SVG Reactive Power Compensation: A New Type of Reactive Power Compensation Equipment
SVG Reactive Power Compensation: A New Type of Reactive Power Compensation Equipment

SVG Reactive Power Compensation: A New Type of Reactive Power Compensation Equipment

Category:

Electrical Engineering/Distribution and transmission equipment/Compensation device

Model:

other

Brand:

New Baite/XINBAITE

Retail Price

25,000.00USD


重量

kg

  • Product Description
  • Description :

      SVGreactive power compensator

      I. Overview

      SVG is a typical power electronic device, consisting of three basic functional modules: detection module, control operation module, and compensation output module. Its working principle is based on the current information from the external CT detection system, which is then analyzed by the control chip to obtain the current information, such as PF, S, Q, etc; Then, the controller provides a compensating driving signal, and the inverter circuit composed of power electronic inverter circuit emits a compensating current. The advanced SVG product is STATCOM - Static Synchronous Reactive Power Compensator. The SVG static reactive power generator uses switchable power electronic devices (IGBT) to form a self commutation bridge circuit, which is connected in parallel to the power grid through a reactor. The amplitude and phase of the AC output voltage of the bridge circuit are appropriately adjusted, or its AC current is directly controlled. Quickly absorb or emit the required reactive power to achieve rapid dynamic adjustment of reactive power. As an active compensation device, it can not only track the impulse current of impulse loads, but also track and compensate for harmonic currents.

    svg无功补偿新型的无功补偿设备

      2、 Technical Comparison

      Compared to traditional LC filtering circuits, SVG mainly has the advantages of excellent reactive power compensation performance, support for compensating unbalanced loads, and compensating for zero sequence harmonic currents (mainly 3rd order), which are not available in compensation circuits composed of traditional LC circuits.

      The specific comparison is as follows:

      comparison items

      

      Traditional LC circuit

      

      Sinexcel series SVG

      

      INAS-S series STATCOM

      

      stability

      

      The compensation circuit composed of LC is prone to resonance with the system

      

      Not affected by system harmonics, real-time dynamic compensation, more stable system

      

      No resonance and partial harmonic generation

      

      lifespan

      

      The actual service life usually does not exceed 3 years, with frequent replacement every year or every March, and even tripping when switching on or off

      

      Because there is no issue of resonance overvoltage, it can be used for a long time (MTBF greater than 100000 hours)

      

      The lifespan can reach 15 years

      

      Fast response time

      

      Due to the hierarchical switching, there is no fast response time

      

      Less than 300us, can compensate for rapidly fluctuating loads

      

      Less than 100us

      

      response time

      

      Over 20ms

      

      Less than 5ms

      

      Less than 5ms

      

      Operating range

      

      Generally 0~1, (TCR can reach -1~1), slow switching time

      

      -1~1, calm to emotional adjustment, and can quickly switch

      

      Continuous arbitrary adjustment

      

      Capacity stability

      

      The capacity of capacitors generally decreases every year, and it is recommended to operate for no more than 4 years;

      

      Stable capacity for long-term use

      

      Stable capacity, long-term use

      

      Adjust smoothness

      

      Graded regulation, generally with a switching capacity of 20-60kvar

      

      Stepless adjustment can always ensure stability at the target PF.

      

      Stable power factor above 0.98

      

      harmonic content

      

      larger

      

      Extremely low harmonic content, will not cause secondary pollution to the power grid

      

      No harmonics, and can have some harmonics

      

      stable voltage

      

      Overcharging or undercharging or causing overvoltage or undervoltage of the system voltage

      

      There will be no over or under compensation, which can effectively stabilize the system voltage

      

      There is no phenomenon of over supplementation or under supplementation

      

      Capacity adequacy

      

      When the system voltage is low, it is also a time when the system needs reactive power compensation. However, due to the low system voltage, the compensation capacity of the LC compensation circuit will decrease, making it difficult to provide sufficient compensation capacity.

      

      Due to the use of active compensation circuits, the compensation capacity is basically not affected by the system voltage, and sufficient compensation capacity can be provided under various operating conditions

      

      Can fully achieve the rated compensation capacity

      