LH-AA9626 Atomic Absorption Spectrophotometer; Single flame 41; spectrophotometer
Category:
work/optical instrument/Spectrophotometer
Model:
LH-AA9626
Brand:
North South Instruments
model:
LH-AA9626
wavelength range:
190-900
optical resolution:
When the wavelength of the manganese double line is less than 40% (spectral bandwidth 0.2nm)
Processing & Customization:
yes
manufacturer:
North South Instruments
Retail Price
104,000.00USD
重量
kg
- Product Description
-
model LH-AA9626
wavelength range 190-900
optical resolution When the wavelength of the manganese double line is less than 40% (spectral bandwidth 0.2nm)
Processing & Customization yes
manufacturer North South Instruments
Description :
LH-AA9626 Atomic Absorption Spectrophotometer (Single Flame)Features
1. Six lamp position light source, automatic switching of lamp positions, searching for element lamp positions;
2. Automatically adjust negative high voltage and constant current, with an average current between 3mA-5mA, to prolong the service life of hollow cathode lamps;
3. Total reflection optical system, eliminating chromatic aberration and improving optical efficiency;
4. Imported components improve instrument performance: imported original photomultiplier tubes, imported original 1800 line gratings;
5. Baseline stability ≤ 0.003A/30min, low noise, high sensitivity, good repeatability, ensuring the operation status of the instrument;
6. The use of Wu's high-efficiency glass atomizer significantly improves the sensitivity, detection limit, and stability of atomic absorption;
7.60 times or more deuterium lamp background correction capability (1Abs);
8. Titanium alloy combustion head, effectively preventing acid gas corrosion;
9. The single flame atomic absorption spectrometer can measure more than 20 elements such as ppm chromium, nickel, lead, zinc, etc. After selecting a graphite furnace, it can detect more than 20 elements such as ppb level silver, aluminum, arsenic, etc
LH-AA9626 Atomic Absorption Spectrophotometer (Single Flame)Technical Specifications
1. Instrument name: Atomic absorption spectrophotometer
2. Product model: LH-AA9626
3. Wavelength range: (190-900) nm
4. Wavelength setting: automatic wavelength scanning
5. Wavelength indication error: automatic calibration
6. Wavelength repetition: 0.15nm
7. Grating engraving: 1800 lines/mm
8. Bandwidth: 0.2nm, 0.4nm, 1nm, 2nm
9. Baseline drift: 0.003A/30min
10. Resolution: When the wavelength of the manganese double line is less than 40% (spectral bandwidth of 0.2nm)
12. Optical system: single beam
13. Background correction: Deuterium lamp/self-priming
14. Read out signals: total absorption, net absorption, background absorption
Flame method parameters
1. Characteristic concentration (Cu): ≤ 0.015 μ g/ml/1%
2. Repeatability (Cu):<0.5%
3. Detection limit (Cu): 0.002 μ g/ml
4. Linear error (Cu): ≤ 10%
Graphite furnace method parameters
1. Temperature range: Room temperature -3000 ℃
2. Light controlled temperature range: (1500-3000) ℃
3. Temperature control accuracy: ≤ 1%
4. Heating rate: ≥ 2000 ℃/S
5. Temperature control period: 20 segments high
6. Cooling water flow rate: 0.46m3/h
7. Characteristic quantity (Cd): 0.3 × 10-12g
8. Repeatability (Cd): ≤ 2%
9. Detection limit (Cd): 0.2 × 10-12g
10. Linear error (Cd): ≤ 15%


AfterSalesService :
Key words:- spectrophotometer