Thermal Holding Environmental Protection RC-80D Smoke and Gas Tester Microcomputer Smoke and Gas Analyzer National Standard Smoke and Gas Tester
Thermal Holding Environmental Protection RC-80D Smoke and Gas Tester Microcomputer Smoke and Gas Analyzer National Standard Smoke and Gas Tester

Thermal Holding Environmental Protection RC-80D Smoke and Gas Tester Microcomputer Smoke and Gas Analyzer National Standard Smoke and Gas Tester

Category:

Instrumentation/Gas analyzer/flue gas analyzer

Model:

RC-60E

Brand:

Thermal Holding Environmental Protection

model:

RC-60E

resolution:

1PPM

measurement object:

flue gas

measurement range:

5000ppm

power supply voltage:

two hundred and twenty

type:

portable

display mode:

electron

structural style :

handheld

Processing & Customization:

yes

gas flow rate:

five hundred

Specifications:

handheld

manufacturer:

Thermal Holding Environmental Protection

Retail Price

25,000.00USD


重量

kg

  • Product Description
  • model

    RC-60E

    resolution

    1PPM

    measurement object

    flue gas

    measurement range

    5000ppm

    power supply voltage

    two hundred and twenty

    type

    portable

    display mode

    electron

    structural style

    handheld

    Processing & Customization

    yes

    gas flow rate

    five hundred

    Specifications

    handheld

    manufacturer

    Thermal Holding Environmental Protection

    Description :

    Thermal Holding Environmental Protection RC-80D Smoke and Gas Tester Microcomputer Smoke and Gas Analyzer National Standard Smoke and Gas Tester

      The automatic smoke and dust testing instrument has always been a popular product in the past few years of my career. When customers choose a product, they may consider factors such as brand, quality, after-sales service, price, and even the salesperson's understanding of the product, which is crucial for customers to choose your product.

      In my opinion, in the current environment, product quality and after-sales service are fundamental and unshakable. Furthermore, sales personnel's awareness and familiarity with the product, their understanding of the on-site environment, and whether they can truly help customers solve problems are particularly important. That's why I'm here.

      1、 Execution standards

      HJ 57-2017 "Determination of Sulfur Dioxide in Fixed Source Waste Gas by Fixed Point Electrolysis Method"

      HJ 836-2017 "Determination of Low Concentration Particulate Matter in Fixed Source Waste Gas by Weight Method"

      GB/T 16157-1996 "Determination of particulate matter and sampling methods for gaseous pollutants in exhaust from stationary sources"

      HJ/T 48-1999 "Technical Conditions for Dust Samplers" JJG 968-2002 "Smoke Analyzer"

      HJ 693-2014 "Determination of Nitrogen Oxides in Fixed Source Waste Gas by Potentiometric Electrolysis Method"

      HJ 973-2018 "Determination of CO in Fixed Source Waste Gas by Potentiometric Electrolysis Method"

      JJG 680-2007 "Smoke and Dust Sampler" JJG 518-199 "Verification Regulations for Pitot Tubes"

      IIThermal Holding Environmental Protection RC-80D Smoke and Gas Tester Microcomputer Smoke and Gas Analyzer National Standard Smoke and Gas Testerpurpose

      The RC-80D high flow automatic smoke and dust testing instrument adopts pitot tube constant velocity sampling and weight method to measure the mass concentration of smoke and dust, and positioning electrolysis method or optical principle to determine the concentration of harmful gases in the flue. It can measure parameters such as smoke, moisture content, flow rate, dynamic pressure, static pressure, smoke temperature, oil fume, and smoke (such as O2, SO2, NO, NO2, CO, CO2, H2S). This instrument is equipped with a low concentration sampling tube for constant velocity sampling of low concentration particulate matter. The mass concentration of low concentration particulate matter is measured by weighing the filter membrane (filter cartridge). It can be widely used in environmental monitoring, labor protection, industrial hygiene, factories and mining enterprises to sample particulate matter and harmful gas concentrations in pipeline pollution sources. It can also be applied to evaluate and calibrate the accuracy of continuous flue gas measurement instruments.

