MSA PrimaXP Fixed Ammonia Gas Detector from the United States
Category:
Instrumentation/Indoor environmental protection testing instruments/Ammonia gas detector
Model:
primaxp
Brand:
MSA/Mesian
brand:
MSA/Mesian
model:
primaxp
type:
fixed type
measurement range:
50ppm
measurement object:
NH3
measurement accuracy:
0.1PPM
resolution:
one
power supply:
24V
Processing & Customization:
yes
Scope of Application:
one
Overall dimensions:
twelve
manufacturer:
msa
Retail Price
11,500.00USD
重量
kg
- Product Description
-
brand MSA/Mesian
model primaxp
type fixed type
measurement range 50ppm
measurement object NH3
measurement accuracy 0.1PPM
resolution one
power supply 24V
Processing & Customization yes
Scope of Application one
Overall dimensions twelve
manufacturer msa
Description :
Prima XP fixed gas detector from the United States1、 Product Features1. Detect oxygen, combustible gases, and various toxic gases; 2. Multi functional large LCD screen with built-in operation keyboard; 3. Plug in sensors are easy to maintain and provide a reminder function for sensor replacement; 4. Modular design, 4-20mA output, optional HART and relay; 5. Integrate and quickly install backboards; 6. Complete product certification, SIL2、CCCF、ATEX、IECEx、UL、CSA2、 Product parameters Physical characteristics 1. Shell material: coated aluminum alloy shell 2. Size: (220 x 162 x 100) mm 3. Weight: 1.6 kg 4. Shell inlet: 2 x M25 or 2 x 3/4 "NPT inlet Environmental characteristics 1. Temperature: -40 ° C to+70 ° C 2. Humidity: 15% to 90% RH Non condensing 3. Protection level: IP66 Detection performance 1. Gas category: combustible gas, oxygen and toxic gas 2. Sensor: Gas type Range: 0-100% LEL Oxygen 0-25% Vol. (CO) 100, 200, 500, 1000 ppm (H2S) 10, 20, 50, 100 ppm Sulfur dioxide (SO2) 10, 20, 50, 100 ppm (Cl2) 5, 10 ppm ammonia (NH3) 50, 100, 500, 1000 ppm nitrogen dioxide (NO2) 10, 20, 100 ppm (HCN) 10, 20, 30, 50 ppm (HCl) 10, 20, 30 ppm (HF) 5, 10 ppm nitric oxide (NO) 100 ppm hydrogen (H2) 1000 ppm phosphine (PH3) 1 ppm Silane (SiH4) 20,50 ppm hydrogen bromide (HBr) 30 ppm germane (GeH4) 2 ppm fluorine gas (F2) 1 ppm (B2H6) 1 ppm bromine gas (Br2) 10 ppm (AsH4) 1 ppm transmitter working requirements 1. Catalytic combustion gas sensor anti poisoning catalytic combustion sensor. 2. Can withstand over range combustible gas (0-100% LEL) 3. Operating voltage: 19.2 to 28.0 VDC, usually 24 VDC 4. Output signal: 4-20mA output with optional HART, can load 300 ohms 5. Wiring method: standard 3-wire output or 4-wire isolated current type 6. Sensor: sensor does not require periodic addition of reaction medium 7. Relay: optional two sets of relays - alarm and fault (1A/30VDC SPST)3、 Installation and accessories 1. Backboard: The shell comes with a back board that can be easily installed on walls or similar objects. 2. Pipeline installation: optional pipeline installation accessories are provided. 3. Sensor protective cover: The sensor comes with a standard protective cover to prevent external environmental interference. 4. Conduit installation flange: A conduit installation flange can be provided to detect conduit gases. 5. Sunshade: A sunshade is provided to protect against direct sunlight and high temperatures. 6. Setting/Calibration: All instrument settings and calibration operations can be achieved through the built-in four key keyboard or optional HART controller. 7. L E D indicator light: built-in 3 status LED indicator lights 8, red L E D: alarm status 9, yellow L E D: fault status 10, green L E D: normal working status 11, display: 4.5-inch high brightness LCD screen, on-site display of monitored gas type and current detection reading4、 Product certification 1. Hazardous Area Certification CE ATEX 2、Gas – II 2G Ex d ia (ia) IIC T4 Ga 3、Dust – II 2D Ex tb ia (ia) IIIC T130 ° C Db 4, -40 ° C ≤ Ta ≤+70 ° C 5, UL Class I, Div 1, Group A, B, C, D 6, CMC, EX, CCCF 7, Safety Integrity Level SIL 2
AfterSalesService :
Key words:- Ammonia gas detector