Mining leakage coaxial cable MSLYFVZ-75-9 coaxial cable
Mining leakage coaxial cable MSLYFVZ-75-9 coaxial cable

Mining leakage coaxial cable MSLYFVZ-75-9 coaxial cable

Category:

communication/Communication cable/Other communication cables

Model:

PTYL23

Brand:

Tianlian

Retail Price

6.00USD


重量

kg

  • Product Description
  • Description :

      Mining Leakage Coaxial Cable MSLYFVZ-75-9 Product Features

      1. The three-dimensional prevention area has clear coverage boundaries and can achieve no blind spots for prevention.

      2. The simple installation method is suitable for complex terrain installation, and can surround any shape of boundary area. The leakage sensing cable part can be buried underground or installed in the wall.

      3. Equipped with anti pet false alarm function, it can filter out the interference of small animals such as puppies and kittens moving in the defense zone

      4. Adaptability is not affected by changes in environmental temperature, humidity, wind, rain, smoke, and tree shaking.

      5. The detailed and broad sensitivity adjustment function has four levels of continuously adjustable sensitivity, and the alarm threshold can be set arbitrarily according to environmental changes.

      MSLYFVZ75-9 Explosion proof Surface Leakage Cable Mining Communication Leakage Cable Leakage Cable Installation

      1. Two cables should not cross or be installed close to each other, and excess cables should be cut off; (including non leakage cables);

      2. Two cables must be laid parallel, with a spacing of 1-3 meters and a spacing of 1.5 meters;

      3. The placement of cables should be determined based on the medium. Generally, the burial depth of mud soil is 10-20 centimeters, and the burial depth of cement soil is 3-7 centimeters;

      4. The plane drop when two cables are laid in parallel shall not be less than 135 degrees;

      5. When installing two sets of cables, it should be ensured that there is an overlapping area of about 3 meters between the tails of adjacent leaking cables, and a gap of about 0.3 meters should be maintained between the two sets of cables in the overlapping area. The operating frequencies of the hosts of two adjacent sets of leaking cables should be staggered;

      6. When the host is installed outdoors, a waterproof protective box should be added to the host;

      7. The power line and signal line cannot be installed in parallel or close to the leakage cable. The distance between the signal line and the leakage cable should be greater than 30 centimeters, and the distance between the 220V power line and the leakage cable should be at least 1 meter;

      8. The standard length of the non leakage cable connecting the host and the leakage cable is 10 meters. The two non leakage cables should be separately protected by conduit, which can be PVC or steel pipe. The distance between two non leaking materials is more than 10 centimeters;

      9. Two leaking cables should be installed in 32MM PVC pipes and buried underground, and should not be inserted into steel pipes;

      10. The burial location of leaked cables should be at least 2 meters away from sidewalks and at least 4 meters away from highways;

      11. If the mining leakage coaxial cable MSLYFVZ-75-9 is buried on one side of the wall, it needs to be 1 meter away from the wall

    AfterSalesService :

    Key words:
    • Mining leakage coaxial cable