating network, data collection case for steam supply enterprisesThe gradually established thermal user management system includes thermal user data, such as industry classification, gas usage characteristics (intermittent, continuous), and gas usage periods. Through analysis of thermal user data, it guides thermal users to develop reasonable steam usage plans and promotes the day night balance of the total heating load provided by the bidding party; In addition, by understanding the management of heating users and analyzing the possible fluctuations in steam load caused by market and industry influences on heating users in the future, the total steam supply load of the bidding party can be predicted and corresponding steam supply plans can be formulated.

    Smart heating management system, intelligent heating network, data collection case for steam supply enterprisesPartial Function Introduction:

      The data analysis function includes steam analysis of the sum of total table and settlement flow, steam analysis of settlement flow of each sub table and branch line, represented in the form of curves and reports, and can automatically generate pipe losses for each pipeline;

      The system software adopts a networked design, supporting multiple network interfaces and remote browsing. After running the program on the server side, the screen will be published, and various data can be shared by other departments of the thermal power plant through the IE browser. The system has communication function with the power plant MIS system and can transmit the heat network signal to the upper information management system;

      The steam prepaid calculator supports large screen projection function, which can send geographic graphics, data, curves, pipeline diagrams, etc. displayed on the computer to the large screen, making the system have good visibility;

      The design of system software and hardware can facilitate future expansion, upgrading, and transformation; The hardware adopts modular design, which is convenient for transformation and upgrading.

      Equipped with operation logs, it can query the operation process and modify parameters of each customer, achieve traceable and orderly supervision, and avoid operational errors that cannot be traced

    Smart Heating Management SystemActive testing function: It means that at any time, monitoring point data, valve position, flow rate and other data can be actively extracted and uploaded on the server of the dispatch center. The upper computer can set the reporting method arbitrarily. Flexible communication parameter settings: The communication address and baud rate of the prepaid controller can be set as needed (address range: 1-128, baud rates: 2400, 4800, 9600). Currently, the main operating parameters and equipment operations in the factory production process can be collected and managed through the distributed system

      Qingdao Hesheng Zhiyuan Automation System Co., LtdSmart heating management system, intelligent heating network, data collection case for steam supply enterprisesReport function: When the remaining balance is insufficient, the system automatically reports in both directions. The system automatically reports when unpacking. After the power supply is cut off, the system automatically reports in both directions. At the same time, the built-in UPS power supply continues to provide power, and the measurement will not be interrupted after a power outage; Upload valve position, flow rate and other data, and the upper computer can set the reporting method arbitrarily. You can also choose to send it. It has an overdraft function, and the overdraft amount will be deducted immediately during the next recharge (this function has permission restrictions); The system can set the valve opening, automatically control the size of the valve, ensure that the flow rate does not exceed the limit, and perform metering; And upload the actual valve opening in real-time; Simultaneously equipped with a heating function to prevent steam from impacting the pipeline. Lightning protection function: The box machine is equipped with a lightning protection module, but the control box must be reliably grounded. Convenient recharge: When the recharge software writes an IC card, there is no need to manually convert it into gas volume. Simply enter the amount and the software will automatically calculate the gas volume based on the unit. Price management: Different gas prices can be set in the recharge software according to different users, and can be modified at any time.

    Qingdao Hesheng Zhiyuan Intelligent Heating Management SystemPrinciples of Measurement Software Design:

      The system design follows the basic principles of "mature technology, real-time and fast, economical and practical, easy to expand, and easy to upgrade".

      2. The on-site measuring instrument technology meets the standard design, and adopts computer remote mode or assisted management mode.

      3. Adopting a mature fully open, layered, and fully distributed system structure, the system configuration and equipment selection facilitate the expansion of hardware and functionality, and adapt to the rapid development of computer technology. By fully utilizing the technology in the computer field, the system performance can reach the domestic level, ensuring long-term continuous operation of software and hardware, and achieving the goal of "unmanned and few personnel on duty".

      4. The main network topology of the system adopts DDN network to enable communication between each station system and the central workstation, realizing data monitoring and functions. Information publishing is achieved through IE browsing through WEB Server, supporting remote access by intelligent terminals.

      fiveSmart heating management system, intelligent heating network, data collection case for steam supply enterprisesData recovery function: In the event of accidental damage to the control instrument, internal data (mainly user recharge balance) can be recovered, effectively avoiding the occurrence of both parties. Gas and heat recharge, card insertion, query, IC card technology, one card can be easily done, making the charging process from cumbersome manual meter reading and pricing in the past to user card purchase of gas and heat, realizing the automation of gas and heating fee collection and management process. Currently, the main operating parameters and equipment operation in the factory production process can be collected and managed through the distributed system

      Qingdao Hesheng Zhiyuan Automation System Co., Ltd

      189 Hui Xin 5483 Same number 1481

      Q:3438-5007-67

    AfterSalesService :

    Key words:
    • Smart Heating Management System