XP-329IIIR Japanese New Space Odor Detector
Category:
Instrumentation/Analytical instruments/Gas analyzer
Model:
XP-329IIIR
Brand:
COSMOS
brand:
COSMOS
model:
XP-329IIIR
Item Number:
0132
material:
composite
Installation method:
Portable handheld device
display mode:
Digital Display
Coverage frequency:
one hundred
level accuracy:
two
distortion:
3%
sensitivity:
1%
weight:
one
Specifications:
handheld
Processing & Customization:
No
Whether it is imported:
No
Place of Origin:
Shanghai
Retail Price
30,000.00USD
重量
kg
- Product Description
-
brand COSMOS
model XP-329IIIR
Item Number 0132
material composite
Installation method Portable handheld device
display mode Digital Display
Coverage frequency one hundred
level accuracy two
distortion 3%
sensitivity 1%
weight one
Specifications handheld
Processing & Customization No
Whether it is imported No
Place of Origin Shanghai
Description :
XP-329IIIR Japanese New Space Odor Detector
1: Thank you for reading and understanding the portable odor sensor XP-329 III.
There is a smell all around us. In our daily life, we are surrounded by "smells" such as the smell of food, the odor of factory exhaust gas, and the fragrance of flowers and perfume. Moreover, the 'scent' generally does not stay in one place, but rather drifts away with the flow of air.
It is generally easy for humans to smell (a type of) odor, but in reality, this odor is formed by a mixture of various substances. Odorous substances mix with each other to form different "smells", some further enhance, some cancel each other out, and are almost imperceptible.
The XP-329 III, which is fully functional and easy to use, can capture the constantly changing "odor" at ppb levels (one billionth), and can display subtle changes that are difficult for humans to perceive with digital numbers ranging from "0000" to "20000" and odor indices [equivalent values].

2: Notes on XP-329IIIR Odor Detector!!
This machine is not of explosion-proof construction. Please use in non hazardous areas.
This machine must not inhale the following gases. Otherwise, it will damage the sensor and cause poisoning.
·Strong odor and high concentration gases (especially sulfides), oil mist and other vapors
·Silicone compounds produced by sprays, silicone adhesives, silicone tubes, etc
·Cigarette smoke and other particulate high concentration tar, high concentration fluoride and strong acid substances
·Chlorinated halides, ozone, NOx and other oxidizing gases
3: Explanation of Terminology for XP-329IIIR Odor Detector:
odor
Odors include the "aroma" that represents fragrance and the "odor" that represents foul odor.
Here, "fragrance" and "odor" are collectively referred to as odors.
clean air
Clean air purified using activated carbon filters.
Zero position adjustment (zero position setting)
Before measurement, inhale clean air and set the zero position as the measurement standard.
monitor mode
Continuous and timely display of measurement values in measurement mode.
Normally, the peak value is displayed at the bottom of the measured value.
Batch (BATCH) mode
Display the measurement mode of 1-minute peak value.
Level display
Display the intensity of odor using digital numbers ranging from "0000" to "2000".
The so-called level value refers to the numerical value measured by displaying the level.
Odor Index Display
Convert the data measured by odor sensors using an odor index conversion table to obtain the odor index [equivalent value]. Display with digital numbers ranging from "00" to "40".
The definition of odor index in odor prevention law is "a value obtained by multiplying the dilution factor by 10 when using odorless air to dilute until no odor is felt". Specifically, the three-point comparative odor bag method is used, which is called the panel test subject sniffing three pre prepared bags, selecting one bag containing odor, and slowly diluting it with odorless air until the bag containing odor cannot be smelled. The dilution factor represents the concentration of odor.
The dilution ratio is called odor concentration. Take the logarithm of the odor concentration and multiply it by 10 to obtain the odor index. The conversion formula is,
Odor index=10 × 10g odor concentration.
The INDEX of this device displays the odor index value equivalent to the odor measurement method.
4: Product introduction and parameter display of XP-329IIIR odor detector:
XP-329 Ⅲ R Portable Odor Sensor Features:
The intensity of the odor can be displayed immediately in numbers during detection.
Equipped with digital storage function, the measured values can be retrieved and input into the computer.
The "level" and "odor index (equivalent value)" can be switched.
Notify maintenance time in the form of a bar chart.
XP-329 Ⅲ R Portable Odor Sensor Usage:
Check and confirm the performance of the deodorization device and air purifier.
Measurement of factory exhaust odor and odor from sewage and drainage.
Quality management of various foods and spicy seasonings
XP-329 Ⅲ R portable odor sensor specifications:
Model: XP-329 Ⅲ R
Measurement object: Various aroma and odor components
Measurement principle: High sensitivity indium oxide based hot wire sintered semiconductor
Representation method: LCD digital display (64 × 128 dot matrix) (measured value, usage mode, battery level, data storage number, sensor output horizontal bar, communication channel content, etc.)
Measurement range: When displayed horizontally: 0-2000
When displaying odor index: 0 to (40) [within the equivalent value of 2000 displayed horizontally]
Measurement mode: monitoring/batch processing two modes
Odor Index Conversion Table: * * 3 tables can be inputted (refer to Table 1 when leaving the factory); Coating odor (reference)
Connection terminal: Analog output terminal
When displaying horizontally: relative to 0000-2000 DC0-20mV
When displaying odor index: DC0-200mV with a 5 mV scale relative to 00-40
Digital output input terminal: (RS 232C)
Data storage capacity: Monitoring mode: * * * 8188 data; Batch processing mode: * * 4095 data
Temperature and humidity range: 0-40 ℃ Humidity: 10-80% RH (without condensation)
Size: W84 × H275 × D40mm (excluding protrusions)
Weight: Approximately 640g (including battery)
Power supply: 4 No. 5 alkaline dry batteries, attached dedicated AC adapter (AC100V)
Battery life: Continuous use for more than 8 hours (alkaline dry battery, normal temperature and humidity, Air display attraction status)
※ Battery voltage display and electronic sound function indicate battery life
Standard attachments: Activated carbon filter, emission filter, suction accessories, metal cover for pipes, charging AC adapter, handling box, output cable with connector, communication software package (CD), 4 alkaline dry batteries No. 5, PTFE tube, 2 sets of filter sheets (10 pieces), 2 bags of activated carbon





AfterSalesService :
Key words:- XP-329IIIR
More Products