Thermal Holding Environmental Protection RC-60E Smoke and Dust Automatic Tester
Thermal Holding Environmental Protection RC-60E Smoke and Dust Automatic Tester

Thermal Holding Environmental Protection RC-60E Smoke and Dust Automatic Tester

Category:

Instrumentation/Gas analyzer/flue gas analyzer

Model:

RC-60E

Brand:

Thermal Holding Environmental Protection

model:

RC-60E

resolution:

1PPM

measurement object:

flue gas

measurement range:

5000ppm

power supply voltage:

two hundred and twenty

type:

portable

display mode:

electron

structural style :

handheld

Processing & Customization:

yes

gas flow rate:

five hundred

Specifications:

handheld

manufacturer:

Thermal Holding Environmental Protection

Retail Price

29,800.00USD


重量

kg

  • Product Description
  • model

    RC-60E

    resolution

    1PPM

    measurement object

    flue gas

    measurement range

    5000ppm

    power supply voltage

    two hundred and twenty

    type

    portable

    display mode

    electron

    structural style

    handheld

    Processing & Customization

    yes

    gas flow rate

    five hundred

    Specifications

    handheld

    manufacturer

    Thermal Holding Environmental Protection

    Description :

      The execution standard for the RC-60E automatic smoke and dust testing instrument for thermal holding environmental protection is:

      JJG968-2002 Smoke Analyzer

      HJ/T48-1999 Technical Conditions for Smoke and Dust Samplers

      JJG680-2007 Smoke and Dust Tester

      Enterprise standard: Q/0213LBJ 002-2016

      Product Features:

      1. Can measure parameters such as smoke, moisture content, flow rate, dynamic pressure, static pressure, smoke temperature, oil fume, and smoke (such as O2, SO2, NO, NO2, CO, CO2, H2S)

      2. Equipped with ZD-24 DC power box, it can be used for both AC and DC

      3. Equipped with a flue gas preprocessor for dust filtration, heating, and dehydration treatment, the data is more accurate

      4. One million sets of data storage, RS232 connected to printer, USB memory makes data easier to analyze

      5. One click sampling function

      6. The drying cylinder is equipped with drying and filtering functions, enabling long-term monitoring

      7. Chinese intelligent point and shoot machine operation interface, digital LED screen rotates 360 ° left and right for more convenient operation

      8. Internal structural design such as power-off protection and password protection

      9. Real time reading of parameters such as dynamic pressure, static pressure, ambient temperature, smoke temperature, rotational speed, flow rate, flow rate, moisture content, etc

      10. Sampling system, imported electrochemistry, and modular design ensure the accuracy of testing

      11. Equipped with a multifunctional sampling tube bracket for high-altitude hole sampling

      Thermal Holding Environmental Protection RC-60E Smoke and Dust Automatic Tester Product Parameters:

      

      parameter range

      

      resolution

      

      error

      

      

      sampling flow

      

      5~ 80 L/min

      

      0.1 L/min

      

      ≤±2.5%

      

      

      Flow control stability

      

      ≪ ± 2% (voltage varies between 180V and 250V, resistance varies within 3-6 kPa)

      

      

      Smoke dynamic pressure

      

      0~2000 Pa

      

      1 Pa

      

      ≤±1.5%

      

      

      Smoke static pressure

      

      -30.00 ~+30.00 kPa

      

      0.01 kPa

      

      ≤±2 %

      

      

      Front pressure of flowmeter

      

      -40.00 ~0 .00kPa

      

      0.01 kPa

      

      ≤±2 %

      

      

      Temperature before flowmeter

      

      -30.0 ~ 150.0℃

      

      0.1℃

      

      ≤±1.5℃

      

      

      Smoke temperature

      

      0 ~ 500℃

      

      1℃

      

      ≤±3℃

      

      

      atmospheric pressure

      

      70~130kPa

      

      0.1 kPa

      

      ≤±2.5 %

      

      

      humidity ratio

      

      (0~60)%

      

      0.1%

      

      ≤±1.5%

      

      

      O2 (optional)

      

      0 ~ 30%

      

      0.1%

      

      Indication error: ≤± 2%;

      Repeatability: ≤ 2%;

      Response time: ≤ 90s;

      Stability: The displayed value changes by ≤ 5% within 1 hour.

      

      

      SO2 (optional)

      

      0~5700 mg/m3

      

      1 mg/m3

      

      

      NO2 (optional)

      

      0~200 mg/m3

      

      1 mg/m3

      

      

      NO (optional)

      

      0~1300 mg/m3

      

      1 mg/m3

      

      

      CO (optional)

      

      0~5000 mg/m3

      

      1 mg/m3

      

      

      CO2 (optional)

      

      0-30%

      

      0.01%

      

      

      H2S (optional)

      

      0-300 mg/m3

      

      1 mg/m3

      

      

      

      Sampling pump load capacity

      

      ≥ 50 L/min (when resistance is -20kPa)

      

      

      Data storage capability

      

      One million sets

      

      

      Sampling volume

      

      999999 .9 L

      

      0.1 L

      

      ≤±2.5%

      

      

      Overall dimensions

      

      335×145×280 mm

      

      Instrument noise

      

      <65dB(A)

      

      Total weight

      

      About 8.0 kg

      

      power consumption

      

      <100 W

      

      Thermal Holding Environmental Protection RC-60E Smoke and Dust Automatic Tester

    AfterSalesService :

    Key words:
    • Smoke and dust automatic testing instrument