RB-91D-3/15kw Vortex Cyclone Labeling Machine with Vortex Air Pump and Full Wind Blower Manufacturer Direct Sales
RB-91D-3/15kw Vortex Cyclone Labeling Machine with Vortex Air Pump and Full Wind Blower Manufacturer Direct Sales

RB-91D-3/15kw Vortex Cyclone Labeling Machine with Vortex Air Pump and Full Wind Blower Manufacturer Direct Sales

Category:

Environmental Protection/Fan exhaust equipment/High pressure blower

Model:

RB-91D-3

Brand:

All wind

Retail Price

5,500.00USD


重量

kg

  • Product Description
  • Description :

       RB-91D-3/15kw Vortex Cyclone Labeling Machine with Vortex Air Pump and Full Wind Blower Manufacturer Direct Sales

      Free shipping nationwide: 16 provinces, 4 municipalities directly under the central government, free shipping (Jiangsu, Zhejiang, Shanghai)AnhuiBeijing TianjinHebeiFujianJiangxiShandongChongqingHenanHunanGuangdongHubei Shanxi ShaanxiSichuan Guizhou Yunnan Free shipping (including express delivery), logistics are included in other regions. If you need express delivery, please contact customer service.

       In addition to 6 provinces (Liaoning, Heilongjiang, Jilin, Gansu, Qinghai, Hainan) and 5 autonomous regions: (Guangxi, Inner Mongolia, Xizang Autonomous Region, Xinjiang, Ningxia) and other remote areas are not included in the scope of parcel post. If you need to contact customer service, please add the postage. If you do not contact customer service, we will not ship the goods. Please forgive me, dear!

      Our company has been focusing on the field of fans for more than 10 years, with mature technology, rich experience, and perfect after-sales service! The high-voltage fan adopts advanced German technology, which reduces the noise during operation and improves the noise reduction effect by adding an integrated sound suppression facility. The voltage of the high-voltage fan is universal, 50HZ 60HZ, and can be used. Whether your product is exported to countries in Europe and America that use 60Hz and high voltage, or countries and regions in the Middle East and Africa that use 50Hz voltage, our fans can meet the requirements. If you have special requirements, we can accept non-standard customization!

      

      

      

       This product has passed the European CE certification and CCC certification, and does not require any modifications. After testing, it can be used in Europe, America, Asia, and other regions!

      High pressure fan, high-pressure blower, vacuum vortex air pump specifications:

      Power: 0.18 KW 0.2KW 0.4KW 0.55KW 0.75KW 0.85KW 1.1KW 1.3KW 1.5KW 1.6KW 2.2KW 3.8KW 4KW 5.5KW 7.5KW 8.5KW 9KW

      11KW 12.5KW 13KW 15KW 16.5KW 18.5KW 20KW 25KW 30KW

      High temperature resistant type: 0.4KW 0.75KW 1.5KW 2.2KW 3.7KW 4KW 5.5KW 7.5KW 11KW 15KW 18.5KW

      Single phase voltage: 0.12KW 0.18KW 0.2KW 0.4KW 0.55KW 0.75KW 0.85KW 1.1KW 1.3KW 1.5KW 1.6KW 2.2KW

      Wind pressure: 50mbar-1040mbar (positive pressure: 8KPA-104KPA) (negative pressure: 8KPA-73KPA) (For the convenience of selecting different specifications, single-stage/two-stage models are available in stock)

      Airflow: 40m3/h-3000m3/h (for the convenience of selecting different specifications, both single-stage and two-stage models are available in stock)

      Frequency: 50HZ/60HZ

      Voltage: 110V-200V-220V-280V-380V-400V-415V-440V-600-615V (universal voltage, applicable to all countries). If special voltage is required, it can be customized according to requirements

      Pressure relief valve: RV-01 RV-02 (for use with)

      Filter: MF08 MF10 MF12 MF16 MF20 MF32

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      Faults and solutions

      1、 The fan does not rotate: 1. Not connected to the power supply - connected to the power supply; 2. Motor not working - check motor wiring or replace motor; 3. Damaged fan head - repair or replace the fan; 4. Foreign objects stuck in the fan - remove the foreign objects; 2、 Increased noise: 1. Dry lubrication of bearings - adding bearing grease; 2. Bearing damage - replace the bearing; 3. Impeller wear - replace impeller or pump head; 4. Loose or detached sturdy components - tighten the fasteners tightly; 5. There are foreign objects inside the fan - remove the foreign objects or replace the pump head. 3、 Increased vibration: 1. Bearing damage - replace the bearing; 2. Unbalanced impeller - remove foreign objects from the impeller or calibrate the dynamic and static balance; 3. Main shaft deformation - replace the main shaft or pump head. 4. Entering the turbulent zone in working state - adjusting the working state to avoid the turbulent zone; 5. The inlet and outlet filter screens are blocked - clean the filter screens. 4、 Temperature rise: 1. Excessive intake temperature - reduce intake temperature; 2. Dry lubrication of bearings - adding bearing grease; 3. Reduced fan efficiency - remove blade dust or replace pump head; 4. Change in work status - adjust work status; 5. Environmental temperature increase - increase environmental ventilation fans; 6. Pump body temperature is too high - check if the inlet and outlet are blocked. 5、 Pressure reduction: 1. Pump head speed reduction - low power supply voltage or motor failure; 2. Increase in pipeline resistance - reduce pipeline resistance; 3. Change in work status - adjust work status; 4. Reverse motor direction - rewire the motor. 6、 Flow reduction: 1. Blockage of inlet and outlet air filters - clean the filters; 2. Pump head speed reduction - low power supply voltage or motor failure; 3. Increase in pipeline resistance - reduce pipeline resistance; 4. Increase in work status - adjust work status; 5. Reverse motor direction - rewire the motor.