Interscan 4160-2 4160-19.99m imported formaldehyde tester for indoor treatment in the United States
Interscan 4160-2 4160-19.99m imported formaldehyde tester for indoor treatment in the United States

Interscan 4160-2 4160-19.99m imported formaldehyde tester for indoor treatment in the United States

Category:

Instrumentation/Indoor environmental protection testing instruments/Methanol detection instrument

Model:

4160-19.99m

Brand:

Interscan in the United States

model:

4160-19.99m

type:

industrial use

measurement object:

formaldehyde

measurement range:

0.01ppm-19.99ppm

measurement accuracy:

±2.0%

flow range:

zero point eight

power:

twenty-four

resolution:

0.01ppm

power supply:

two hundred and twenty

Processing & Customization:

No

Overall dimensions:

178 x 102 x 225

weight:

two

manufacturer:

Interscan in the United States

Retail Price

25,600.00USD


重量

kg

  • Product Description
  • model

    4160-19.99m

    type

    industrial use

    measurement object

    formaldehyde

    measurement range

    0.01ppm-19.99ppm

    measurement accuracy

    ±2.0%

    flow range

    zero point eight

    power

    twenty-four

    resolution

    0.01ppm

    power supply

    two hundred and twenty

    Processing & Customization

    No

    Overall dimensions

    178 x 102 x 225

    weight

    two

    manufacturer

    Interscan in the United States

    Description :

      Interscan 4160-2 4160-19.99m imported HCHO tester for indoor treatment in the United States

      Interscan 4160-2 from the United States jiaAldehyde detector, also known as 4160-19.99m jiaAldehyde detector

      Today, the editor will briefly introduce several commonly used products on the marketjiaAldehyde detector,

      Interscan 4160-2 from the United StatesTheRIKEN FP-30MK2 (C)ThePPM ppm htv from the UK, ppm ppm st from the UK, and FM-801 from Graves in the US are commonly sold equipment that I have summarized from years of sales experience in the environmental protection industry. Today, the editor will mainly introduce to youInterscan 4160-2 from the United States jiaAldehyde detector. Other styles will be introduced in separate articles. If you like my text content, please contact me~

       RCHB123

      

      1、 4160-2 detector product introduction:

      Produced by INTERSCAN Corporation in the United StatesjiaThe aldehyde gas analyzer is convenient, accurate, and has excellent performance.

      2、 The main applications of the 4160-2 detector are:

      Indoor Civil BuildingsjiaAldehyde content detection, building materialsjiaAldehyde testing and public placesjiaAldehyde detection, etc!

      3、 Performance parameters of 4160-2 detector:

      Accuracy simulation indication: ± 2.0% full-scale digital display: ± 2.0% reading

      Reproducibility: ± 0.5% of full scale

      Minimum inspection line: 1.0% full scale

      range0.01-19.99 ppm 4160-2type Conventional model

       0.01-199.9ppm 4160-1 type

      1ppb-1999 ppb 4160 type

      Zero drift: ± 1.0% full-scale (24 hours)

      Full reading drift: less than ± 2.0% of full scale (24 hours)

      Rise time: less than 1 second

      Size: 178 x 102 x 225 mm

      Weight: 2.0 kg Linearity: ± 1.0% Full Scale

      4、 4160-2 detector instrument configuration list:

      One host

      One portable backpack

      One user manual (in English)

      One user manual (in Chinese)

      One C-12 filter tube

      One piece of connecting hose

      A set of sampling handles

      A plastic syringe

      One charger

      Calibrate one screwdriver

      

       5: 4160-2 Tester Remarks:

      Working Principle:

      The sensor of this instrument is a two electrode sensor, which has a series of advantages that are not present in three electrode sample extraction sensors and diffusion sensors.

      The electrolyte of the sensor is inactive, similar to the electrolyte in flashlights and nickel cadmium batteries. No need to consider battery damage or acid damage to the instrument. The sensor has a sealed air storage chamber, which not only prolongs its lifespan but also eliminates the possibility of reference electrode contamination, eliminating the disadvantage of three electrode sensors requiring air for operation and making it suitable for anaerobic environments. Sample extraction sensors are highly sensitive detectors, with sensitivity 50-200 times greater than diffusion sensors depending on the type of gas. This is a crucial condition for measuring low concentration gases.

      Conversion relationship between mg/m3 and ppm:

      ppm=mg/m3×B/M In the above equation:

      B: The molar volume of gas under standard conditions (at 0 degrees, B=22.4; 250C=24.46 liters)

      M: The molecular weight of the tested substance (HCOH M=30)

      Namely: ppm=mg/m3 × 22.4/30=mg/m3 × 0.74666

      Hygiene standards for public placesjiaThe aldehyde concentration index is 0.12mg/m3. Calculate the relationship between mg/m3 and ppm according to the formula: 0.12mg/m3=0.0896ppm at 0 degrees Celsius and 0.12mg/m3=0.0978ppm at 250C

      Note: 1000ppb=1ppm

      VI4160-2detector Instrument description:

       front panel

      

      Describe the function

      When the measured value exceeds the alarm set point, the ALARM light will flash.

