UK Kane KM950 flue gas analyzer nitrogen oxide detector RTO export nitrogen oxide detector
UK Kane KM950 flue gas analyzer nitrogen oxide detector RTO export nitrogen oxide detector

UK Kane KM950 flue gas analyzer nitrogen oxide detector RTO export nitrogen oxide detector

Category:

Instrumentation/Gas analyzer/flue gas analyzer

Model:

KM950

Brand:

Kane, UK

brand:

Kane, UK

model:

KM950

resolution:

0.1PPM

measurement object:

O2 CO NO NO2 NOX SO2 CO2

measurement range:

0-1000PPM

power supply voltage:

two hundred and twenty

type:

portable

display mode:

digital display

structural style :

handheld

Processing & Customization:

No

gas flow rate:

seven hundred

Specifications:

kane

manufacturer:

Kane, UK

Retail Price

31,000.00USD


重量

kg

  • Product Description
  • brand

    Kane, UK

    model

    KM950

    resolution

    0.1PPM

    measurement object

    O2 CO NO NO2 NOX SO2 CO2

    measurement range

    0-1000PPM

    power supply voltage

    two hundred and twenty

    type

    portable

    display mode

    digital display

    structural style

    handheld

    Processing & Customization

    No

    gas flow rate

    seven hundred

    Specifications

    kane

    manufacturer

    Kane, UK

    Description :

      UK Kane KM950 Smoke Analyzer Nitrogen Oxide Detector RTO Export Nitrogen Oxide Detector Imported Portable Smoke Analyzer

      UK Kane KM950 flue gas analyzer nitrogen oxide detector RTO export nitrogen oxide detector

      RCHB123: I33450I4433 Same V

      Some people say,

      Life is life, work is work,

      I never thought so.

      I have always believed that work and life are inseparable,

      Integrating work into life can make work more humane,

      Life mixed with work can make life more vibrant.

      Where is our original intention and focus,

      Time will be secretly given to you unintentionally

      Don't worry, take your time

      Moved ● ﹏ ●

      I really love learning,

      It's the kind of gaze that yearns for knowledge.

      Enrich oneself, summarize and be good at summarizing

      Make it when there is an order

      When there are no orders, opportunities will be created to find orders

      Gentle yet firm towards life

      Kane, UKKM950flue gas analyzer Introduction:

      Suitable for boiler combustion testing and pollution emission monitoring

      Handheld, fully displayed in Chinese, easy to operate and convenient for on-site use

      Can measure O2, SO2, NO, NO2, CO, flue gas temperature, ambient temperature, flue gas pressure, total efficiency

      Automatically calculate flue gas flow rate CO2、NOx、 Net efficiency, total loss, net loss, excess air coefficient

      Built in dual head powerful vacuum pump ensures normal operation under high negative pressure and fast response time

      Flexible combination of CO, SO2, NO, NO2 sensors, easy to upgrade

      The results show that the conversion between percentage concentration, ppm, and mg/m3 is arbitrary

      Measurement alarm limits for different gas components can be set separately

      The internal special gas path design reduces the loss of SO2 and NOx during testing

      Automatically perform sensor cross interference correction based on smoke status

      Large screen display, backlight function facilitates normal use of the instrument in dim conditions

      Directly display the flow rate of flue gas through pressure measurement

      After booting up, you can directly enter the testing interface without pressing any keys, which is simple and convenient

      Dual use of AC and DC, capable of continuous operation for 6 hours on a full charge

      Data storage function

      Infrared printing method

      Built in automatic calibration program facilitates users to calibrate themselves

      Users can customize the printing content

      

      Kane, UKKM950flue gas analyzer Technical Specifications:

      parameter

      

      resolution

      

      precision

      

      scope

      

      Instructions

      

      flue gas temperature

      

      0.01oC

      

      0.01 ℃± 0.3% reading

      

      0-1200oC

      

      &Use a high-temperature probe at 600 ℃

      

      ambient temperature

      

      0.01oC

      

      0.01 ℃± 0.3% reading

      

      -50℃~50℃

      

      pressure

      

      1pa

      

      ± 2.0% reading

      

      ±15000pa

      

      Over range ± 25000pa

      

      Gas measurement

      

      O2

      

      0.01%

      

      ± 0.2% reading

      

      0-25%

      

      Except for O2 (which is a mandatory test item), users can choose 1-3 sensors from SO2, NO, NO2, and CO according to their needs. The measurement range can also be selected, but it is not possible to select the same sensor for two concentrations at the same time.

      

      CO

      

      1ppm

      

      ± 5% reading

      

      0-10,000ppm

      

      NO (standard range)

      

      1ppm

      

      ± 5% reading

      

      0-5000ppm

      

      NO (low range)

      

      1ppm

      

      ± 5% reading

      

      0-200ppm

      

      NO2

      

      1 ppm

      

      ± 5% reading

      

      0-1000ppm

      

      SO2 (standard range)

      

      1ppm

      

      ± 5% reading

      

      0-5000ppm

      

      SO2 (low range)

      

      1ppm

      

      ± 5% reading

      

      0-200ppm

      

      automatic calculation

      

      CO2

      

      0.1%

      

      ± 0.3% reading

      

      0-99.9%

      

      NOx

      

      1ppm

      

      ± 5% reading

      

      0-6000ppm

      

      loss

      

      0.1%

      

      ± 1.0% reading

      

      0-99.9%

      

      combustion efficiency

      

      0.1%

      

      ± 1.0% reading

      

      0-99.9%

      

      Excess air coefficient

      

      0.1%

      

      ±0.2%

      

      0-2885.0%

      

      Net temperature

      

      0.01oC

      

      0.01 ℃± 0.3% reading

      

      0-1200oC

      

      Smoke velocity

      

      ±0.1m/s

      

      ± 2.2% reading

      

      2-45 m/s

      

      Calculate based on flue pressure and temperature

      

      Built in fuel gauge

      

      Coal, light oil, anthracite, natural gas, coal gas, heavy oil, coke, etc

      

      size

      

      220mm ×55mm ×120mm

      

      weight

      

      1kg

      

      power supply

      

      AC/DC dual-use 220V 50Hz or DC12V

      

      Built in rechargeable battery

      

      6 hours of continuous use after fully charged

      

      Standard Configuration

      

      Host, 350mm long probe, dust and water filter, charger, portable bag, operation manual

      

      option

      

      Infrared printer, 1-meter probe (with built-in PTFE tube)

      

    AfterSalesService :

    Key words:
    • Kane KM950 Smoke Analyzer from the UK