Low concentration and high flow smoke and dust testing instrument RC-3070 microcomputer parallel smoke and dust sampling instrument
Category:
Instrumentation/Gas analyzer/flue gas analyzer
Model:
RC-3070
Brand:
Thermal Holding Environmental Protection
model:
RC-3070
resolution:
1PPM
measurement object:
Smoke and dust
measurement range:
0-5000ppm
power supply voltage:
two hundred and twenty
type:
portable
display mode:
Digital Display
structural style :
number
gas flow rate:
five hundred
Specifications:
portable
manufacturer:
Hot holding
Retail Price
35,000.00USD
重量
kg
- Product Description
-
model RC-3070
resolution 1PPM
measurement object Smoke and dust
measurement range 0-5000ppm
power supply voltage two hundred and twenty
type portable
display mode Digital Display
structural style number
gas flow rate five hundred
Specifications portable
manufacturer Hot holding
Description :
IIILarge flow low concentration smoke and dust tester RC-3070execution standard
JJG 943-2011. Total suspended particulate matter sampler
JJG 956-2013 Verification Regulations for Atmospheric Samplers
HJ/T 374-2007 Technical requirements and detection methods for total suspended particulate matter samplers
HJ/T 375-2007 Technical Requirements and Testing Methods for Environmental Air Samplers
HJ 647-2013 Determination of polycyclic aromatic hydrocarbons in ambient air and exhaust gas phases and particulate matter by high-performance liquid chromatography method
HJ 646-2013 Determination of polycyclic aromatic hydrocarbons in ambient air and exhaust gas phases and particulate matter by gas chromatography-mass spectrometry method
4technical indicators
Main parameters
parameter range
resolution
accuracy
sampling flow
(10~100)L/min
0.01L/min
Better than ± 2.0%
atmospheric pressure
(20~110)kPa
0.01kPa
Not exceeding ± 0.5kPa
Smoke dynamic pressure
(0-2000)Pa
1Pa
Better than ± 2.0%
Smoke static pressure
(-20~20) kPa
0.01kPa
Better than ± 4.0%
Smoke velocity
(0~45)m/s
0.1m/s
Better than ± 4.0%
Front pressure of flowmeter
(-30~0 )kPa
0.01kPa
Better than ± 2.5%
Temperature before flowmeter
(-55~125)°C
0.1°C
Better than ± 1.5%
humidity ratio
(0~60)%
0.1%
Better than ± 1.5%
Smoke temperature
<400℃
O2 (optional)
(0~30)%
0.1%
Better than ± 1.0%
Constant suction velocity
(5~45)m/s
--
Better than ± 5%
Sampling pump load capacity
When the flow rate is 50L/min, the load is ≥ 20 kPa
Sampling volume
99999.9L
0.1L
≤±2.5%
5Instructions for Useone Power-on operation
Press and hold the power button for 2 seconds until the screen lights up, then release it. The detector will turn on and display information such as product name, instrument number, software version number, and power on self-test, as shown in the following figure:
If the self check prompts an error, please contact our after-sales service.

two Main interface operation