RS485 photoelectric smoke fire detector 485 output smoke alarm
RS485 photoelectric smoke fire detector 485 output smoke alarm

RS485 photoelectric smoke fire detector 485 output smoke alarm

Category:

Security/Anti theft and alarm equipment/Other anti-theft and alarm equipment and systems

Model:

JTY-GD-HA621-485

Brand:

Hongsheng High Tech

model:

JTY-GD-HA621-485

Scope of Application:

indoor

power supply:

9-36

contact method:

wired

ambient temperature:

-10+50

Environmental humidity ≤:

ninety-five

alarm method:

On site alarm/signal output

manufacturer:

Hongsheng High Tech

Retail Price

188.00USD


重量

kg

  • Product Description
  • model

    JTY-GD-HA621-485

    Scope of Application

    indoor

    power supply

    9-36

    contact method

    wired

    ambient temperature

    -10+50

    Environmental humidity ≤

    ninety-five

    alarm method

    On site alarm/signal output

    manufacturer

    Hongsheng High Tech

    Description :

      The JTY-GD-HA621-RS485 photoelectric smoke fire detector (hereinafter referred to as the detector) is suitable for fire prediction and alarm in civilian and industrial places such as shopping malls, hotels, shops, warehouses, and motor rooms. The detector has the characteristics of high sensitivity, stability and reliability, low power consumption, beauty and durability, and easy use, and can be used in conjunction with security systems.

      One Performance:

      Alarm sound: ≥ 80dB

      Power supply: DC9V~DC28V

      Current: Static current ≤ 200uA

      Alarm current ≤ 45mA

      Working temperature: -10 ℃~+50 ℃

      Relative humidity: ≤ 95% RH (40 ℃± 2 ℃)

      Smoke sensitivity: 1.06 ±. 26% FT

      Compliant with standard: GB4715-2005

      Communication interface: RS-485

      Communication protocol: Modbus RTU

      II Function:

      Self check: Press the detection button, the detector LED will remain on, and an alarm sound will be emitted (note: self check only checks the internal functions of the detector itself, and there is no relay signal output during self check).

      Work: Under normal circumstances, the detector's indicator light will flash approximately every 6 seconds. The detector automatically detects the smoke concentration in the surrounding environment and compensates for sensitivity based on the usage environment conditions. When the smoke concentration approaches the alarm value, the detector accelerates the intelligent calculation of the smoke concentration trend, and the alarm indicator light starts to flash. If the calculation result reaches or exceeds the alarm value, the detector will start to sound and light an alarm. When the smoke concentration in the surrounding environment drops below the alarm value, the detector automatically resumes normal operation.

      RS-485 communication: Using standard RS-485 communication interface, the communication baud rate can be selected as 2400bps, 4800bps, 9600bps, 19200bps, and the default is 4800bps.

      Modbus RTU protocol: The alarm status register address is 03, which is read using function 03. The status is "0" or "1", normally open ("1" is normal, "0" is alarm), and normally closed ("0" is normal, "1" is alarm).