High strength acid salt index CODMn online automatic monitoring instrument water quality online analyzer
High strength acid salt index CODMn online automatic monitoring instrument water quality online analyzer

High strength acid salt index CODMn online automatic monitoring instrument water quality online analyzer

Category:

Instrumentation/Analytical instruments/Water quality analyzer

Model:

RC-601( xrp)

Brand:

Thermal Holding Environmental Protection

model:

RC-601( xrp)

type:

Rapid water quality analyzer

Installation method:

online

Processing & Customization:

yes

measurement range:

0-20mg/L ; 0-50mg/L ; Customizable range

measurement accuracy:

Detection limit of ≤± 10%: 0.5mg/L

power supply voltage:

two hundred and twenty

resolution:

one

weight:

twenty

Place of Origin:

Qingdao

manufacturer:

Thermal Holding Environmental Protection

Retail Price

25,000.00USD


重量

kg

  • Product Description
  • model

    RC-601( xrp)

    type

    Rapid water quality analyzer

    Installation method

    online

    Processing & Customization

    yes

    measurement range

    0-20mg/L ; 0-50mg/L ; Customizable range

    measurement accuracy

    Detection limit of ≤± 10%: 0.5mg/L

    power supply voltage

    two hundred and twenty

    resolution

    one

    weight

    twenty

    Place of Origin

    Qingdao

    manufacturer

    Thermal Holding Environmental Protection

    Description :

    CODMn online automatic monitoring instrument and water quality online analyzerTechnical Specifications

      The permanganate index is a commonly used indicator to reflect the pollution of organic and inorganic oxidizable substances in water bodies. It is defined as the equivalent amount of oxygen calculated from the consumption of certain organic and inorganic reducing substances in an oxidized water sample under certain conditions. The index cannot be used as an indicator of theoretical oxygen demand or total organic matter content, because under specified conditions, many organic matter can only be partially oxidized, and volatile organic matter is not included in the measured values. The chemical oxygen demand measured using a solution as an oxidant, formerly known as manganese method chemical oxygen demand. In China's new environmental water quality standards, the value has been renamed as permanganate index, and only the value measured by the acidic method is referred to as chemical oxygen demand. The International Organization for Standardization (ISO) recommended method is limited to the determination of surface water, drinking water, and domestic sewage, and is not applicable to industrial wastewater. [3]

      Measurement method: Oxidation titration method

      Measurement range: 0-20mg/L; 0-50mg/L ; Customizable range

      Indication error: ≤± 10% Detection limit: 0.5mg/L

      Repeatability: ≤± 5% Waste liquid volume: 6mL/time

      Memory effect: ≤± 3% Actual water sample comparison: ≤± 10%

      Constant temperature time: 360 seconds Voltage stability: ≤± 5%

      Measurement cycle: 30 minutes Calibration cycle: any time

      Maintenance cycle: ≥ 720h/time Maintenance workload:<2 hours/month

      Reagent consumption: 3 months/500ml Display output: Equipped with a 10.1-inch color LCD touch screen

      Color rendering temperature: The recommended temperature is 160 ℃, which can be set according to the actual water sample situation

      Data export: Measurement values can be imported into a USB drive through a USB port and saved

      Signal output: RS485/RS232/USB interface/standard 2-channel 4-20mA output/standard 2-channel switch input/output

      Environmental requirements: Temperature controlled indoor environment, recommended temperature (5-28 ℃), humidity ≤ 90% (no condensation)

      Power supply and output: (220V ± 22) V/AC, (50 ± 0.5Hz), 5A, 150W

      Instrument size: Upper cabinet 601 * 450 * 301mm; Upper cabinet 701 * 450 * 301mm

      CODMn Online Automatic Monitoring Instrument

      1、 Principle

      Add a known amount of sum to the sample, heat it at high temperature for a certain period of time, and remove the sample

      Some organic and inorganic reducing substances in the product are oxidized, and excess sodium oxalate is added after the reaction to reduce the residue

      Yu, drip excess sodium oxalate back into the standard solution and calculate the sample

      Medium potassium permanganate index value

      2、 Product Features

      The new photoelectric quantitative technology is not affected by interference such as high chromaticity, suspended solids, and bubbles, with high reliability and accuracy, and strong anti-interference ability.

      High detection accuracy, low measurement limit, and small long-term drift of the instrument.

      It has one click self-test function and self diagnostic function.

      Adopting a single channel highly integrated valve group, maintenance and cleaning are simple and fast.

      24/7 networking function, monitoring instrument operation status anytime, anywhere.

      It has alarm function, quality control function, and reverse control function.

      It has automatic cleaning and calibration functions.

      Capable of whole point measurement, interval measurement, and external control measurement.

      Automatically work after power failure and recovery.

      Automatic prompt and reset function for faults and missing reagents (samples).

      L has fault recording function.

      L can save historical data for more than 3 years.

      Ensure separate discharge of cleaning solution and waste liquid

      III

    AfterSalesService :

    Key words:
    • Online water quality analyzer