61000602 Spring Energy Storage Motor M 220V/250V E1/6 Emax2 Series Air Circuit Breaker Accessories MOTOR OPERATOR 220/250V E1/6
61000602 Spring Energy Storage Motor M 220V/250V E1/6 Emax2 Series Air Circuit Breaker Accessories MOTOR OPERATOR 220/250V E1/6

61000602 Spring Energy Storage Motor M 220V/250V E1/6 Emax2 Series Air Circuit Breaker Accessories MOTOR OPERATOR 220/250V E1/6

Category:

Instrumentation/Electronic Hardware/Other electronic hardware

Model:

D 220/250V E1/6 61000602

Brand:

ABB

brand:

ABB

model:

D 220/250V E1/6 61000602

Item Number:

sixty-one million six hundred and two

Scope of Application:

Framework code E1.2 [1600A] E2.2 [2500A] E4.2 [4000A] E6.2 [6300A]

Overall dimensions:

Release type D [Ekip DIP DIP DIP] T [Ekip Touch] H [Ekip Hi Touch]

weight:

Protection type LI [2-stage protection] LSI [3-stage protection] LSIG [4-stage protection]

Place of Origin:

Shanghai

Retail Price

9,558.47USD


重量

kg

  • Product Description
  • brand

    ABB

    model

    D 220/250V E1/6 61000602

    Item Number

    sixty-one million six hundred and two

    Scope of Application

    Framework code E1.2 [1600A] E2.2 [2500A] E4.2 [4000A] E6.2 [6300A]

    Overall dimensions

    Release type D [Ekip DIP DIP DIP] T [Ekip Touch] H [Ekip Hi Touch]

    weight

    Protection type LI [2-stage protection] LSI [3-stage protection] LSIG [4-stage protection]

    Place of Origin

    Shanghai

    Description :

      ▼ Framework code

      E1.2【1600A】 E2.2【2500A】 E4.2【4000A】 E6.2【6300A】

      ▼ Rated ultimate short-circuit breaking capacity

      B 42kA C 50kA N 66kA

      ▼ Rated continuous current Iu

      630A 800A 1000A 1250A 1600A

      ▼ Type of release device

      D [Ekip DIP DIP DIP] T [Ekip Touch] H [Ekip Hi Touch]

      ▼ Release function

      Basic type

      ▼ Protection type

      LI [2-stage protection] LSI [3-stage protection] LSIG [4-stage protection]

      ▼ Polarity

      3P 4P

      ▼ Installation method

      F fixed type W pull-out type

      ▼ Wiring form

      F front wiring

      ▼ NST standard configuration

      Standard configuration: Circuit breaker body, closing coil (YO) 220V, opening coil (YC) 220V

      Spring energy storage motor (M) 220V, mechanical and electrical indication, and electrical protection for tripping of the release device

      Signal contact S51, auxiliary contact 4CO, external neutral current transformer (only applicable to)

      Circuit breakers with 3 poles and 4 segments of protection; Power supply (only applicable to circuit breakers with H and T release)

      E1B 1600 D LSI WHR 3P NST

    AfterSalesService :

    Key words:
    • Emax2 series air circuit breaker