Anaerobic Box Brand Anaerobic Box Anaerobic Box Manufacturer Supply Laboratory Domestic Anaerobic Box Anaerobic Glove Box
Category:
Instrumentation/Test chamber and climate environment equipment/Incubator
Model:
NB-YYX-8A
Brand:
North South Instruments
model:
NB-YYX-8A
temperature fluctuation:
<±0.3
Temperature Uniformity:
<±1
studio dimensions:
820×660×670
power supply voltage:
two hundred and twenty
power:
six hundred
Overall dimensions:
1260×730×1380
weight:
three hundred and twenty
manufacturer:
North South Instruments
Retail Price
20,706.00USD
重量
kg
- Product Description
-
model NB-YYX-8A
temperature fluctuation <±0.3
Temperature Uniformity <±1
studio dimensions 820×660×670
power supply voltage two hundred and twenty
power six hundred
Overall dimensions 1260×730×1380
weight three hundred and twenty
manufacturer North South Instruments
Description :
Scope of application of NB-YYX-8A anaerobic tank:
The NANPEI North South Anaerobic Chamber is a device that can be used for bacterial cultivation and operation in an anaerobic environment. It provides strict anaerobic conditions, constant temperature cultivation conditions, and a systematic and scientific working area. Inside this device, difficult to grow anaerobic organisms can be cultivated, while avoiding the risk of anaerobic organisms dying due to exposure to oxygen during atmospheric operation. Therefore, this device is an ideal equipment for anaerobic biological detection and research.
Structural characteristics of NB-YYX-8A anaerobic tank:
The NANPEI North South Anaerobic Chamber consists of a constant temperature cultivation room, anaerobic operation room, sampling room, gas and circuit control system, and box rack. This machine has the characteristics of good anaerobic environment, good sealing performance, high temperature control accuracy, good stability, easy use, good economy and reliability
Using scientific methods to achieve high precision and good constant performance in anaerobic environments, a constant temperature anaerobic environment is convenient for operators to operate and cultivate in anaerobic environments.
The temperature control adopts a large LCD screen display and high-precision microcomputer control (with timing), which can accurately and intuitively reflect the actual temperature inside the box. Combined with effective temperature limiting protection, it is safe and reliable.
The box is equipped with ultraviolet sterilization lamps, and the gas enters the box after filtration, which can effectively prevent bacterial contamination.
The pneumatic device adopts a touch sensitive switch to control the solenoid valve, which can accurately adjust the flow rate and input various required gases at will.
The incubator is designed with widened double doors, which changes the phenomenon of touching the front window of the operating room when a single door is opened. The widened doors can accommodate more petri dishes.
The cultivation room and operation room are both made of stainless steel plates, which are smooth, elegant, corrosion-resistant, and durable.
The front window of the operating room is made of thickened transparent impact resistant special glass panels, and the gloves used for operation are reliable, comfortable, flexible, and easy to use.
There is a deoxygenation catalyst installed in the operating room.
Equipped with a leakage protector.
Technical parameters of NB-YYX-8A anaerobic tank:
Product model: NB-YYX-8A
Formation time of anaerobic state in the sampling room:<5 minutes
Anaerobic formation time in the operating room:<1 hour
Anaerobic environment maintenance time:>13 hours in the operating room without replenishing trace amounts of mixed gas
Temperature control range for cultivation room: room temperature+3~60 ℃
Temperature fluctuation in the cultivation room: < ± 0.3 ℃
Temperature uniformity in the cultivation room: < ± 1 ℃
Temperature resolution: 0.1 ℃
Timer function: 1~9999min
Power supply/power: 220V, 50HZ/600W
Net weight/gross weight (kg): 240/320
Indoor dimensions for cultivation: 30 × 19 × 29CM (W × D × H)
