Solman Si-CA 230 imported flue gas analyzer from France comes with a four-year warranty
Solman Si-CA 230 imported flue gas analyzer from France comes with a four-year warranty

Solman Si-CA 230 imported flue gas analyzer from France comes with a four-year warranty

Category:

Instrumentation/Gas analyzer/flue gas analyzer

Model:

Si-CA 130

Brand:

Thermal Holding Environmental Protection

model:

Si-CA 130

resolution:

one

measurement object:

flue gas

measurement range:

five hundred

power supply voltage:

two hundred and twenty

type:

eleven

display mode:

one

structural style :

one

Processing & Customization:

No

gas flow rate:

one thousand

manufacturer:

Solman

Retail Price

45,000.00USD


重量

kg

  • Product Description
  • model

    Si-CA 130

    resolution

    one

    measurement object

    flue gas

    measurement range

    five hundred

    power supply voltage

    two hundred and twenty

    type

    eleven

    display mode

    one

    structural style

    one

    Processing & Customization

    No

    gas flow rate

    one thousand

    manufacturer

    Solman

    Description :

       Si-CA 230 Product Features

      Designed ergonomically, lightweight and durable

      Automatically record data; generate report

      Pre reminder maintenance, sensor lifespan& Calibration cycle prompt

      One click on/off air pump

      Computer software that can be connected wirelessly; USB connection

      High concentration CO automatic dilution protection (adjustable)

      Graphic display

      Personalized settings analysis display parameters

      Choose and pair with pitot tube to measure flue gas velocity

      Extraction/differential pressure measurement

      Can set O2 reference base

      Anti slip rubber protective cover for the host

      4-year warranty service

      Chinese operating interface

      Si-CA 230 Set contents

      Dimensions

      Si-CA 230 Technical Specifications

      parameter

      

      sensor

      

      range

      

      resolution

      

      degree(1)

      

      Tninety response time

      

      O2

      

      electrochemistry

      

      0 ~ 25%

      

      0.01 %

      

      ± 0.2% vol

      

      < 30 s

      

      CO

      

      electrochemistry

      

      0 ~ 8,000 ppm

      

      1 ppm

      

      ± 8 ppm ( 0 ~ 159 ppm)

      ± 5% measurement value (160~2000 ppm)

      ± 10% measurement value (2001~8000 ppm)

      

      < 40 s

      

      CO

      (H2 compensation)

      

      electrochemistry

      

      0 ~ 10,000 ppm

      

      1 ppm

      

      ± 8 ppm ( 0 ~ 159 ppm)

      ± 5% measurement value (160~2000 ppm)

      ± 10% measurement value (2001~8000 ppm)

      

      < 40 s

      

      

      (1) The degrees referred to in the document are experimental values at 20 ° C and 1013 mbar, which can ensure the accuracy of the measured values under the same conditions.

      (2) Only for measuring the degree of the instrument.

      (3) High calorific value/(4) low calorific value

      Si-CA 230 Host specifications

    AfterSalesService :

    Key words:
    • Imported flue gas analyzer