      3、 Performance characteristics

      1. One machine is versatile and can measure smoke, exhaust gas, oil fume, asphalt smoke, and real-time read parameters such as moisture content, flow rate, dynamic pressure, static pressure, smoke temperature, and exhaust gas (such as O2, SO2, NO, NO2, CO, CO2, H2S).

      2. The optional RC-88R series low concentration smoke sampling tube can measure the mass concentration of low concentration smoke by constant velocity sampling and overall weighing of the filter membrane. Conventional concentration constant velocity sampling and filter weighing methods can also be used to measure the mass concentration of conventional concentration particulate matter.

      3. Adopting a high load, low noise, and high flow pump, the flow rate can reach 110L/min.

      4. The entire instrument adopts a one-time molding mold ABS protective box, which has the advantages of small size, sturdy structure, and beautiful appearance.

      5. Optional multifunctional oil fume sampling tube for oil fume sampling and analysis. Optional intelligent flue gas preprocessor can filter, heat and dehydrate the flue gas in the flue, making the measurement data more accurate.

      6. Optional options include titanium alloy dust sampling tube, sulfur spray sampling tube, salt spray sampling tube, chlorine hydrogen sampling tube, fluoride sampling tube, heavy metal sampling tube, semi volatile organic compound sampling gun, etc.

      7. The host adopts a high-performance microcontroller embedded structure and a microcomputer data direct reading software design for querying, printing, and automatic storage of sampled data. The sampling results can be directly printed through the RS232 interface, or exported using a USB flash drive for computer storage or printing. The instrument host can automatically recognize the size of the USB flash drive for convenient data storage.

      8. Automatically remember the monitoring parameters entered last time, prioritize use for the next power on, achieve quick one click sampling, and can also save monitoring parameters for arbitrary retrieval and use.

      9. The unique three in one design of drying, filtering, and anti backflow suction in the steam water separator can efficiently dry moisture, filter dust, and reduce the impact of backflow suction on flow rate, achieving long-term operation without cleaning.

      10. Wide temperature LCD display, adjustable backlight and brightness, Chinese human-machine dialogue menu display, illustrated with text, simple and clear. Users can directly operate with the rich online operation prompts of the instrument. The three key backlight and contrast adjustment are simple and clear.

      11. Multi level optoelectronic isolation, multi CPU fault-tolerant structure, each CPU monitors the working status of each other, alarms in case of errors, and overcomes electrostatic interference and breakdown. 12. Equipped with a visual front plug-in high-efficiency gas water separator that can be disassembled separately, effectively filtering out the impact of water and gas on pipeline and flue gas measurement results.

      13. Automatically adjust parameters such as temperature and pressure, and standard condition data can be directly read out.

      14. Linear calibration of various parameters of the instrument can be directly performed through a waterproof keyboard. Password must be entered for instrument maintenance and calibration, and permission management is also available to ensure the safety of all instrument parameters.

      15. Using imported pressure sensors and imported electrochemical sensors for measurement results is more accurate. The integrated design of electrochemical sensors and signal modules includes temperature and linear compensation as well as cross interference correction functions to ensure testing accuracy.

      16. Adopting corrosion-resistant high flow rate adjustable speed smoke sampling pump and electronic flowmeter, with fast response and high tracking efficiency. The flue gas pipeline adopts a tetrachloroyiene pipeline without adsorption, and uses an electronic flowmeter for constant current sampling to ensure the accuracy of measurement results.

      17. Equipped with power outage protection function, data is saved in case of AC power outage, and sampling is automatically restored and deducted during the sampling process in case of AC incoming call

      The power outage time can be queried by users.

      18. The instrument is a dual-purpose AC/DC type, equipped with a built-in large capacity imported lithium battery cell. It can work in situations without AC power supply and has a continuous working time of more than 3 hours (with filter cartridge, connecting tube, 40L, 15kpa).

      19. It can store various parameters of the system settings, facilitate user use, directly access system settings or sampling settings, and has system recovery function and file batch and selective deletion function.

      4、 Technical parameters

    Thermal Holding Environmental Protection RC-80D Smoke and Gas Tester Microcomputer Smoke and Gas Analyzer National Standard Smoke and Gas Tester

    AfterSalesService :

    Key words:
    • Smoke and dust testing instrument