Operating room size: 82 × 66 × 67CM (W × D × H)
Dimensions: 126 × 73 × 138CM (W × D × H)
Packaging box size: 139 × 92 × 156CM (W × D × H)
Technical parameters of NB-YYX-8B anaerobic tank:
Product model: NB-YYX-8B
Formation time of anaerobic state in the sampling room:<5 minutes
Anaerobic formation time in the operating room:<1 hour
Anaerobic environment maintenance time:>13 hours in the operating room without replenishing trace amounts of mixed gas
Temperature control range for cultivation room (℃): room temperature+3~60
Temperature fluctuation in the cultivation room (℃): < ± 0.3
Temperature uniformity in the cultivation room (℃): < ± 1
Temperature resolution: 0.1 ℃
Timer function: 1~9999min
Power supply/power: 220V, 50HZ/600W
Net weight/gross weight (kg): 240/320
Indoor dimensions for cultivation: 30 × 19 × 29CM (W × D × H)
Operating room size: 82 × 66 × 67CM (W × D × H)
Dimensions: 126 × 73 × 138CM (W × D × H)
Packaging box size: 139 × 92 × 156CM (W × D × H)
Technical parameters of NB-YYX-8C desktop anaerobic chamber:
Product model: NB-YYX-8C
Formation time of anaerobic state in the sampling room:<5 minutes
Anaerobic formation time in the operating room:<1 hour
Anaerobic environment maintenance time:>13 hours in the operating room without replenishing trace amounts of mixed gas
Temperature control range for cultivation room: room temperature+3~60 ℃
Temperature fluctuation in the cultivation room: < ± 0.3 ℃
Temperature uniformity in the cultivation room: < ± 1 ℃
Temperature resolution: 0.1 ℃
Timer function: 1~9999min
Power supply/power: 220V, 50HZ/1200W
Net weight/gross weight (kg): 240/320
Indoor dimensions for cultivation: 30 × 19 × 29CM (W × D × H)
Operating room size: 82 × 66 × 67CM (W × D × H)
Dimensions: 126 × 73 × 72CM (W × D × H)
Packaging box size: 139 × 92 × 90CM (W × D × H)
Technical parameters of NB-YYX-8D desktop anaerobic chamber:
Product model: NB-YYX-8D
Formation time of anaerobic state in the sampling room:<5 minutes
Anaerobic formation time in the operating room:<1 hour
Anaerobic environment maintenance time:>24 hours in the operating room without replenishing trace amounts of mixed gas
Temperature control range for cultivation room: room temperature+3~60 ℃
Temperature fluctuation in the cultivation room: < ± 0.3 ℃
Temperature uniformity in the cultivation room: < ± 1 ℃
Temperature resolution: 0.1 ℃
Timer function: 1~9999min
Power supply/power: 220V, 50HZ/1200W
Net weight/gross weight: 240/320kg
Indoor dimensions for cultivation: 30 × 19 × 29CM (W × D × H)
Operating room size: 82 × 66 × 67CM (W × D × H)
Dimensions: 126 × 73 × 72CM (W × D × H)
Packaging box size: 39 × 92 × 90CM (W × D × H)
NB-YYX-8E anaerobicboxTechnical Specifications:
Product model: NB-YYX-8E
Temperature control range for incubator use: room temperature+3~60 ℃
Temperature uniformity of incubator: < ± 1 ℃
Temperature fluctuation of incubator: < ± 0.3 ℃
Anaerobic level: Operating room oxygen content<0.1%
Formation time of anaerobic state in the sampling room:<10 minutes
Anaerobic sampling chamber formation method: vacuum+gas displacement (nitrogen+mixed gas)
Formation time of anaerobic state in the operating room:<70 minutes
Anaerobic mode of operation room formation: vacuum+gas replacement (nitrogen+mixed gas)+micro flow mixed gas supplement/control
Maintenance time of anaerobic environment in the operating room: When the supply of trace mixed gases is stopped in the operating room >13 hours
Anaerobic formation control method: Sampling room anaerobic and operation room anaerobic are both one key automatic gas displacement
Size inside the incubator: 42 × 30 × 50cm (W × D × H) can hold 100 90mm petri dishes
Internal volume of incubator: 63L
Sampling room size: 40 × 33 × 32CM (W × D × H)
Sampling room channel size: 27.5 × 29.5CM (W × D × H)
Operating room size: 95 × 68 × 75CM (W × D × H)
Dimensions: 140 × 73 × 137CM (W × D × H)
Packaging box size: 154 × 87 × 155CM (W × D × H)
NB-YYX-8F anaerobicboxTechnical Specifications:
Product model: NB-YYX-8F