      Alarm setting (SET): Use a screwdriver to adjust the potentiometer and set the alarm point to the desired ppm value (usually not adjusted).

      The sound alarm will sound when the measured value exceeds the alarm point.

      Span Calibration (SPAN) uses a screwdriver to adjust the potentiometer, which can adjust the reading to the corresponding concentration of the calibration gas when calibrating the instrument.(Users are not allowed to adjust on their own)

      Function switch: Rotating this switch has the following functions:

      OFF: Power off

      ZERO: Alarm value setting (used in conjunction with ALARM SET)

      SAMPLE: The pump is turned on. At this location, the instrument can be zeroed, measured, and calibrated

      BAT. TEST A: Turn the switch to this position to display the battery level of the nickel cadmium battery, which supplies power to the pump and bao alarm

      BAT. TEST B: Display the battery level of the 2nd alkaline battery on the screen. This battery pack supplies power to circuits and sensors,Cannot charge

       rear panel

      

      

      air intake

      

      air vent

      

      charge up

      

      Sensor fixing screw

      

      Air outlet(OUT): acceptable1/4Inch gas collection tube (optional)

      Charging socket (3.5mm)): Connected to DC 6V, 400mAcharger

      Seven:4160-2detector instrumentOperation Instructions:

      Check the battery:

      When using the instrument, it is necessary to first check the battery level.

      1) Turn the function switch toBAT.TEST AIf the displayed value is below 1.00, charging is required.

      2) Turn the function switch toBAT.TEST B If the displayed value is below 1.00, the alkaline battery needs to be replaced.

      3) If both of the above levels are above 1.00, you can proceed to the next step.

      

      Instrument zeroing

      1) Turn on the instrument power at the measurement site and turn the function switch toSAMPLEPosition: Remove the plugs from both ends of the C-12 filter, connect the thick end of the connecting hose to one end of the C-12 filter, and insert the thin end forcefully into the air inlet (IN) on the back of the instrument.

      2) The instrument will start zeroing after running stably for about 15 minutes.

      3) After the instrument reading is stable, adjustZEROTurn the knob to display "0.00". After zeroing, remove the C-12 filter and plug both ends with red plugs.

      Attention: When pulling out the air inlet on the back of the instrument from the hose end of the gas collection tube, first press the circular white clip at the air inlet with your hand, and then pull out the hose.

      Note:C-12After multiple uses or in high concentration environments, the filter may become saturated with formaldehyde and its adsorption capacity may decrease, affecting detection accuracy.

      At this point, it is necessary to reactivate the activated carbon in the filter using the following method:

      Pull out the red plugs on both ends of the C-12 filter and place it in a drying oven (oven or microwave cannot be used) set at 40 ℃, and bake for 30 minutes.

      If there is no drying oven, you can also remove the red plug and expose it to sunlight for about 2 hours.

      I suggest replacing a C-12 filter every two years. If the activated carbon in the filter leaks, it must be replaced.

       Start detection

      1) Connect the coiled tube with plastic nut to the white sampling handle, and connect the other end of the coiled tube to the air inlet (IN) on the back of the instrument.

      2) Point the sampling handle towards the measured area and wait for the values to stabilize before reading the measurement results.

      3) When measuring other rooms in a short period of time, if there is little difference in the external environment (temperature, humidity, air pressure, etc.), it can be directly detected without repeating the zeroing process.

      Due to the 4160 modeljiaThe aldehyde analyzer has very high sensitivity and resolution (capable of detecting and resolving one part in a billion)jiaFormaldehyde content, like all precision instruments, requires the elimination of environmental influences during use to ensure the accuracy of instrument detection results.

      Key points to note:

      l According to the national standardGB/TIndoor air quality standard: Close doors and windows before samplingtwelveHours, close doors and windows during sampling; Sampling points should avoid air vents and be located at a distance greater than the wall0.5mRelative height0.5m ~ 1.5mbetween.

      l Due to the indoor environmentjiaThe concentration of aldehydes is very low, so air flow should be avoided as much as possible during sampling (such as personnel walking, air conditioning ventilation, etc.).

      l Do not smoke in the testing environment (released when the cigarette burns)jiaAldehydes).

      four thousand one hundred and sixtyjiaThe sensor of the aldehyde analyzer is sensitive to the gas exhaled by a person, so do not point the sampling handle near the person's mouth and nose during measurement.

      

    AfterSalesService :

    Key words:
    • Imported formaldehyde tester