Taigu Transformer Manufacturer Dry type Transformer 30kVA Price
Taigu Transformer Manufacturer Dry type Transformer 30kVA Price

Taigu Transformer Manufacturer Dry type Transformer 30kVA Price

Category:

electron/Transformers, inductors/power transformer

Model:

SCB11

Brand:

Changneng

Retail Price

7,000.00USD


重量

kg

  • Product Description
  • Description :

      Transformer manufacturer - Shandong Changneng Transformer Manufacturing Co., Ltd.

      Changneng Transformer Manufacturing Co., Ltd. specializes in the design and manufacturing of over 30 series, including oil immersed transformers, dry-type transformers, amorphous alloy transformers, rectifier transformers, electric furnace transformers, mining transformers, coiled iron core transformers, marine transformers, special transformers, and box type substations, with over 1000 specifications, as well as non-standard products.

      The company adheres to the quality policy of "developing with quality and surviving with reputation", and the business philosophy of "adhering to sincere service and winning the trust of customers from all over the world". It always insists on winning the market with excellent quality and exquisite service

      Shandong Changneng Transformer Manufacturing Co., Ltd. warmly welcomes friends from all walks of life!

      Dry type transformer temperature control system

      The safe operation and service life of dry-type transformers largely depend on the safety and reliability of the transformer winding insulation.

      Cooling method of dry-type transformer

      The cooling methods for dry-type transformers are divided into natural air cooling and forced air cooling. Under natural air cooling conditions, the transformer operates at its rated capacity for a long time. If forced air cooling is used, the output capacity of the transformer will increase by 50%. Suitable for intermittent overload operation or emergency overload operation, the load loss and impedance voltage increase significantly during overload, and it is in a non economic operating state, so it is not desirable to operate continuously for a long time.

      Technical parameters of dry-type transformer

      1. Usage frequency: 50/60Hz;

      2. Empty vibration current:<4%

      3. Voltage resistance: 20000V/min, no damage; Testing instrument: yz1802 voltage tester (20mA);

      4. Insulation grade: F (special grade can be customized);

      5. Insulation resistance: ≥ 2m ohms Test equipment: zc25b-4 megohmmeter<1000V);

      6. Connection methods: Y/Y, △/Y0, よ/△, self connecting (optional accessories);

      7. Allowable temperature rise of coil: i00k;

      8. Heat dissipation method: natural air cooling or temperature controlled automatic heat dissipation.

      9. Noise factor: ≤ 30dB.

      Wiring method of dry-type transformer

      1. Connect the "input" and "output" terminals of the dry-type transformer to a shorter distance, and then test the insulation resistance of the grounding wire using a megameter program. If measured with 1000V megaohms, the resistance is greater than 2m ohms.

      2. The dividing lines of the input and output power lines of dry-type transformers meet the requirements of their current values and are configured with a current density of 2-2.5a/min2.

      3. The input and output three-phase power lines must be connected to phase A, phase B, and phase C according to the busbar color of the transformer end plate. Connect the neutral wire of the voltage transformer of the transformer to the neutral wire, connect the grounding wire, the shell of the dry-type transformer, and the center point of the transformer. The ground wire and neutral wire are generally led out from the neutral point of the transformer. When the transformer has a box, please connect it to the grounding sign on the box.

      Confirm the input and output lines, and verify if they are correct.

      4. First, empty the vibration, then turn on the power and test whether the input and output voltages meet the requirements. Simultaneously observe the machine

      Are there any abnormal noises, sparks, odors, etc. inside? If there is any abnormality, please cut off the input power immediately.

      5. After the air vibration test is completed and normal, the load can be connected.

    AfterSalesService :

    Key words:
    • Taigu Transformer