Boda collagen suture (endoscopic snare suture)
Category:
Medical maintenance/Medical suture materials and adhesives/Medical absorbable suture
Model:
1/0/2-0/3-0/4-0/5-0
Brand:
Boda
Retail Price
Negotiable
重量
kg
- Product Description
-
Description :
Manufacturer:Shandong Boda Medical Supplies Co., Ltd
Production address: East end of Dan Dang Road, Dan County, Heze, Shandong Province
Mobile/WeChat:
Purpose: Mainly used for tissue suturing in general surgery, gynecology, and obstetrics and gynecology surgeries.

Shandong Boda Medical Supplies Co., Ltd
Address: East end of Dan Dang Road, Dan County, Heze City, Shandong Province
Lv Jia's mobile phone/WeChat:
Absorbable surgical suture(collagenEndoscopic snare line/Without needles)Product Introduction
Brand: Bangda
Specifications1 #, wire length: 60cm, pipe diameter: 30cm, coil diameter max: 8cm
purposeTheScope of Application:Applicable toThe ligation of tissues such as bile ducts, gallbladder, uterine fibroids, uterine cysts, fallopian tubes, appendix, and intestine during laparoscopic minimally invasive surgery, and the ligation of tissues during open surgery.
packaging1 piece/pack, 20 packs/box, 6 boxes/box
Advantage:Flexible and convenient, easy to handle, free from tangling, expands when in contact with water, and has a stronger knot structure
Product Features
Made from natural raw materials, it has the characteristics of strong tensile strength, firm knotting, biocompatibility, absorbability by the body, and minimal toxic side effects.
Product Introduction
Bangda brand "absorbable surgical suture" (endoscopic snare suture) was independently developed and researched by our company in 2000 under the guidance of Professor Liu Yanmin, a domestic authority in endoscopic surgery and medical technology training instructor. In 2004, this product obtained the national utility model patent and filled the gap in this type of product in China at that time.
The body of the "absorbable surgical suture" (endoscope snare suture) from Bangda brand is made of natural materials processed by wet spinning technology, which has the advantages of strong tensile strength, good biocompatibility, minimal toxic side effects, and firm knotting. The product is widely used for ligation of appendiceal, gallbladder, uterine fibroids, fallopian tubes, and other surgical enlarged tumor tissues in endoscopic surgery. It has been clinically used for more than 10 years with good response and has received high praise.
Product Features
Banda brand "absorbable surgical suture" (endoscopic snare suture) has good biocompatibility due to its material and tissue structure being similar to that of human tissue, which is conducive to tissue absorption and has extremely low rejection. The collagen component in the thread has the characteristic of swelling when it comes into contact with water (bodily fluids in the human body cavity). Therefore, after using "absorbable surgical sutures" for endoscopic ligation, the knot gradually expands after being soaked in body fluids, making the knot more firm and avoiding adverse events such as intestinal leakage and bile leakage that often occur during endoscopic ligation surgery, thereby reducing surgical risks. The absorption period is 3 months, starting from 7 days and fully absorbed within 90 days.
Application scope: Suitable for ligation under minimally invasive abdominal surgery, such as ligation of uterine fibroids, gallbladder, appendix, fallopian tubes, and other surgical enlarged tumor tissues. 1. Chitosan: It has antibacterial properties, can resist microbial infections, induce tissue regeneration, accelerate wound healing, and does not cause any inflammatory reactions in tissues. Collagen: It has hemostatic and repairing functions, as well as biological absorption and cell adhesion, promoting the formation of new cells and epithelial cells. 2. Due to the excellent biocompatibility of chitosan and collagen materials, the product has low antigenicity and good compatibility with human tissues. 3. Through the automatic coordination of enzymes and body fluids for absorption, the absorption period is stable and ultimately fully absorbed by the human body; (Non toxic side effects) 4. Single stranded wire: no gaps between strands. 5. The auxiliary tube is made of non-toxic materials, with a smooth surface and good elasticity of the tube body, making the surgical operation transition smooth. 6. Easy to operate, convenient, safe, and reliable.
Specification: Wire length: 60cm, pipe diameter: 30cm, coil diameter max: 8cm
Other commonly used names: Medical absorbable suture thread, collagen thread, endoscope sheath suture, knot free snare suture, knot free endoscope sheath suture
Banda endoscopic snare wire, appendicitis endoscopic snare wire, laparoscopic ligature wire, medical ligature wireAbsorbable surgical suture(collagenEndoscopic snare line/Without needles)
BodaAbsorbable surgical suture(Knot freeEndoscopic snare line
Comparison of commonly used endoscopic surgical ligation materials
Banda brand absorbable surgical suture”
Absorbable chemical synthesis line
Titanium clip (absorbable clip made of other materials)
Biocompatibility
Made from natural materials with a structure similar to human tissue, it has good biocompatibility.
Made of chemical synthetic materials, with poor biocompatibility.
Made of titanium metal, it is basically incompatible with human tissue structure.
Human body rejection
The material of the thread body has good compatibility with human tissue, which is conducive to tissue absorption and has extremely low rejection by human tissue.
The material of the thread can be absorbed by tissues, but its chemical synthesis characteristics result in incomplete absorption, leading to rejection by human tissues.
Made of titanium metal, it cannot be absorbed by human tissues, has high excretion in the human body, and produces metal ions in the human body.
Ligation and knotting
Complete ligation ensures even force distribution at all points of the tissue. After knotting, the knot swells when it encounters bodily fluids, making it more secure and preventing accidents such as intestinal and biliary leakage.
Complete ligation ensures even force distribution at all points of the tissue, and the structure has no expansion characteristics, resulting in loosening and causing adverse accidents such as intestinal leakage and bile leakage.
Alligator ligation can cause uneven stress on various points of the tissue, which can easily lead to intestinal and biliary leakage accidents. It is difficult to clamp larger lesions and has limitations in use.
Operation usage
The catheter is introduced, and the thread material is relatively hard, so it will not rotate when encountering body cavity fluid, making it easy to ligate the tissue with a loop.
The catheter is introduced, and the material of the thread body is relatively soft, which may cause a twisting phenomenon in the body cavity fluid, which is not conducive to the ligation of tissue with the sheath.
The introduction of clamping equipment poses a risk of cavity detachment or loss of clamping.
Sterilization method
Gamma ray sterilization results in zero bacterial residue and no other residual substances, avoiding the occurrence of aseptic inflammation.
Ethylene oxide sterilization has a chance of bacterial residue, but this sterilization method may leave other substances and cause aseptic inflammation.
It depends on the material used.
AfterSalesService :
Key words:- Collagen suture thread