WGZ-3B portable turbidity meter turbidity meter has low voltage indication and automatic shutdown function
WGZ-3B portable turbidity meter turbidity meter has low voltage indication and automatic shutdown function

WGZ-3B portable turbidity meter turbidity meter has low voltage indication and automatic shutdown function

Category:

Instrumentation/Analytical instruments/Turbidity meter

Model:

WGZ-3B

Brand:

North South Instruments

model:

WGZ-3B

Installation method:

portable

display mode:

digital display

type:

Portable turbidity meter

indication error:

±2%

Minimum indication value:

zero point zero one

repetitiveness:

≤1%

zero drift:

±0.5%(0.02 NTU)

power supply voltage:

DC 1.5V × 5 AA alkaline dry batteries AC 220V/50Hz/DC7.5V/0.2A power adapter

Processing & Customization:

yes

Place of Origin:

Zhengzhou

manufacturer:

North South Instruments

Retail Price

4,225.00USD


重量

kg

  • Product Description
  • model

    WGZ-3B

    Installation method

    portable

    display mode

    digital display

    type

    Portable turbidity meter

    indication error

    ±2%

    Minimum indication value

    zero point zero one

    repetitiveness

    ≤1%

    zero drift

    ±0.5%(0.02 NTU)

    power supply voltage

    DC 1.5V × 5 AA alkaline dry batteries AC 220V/50Hz/DC7.5V/0.2A power adapter

    Processing & Customization

    yes

    Place of Origin

    Zhengzhou

    manufacturer

    North South Instruments

    Description :

      WGZ-2AB, 2B, 3B, 4000B portable turbidity meters (instruments) Turbidimeter

      Microcomputer, strong functionality, fully automatic calibration, compatible with printers

      WGZ-3B portable turbidity meterSummary of functions

      Used to measure the scattering degree of light generated by insoluble particulate matter suspended in water or transparent liquids, and to quantitatively characterize the content of these suspended particulate matter. It can be applied to turbidity measurement in power plants, purified water plants, water plants, domestic sewage treatment plants, beverage plants, environmental protection departments, industrial water, liquor and pharmaceutical industries, epidemic prevention departments, and other departments.

      WGZ-3B portable turbidity meterProduct Characteristics

      Portable, powered by AC and DC, with low voltage indication and automatic shutdown function. The serial RS232 communication interface can be paired with a micro printer.

      Low power configuration of microcomputer, touch keyboard, with backlit LCD display screen, capable of displaying date, time, measurement value and measurement unit simultaneously.

      The measurement range can be manually selected or automatically switched. Programmable calibration standard values can be set arbitrarily, and automatic calibration can be selected from 1-7 points.

      It has an average measurement mode and a data query mode, with non-linear processing and smoothing functions for measurement data, and is equipped with self diagnostic information prompts.

      Built in clock memory storage system, real-time storage of measurement and calibration data, capable of long-term storage and retrieval of nearly 20 sets of measurement data.

      Multiple measurement modes are preset, including NTU, FTU, EBC, Unit, ppm, mg/L,%, and other units.

      Equipped with a chromaticity compensation system to avoid interference caused by sample color and accurately reflect the concept of turbidity.

      100000 hours of long-life high-intensity light source, maintenance free for long-term use, in compliance with ISO turbidity measurement standards.

      Technical Specifications

      Model number

      

      WGZ-2AB

      

      WGZ-2B

      

      WGZ-3B

      

      WGZ-4000B

      

      Measurement principle Minimum principle

      

      90 ° scattered light

      

      Minimum read out (NTU)

      

      zero point zero one

      

      zero point zero zero one

      

      zero point zero one

      

      zero point zero zero one

      

      Measuring range (NTU)

      

      0~20

      0~200

      0~500

      

      0~10

      0~100

      0~200

      

      0~10

      0~100

      0~1000

      

      0~10

      0~100

      0~1000

      0~4000

      

      Indication error Basic error (F.S)

      

      ±2%

      

      Repeatability

      

      ≤1%

      

      Zero drift (F.S)

      

      ±0.5%(0.1 NTU)

      

      ±0.5%(0.02 NTU)

      

      Characteristics

      

      Microcomputer configuration, with average measurement mode, display of year, month, day, and time, equipped with data storage and query functions

      Automatic range switching, automatic zeroing, and 1-5 point automatic calibration, equipped with RS232 data communication interface

      Note: Can be paired with an external micro printer

      

    AfterSalesService :

    Key words:
    • Portable turbidity meter