GD-04Y-3M260 Grounding Module GD-04Y-3M150 Cylindrical Resistance Reduction Module GD-04Y-M200
Category:
Security/Lightning protection equipment/Other lightning protection equipment
Model:
GD-04Y-3M150 GD-04Y-3M260 GD-04Y-M200
Brand:
other
model:
GD-04Y-3M150 GD-04Y-3M260 GD-04Y-M200
type:
Lightning protection grounding material
lifespan:
30 years
Processing & Customization:
yes
Is it imported:
No
Item Number:
GD-04Y-3M150 GD-04Y-3M260 GD-04Y-M200
Specifications:
150*800mm
series:
Lightning protection grounding material
manufacturer:
Qingdao Zhongdian
Retail Price
240.00USD
重量
kg
- Product Description
-
model GD-04Y-3M150 GD-04Y-3M260 GD-04Y-M200
type Lightning protection grounding material
lifespan 30 years
Processing & Customization yes
Is it imported No
Item Number GD-04Y-3M150 GD-04Y-3M260 GD-04Y-M200
Specifications 150*800mm
series Lightning protection grounding material
manufacturer Qingdao Zhongdian
Description :
Construction technology of cylindrical grounding module engineering
The quality of the grounding system is largely determined by the quality of construction, so it is necessary to master the correct construction methods and process quality requirements. The construction of grounding engineering should usually follow the following basic principles:
(1) Within the effective length range, it is recommended to bury grounding bodies in areas with low soil resistivity as much as possible.
(2) The burial location of the grounding body should be away from heat sources.
(3) The burial location of the grounding body should avoid places with strong corrosive substances as much as possible.
(4) The burial location of the grounding body should be as far away as possible from places where people often move, otherwise measures should be taken to prevent step voltage hazards.
(5) According to the actual needs of the project, grounding modules are generally used for horizontal burial or in any other form suitable for terrain conditions.
(6) The burial depth of the grounding body should not be less than 0.8 meters, and it is advisable to bury it appropriately if conditions permit.
(7) The burial spacing of cylindrical vertical grounding bodies should be less than 5 meters. At the bottom of the horizontal grounding ditch, manual excavation or mechanical drilling should be used, with a diameter of not less than 15 centimeters and a depth of 1 meter. Place the grounding module vertically in the hole and weld the upper metal core to the horizontal grounding flat steel.
(8) The same corrosion-resistant metal material must be used to ensure the electrical connection of the buried part of the grounding system is firm and reliable through welding. Overlap welding should be used, and the overlap length should not be less than twice the width of the flat steel or six times the diameter of the round steel, and should be multi sided welding. It is recommended that the length of the weld seam be no less than 100mm. There should be no virtual welding or missed welding.
(9) Careful removal of welding slag is required, and asphalt or other anti-corrosion materials should be applied to the welding area for proper anti-corrosion treatment.
(10) When backfilling with original soil or fine clay, at least 30-50cm of fine soil should be ensured around the grounding body, and appropriate watering should be carried out to fully implement it.

Technical parameter indicators of cylindrical grounding module
model
Appearance (mm)
quality
Power frequency grounding resistance
Room temperature resistivity
Low resistance grounding module
150*800mm
23kg
≤5Ω
≤1.38Ω. m
Calculation of grounding module usage for the specifications in the above table
Based on years of practical experience in using grounding modules to construct grounding grids, the following formula for calculating module usage is summarized:
ρ·M
The calculation result is rounded to an integer when it is a decimal.
Rn·K
In the formula: n is the number of grounding modules.
ρ - Soil resistivity.
M - module grounding coefficient, with a value range of 0.12~0.16. The larger the soil resistivity ρ, the smaller the value of M.
Rn - Grounding resistance value of the grounding network design.
K - Utilization coefficient, with a value range of 0.7~0.85. The more modules there are, the smaller the value of K.
The relationship between the values of various coefficients can be referred to in the following table:
Soil resistivity
Grounding coefficient (M)
Utilization coefficient (K)
ρ<200Ω. m
zero point one six
zero point eight five
200≤ρ<500Ω·m
zero point one five
zero point eight
500≤ρ<1000Ω·m
zero point one three
0.75~0.8
ρ≥1000Ω·m
zero point one two
zero point seven five