V-T3 visible spectrophotometer, photometer manufacturer, laboratory optical instrument, spectrometer
V-T3 visible spectrophotometer, photometer manufacturer, laboratory optical instrument, spectrometer

V-T3 visible spectrophotometer, photometer manufacturer, laboratory optical instrument, spectrometer

Category:

work/optical instrument/Spectrophotometer

Model:

V-T3

Brand:

North South Instruments

model:

V-T3

wavelength range:

320 - 1100nm

Slot size:

four thousand

optical resolution:

±1nm

power supply voltage:

90-250V/AC 50-60HZ

Scope of Application:

- - 0.301 to 3A ; 0-200%T; 0-9999C (0- 9999F)

Processing & Customization:

yes

manufacturer:

North South Instruments

Retail Price

4,147.00USD


重量

kg

  • Product Description
  • model

    V-T3

    wavelength range

    320 - 1100nm

    Slot size

    four thousand

    optical resolution

    ±1nm

    power supply voltage

    90-250V/AC 50-60HZ

    Scope of Application

    - - 0.301 to 3A ; 0-200%T; 0-9999C (0- 9999F)

    Processing & Customization

    yes

    manufacturer

    North South Instruments

    Description :

      V-T3 visible spectrophotometer

      

      V-T3 visible spectrophotometerProduct features

      ● Luminescence measurement: convenient for measuring the absorbance and transmittance of samples at wavelengths.

      Quantitative measurement: Automatically establish standard curves, fit first-order/first-order zero crossing, second-order, and third-order curves, and select multiple measurement and analysis methods. Standard curves can be stored and called;

      Qualitative measurement: Supports continuous recording of up to 100 data points, automatically finding the wavelength position of the large absorption peak

      ● Dynamics measurement: Enzyme kinetics reaction rate calculation

      ● Multi wavelength measurement: Supports data testing for up to 10 wavelength points

      ● Additional functions: automatic wavelength calibration, clock management, light source management, wavelength correction management, language selection

      Standard configuration of V-T3 visible spectrophotometer

      ● 1 host

      One power cord,

      ● One 1CM4 slot manual colorimetric dish rack;

      ● One set of 1cm glass colorimetric dishes (4 pieces)

      ● One user manual for the host

      ● One dust cover

      Product Features

      ● High stability: The optical system and integrated aluminum alloy base structure design ensure the long-term reliability and stability of the instrument

      ● High degree of automation: The hardware design of the dual CPU embedded system is super reliable, with a 126X64 bit LCD display and rich instructions. It does not require reading the manual and is easy to use. The wavelength correction amount and wavelength automatic calibration function can be customized, eliminating the need for manual adjustment. The light source usage time is automatically accumulated for easy viewing. The light source switch menu can be selected to turn off when the instrument is not in use, extending its service life. The Chinese and English languages can be automatically switched between,

      ● Complete menu functions: photometer mode, quantitative analysis, multi wavelength testing;

      ● Convenient data processing: can store up to 1000 sets of data, can be output by built-in and external printers, or can be optionally connected to a computer with Yipu analysis software for data processing and analysis

      Optional attachments: 8-slot automatic sample holder, single slot micro sample holder (small 50UL sample). 5-10 cm sample holder (suitable for water quality analysis). Single or triple bath colorimetric dish holder (suitable for testing samples requiring constant temperature)

      Optional PC side reverse control software will achieve multiple application functions

      Main technical parameters

      model

      

      V-T3

      

      V-T3A

      

      wavelength range

      

      320 - 1100nm

      

      spectral bandwidth

      

      4nm

      

      2nm

      

      optical system

      

      Self aligning optical system, 1200 line/millimeter holographic grating

      

      Wavelength accuracy

      

      ±1nm

      

      wavelength repeatability

      

      ±0.5nm

      

      Luminous range

      

      --0.301 to 3A ; 0-200%T; 0-9999C (0- 9999F)

      

      Transmittance accuracy

      

      ±0.5%

      

      Transmission density repeatability

      

      ±0.2%T

      

      stray light

      

      ≤0.05%T@360nm

      

      drift

      

      ±0.002A/hr @500nm

      

      light source

      

      Tungsten lamp

      

      The data shows

      

      128X64 graphic LCD display

      

      Operating System Language

      

      Automatic switching between Chinese and English

      

      data output

      

      USB interface, Centronics parallel port (optional micro internal and external printers)

      

      Input voltage and frequency

      

      90-250V/AC 50-60HZ

      

      

    AfterSalesService :

    Key words:
    • Visible spectrophotometer