Temperature control range for incubator use: room temperature+3~60 ℃
Temperature uniformity of incubator: < ± 3 ℃
Temperature fluctuation of incubator: < ± 0.3 ℃
Anaerobic level: Operating room oxygen content<5ppm
Formation time of anaerobic state in the sampling room:<10 minutes
Anaerobic sampling chamber formation method: vacuum+gas displacement (nitrogen+mixed gas)
Formation time of anaerobic state in the operating room:<70 minutes
Anaerobic mode of operation room formation: vacuum+gas replacement (nitrogen+mixed gas)+micro flow mixed gas supplement/control
Maintenance time of anaerobic environment in the operating room:>13 hours in the operating room without replenishing trace amounts of mixed gas
Anaerobic Formation Control Method: Anaerobic Formation Control Method: Sampling Room Anaerobic and Operating Room Anaerobic are both one key automatic gas displacement
Dimensions inside the incubator: 42 × 30 × 50cm (W × D × H)
Sampling room size: 40 × 33 × 32CM (W × D × H)
Sampling room channel size: 27.5 × 29.5CM (W × D × H)
Operating room size: 95 × 68 × 75CM (W × D × H)
Dimensions: 140 × 73 × 142CM (W × D × H)
Packaging box size: 154 × 87 × 155CM (W × D × H)
Technical parameters of NB-YYX-8G anaerobic tank:
Product model: NB-YYX-8G
Temperature control range for incubator use: room temperature+3~60 ℃
Temperature uniformity of incubator: < ± 1 ℃
Temperature fluctuation of incubator: < ± 0.3 ℃
Anaerobic level: Operating room oxygen content<0.1%
Formation time of anaerobic state in the sampling room:<5 minutes
Anaerobic sampling chamber formation method: vacuum+gas displacement (nitrogen+mixed gas)
Formation time of anaerobic state in the operating room:<70 minutes
Anaerobic mode of operation room formation: vacuum+gas replacement (nitrogen+mixed gas)+micro flow mixed gas supplement/control
Maintenance time of anaerobic environment in the operating room:>13 hours in the operating room without replenishing trace amounts of mixed gas
Anaerobic formation control method: Sampling room anaerobic and operation room anaerobic are both one key automatic gas displacement
CO2 concentration control range: 0-20% Imported infrared sensor CO2 control accuracy ± 0.1%
Humidity control range: 50~90% RH
Humidity fluctuation: ± 3% RH
Power supply/power: 220V, 50HZ/1500W
Shell material: Full 304 stainless steel
Size inside the incubator: 42 × 30 × 50cm (W × D × H) can hold 100 90mm petri dishes
Internal volume of incubator: 63L
Sampling room size: 40 × 33 × 32CM (W × D × H)
Sampling room channel size: 27.5 × 29.5CM (W × D × H)
Operating room size: 95 × 68 × 75CM (W × D × H)
Dimensions: 140 × 73 × 137CM (W × D × H)
Packaging box size: 154 × 87 × 155CM (W × D × H)
Technical parameters of NB-YYX-8H anaerobic tank:
Product model: NB-YYX-8H
Temperature control range for operating room: room temperature+3~60 ℃
Temperature uniformity in the operating room: < ± 1 ℃
Temperature fluctuation in the operating room: < ± 0.3 ℃
Anaerobic level: Operating room oxygen content<0.1%
Formation time of anaerobic state in the sampling room:<5 minutes
Anaerobic sampling chamber formation method: vacuum+gas displacement (nitrogen+mixed gas)
Formation time of anaerobic state in the operating room:<70 minutes
Anaerobic mode is formed in the operating room: vacuum+gas replacement (nitrogen+mixed gas)+micro flow mixed gas supplement and control
Maintenance time of anaerobic environment in the operating room:>13 hours in the operating room without replenishing trace amounts of mixed gas
Anaerobic formation control method: Sampling room anaerobic and operation room anaerobic are both one key automatic gas displacement
CO2 concentration control range: 0-20% Imported infrared sensor CO2 control accuracy ± 0.1%
Humidity control range: 50~90% RH
Power supply/power: 220V, 50HZ/2000W
Shell material: Full 304 stainless steel
Sampling room size: 40 × 33 × 32CM (W × D × H)
Sampling room channel size: 27.5 × 29.5CM (W × D × H)
Operating room size: 190 × 70 × 85CM (W × D × H)
Dimensions: 235 × 81 × 147CM (W × D × H)

AfterSalesService :
Key words:- Anaerobic tank
More Products